Show simple item record

dc.contributor.authorYagi, Yukako
dc.contributor.authorGilbertson, John R
dc.date.accessioned2011-11-22T16:13:48Z
dc.date.issued2008
dc.identifier.citationYagi, Yukako, and John R. Gilbertson. 2008. The importance of optical optimization in whole slide imaging (WSI) and digital pathology imaging. Diagnostic Pathology 3(Suppl 1): S1.en_US
dc.identifier.issn1746-1596en_US
dc.identifier.urihttp://nrs.harvard.edu/urn-3:HUL.InstRepos:5350701
dc.description.abstractIn the last 10 years, whole slide imaging (WSI) has seen impressive progress not only in image quality and scanning speed but also in the variety of systems available to pathologists. However, we have noticed that most systems have relatively simple optics axes and rely on software to optimize image quality and colour balance. While much can be done in software, this study examines the importance of optics, in particular optical filters, in WSI. Optical resolution is a function of the wavelength of light used and the numerical aperture of the lens system (Resolution = (f) wavelength/2 NA). When illumining light is not conditioned correctly with filters, there is a tendency for the wavelength to shift to longer values (more red) because of the characteristics of the lamps in common use. Most microscopes (but remarkably few WSI devices) correct for this with ND filter for brightness and Blue filter (depends on the light source) for colour correction. Using H&E slides research microscopes (Axiophot, Carl Zeiss MicroImaging, Inc. NY. Eclipse 50i., Nikon Inc. NY) at 20×, an attached digital camera (SPOT RT741 Slider Color, Diagnosis Instruments, MI USA), and a filter set, we examined the effect of filters and software enhancement on digital image quality. The focus value (as evaluated by focus evaluation software developed in house and SPOT imaging Software v4.6) was used as a proxy for image quality. Resolution of tissue features was best with the use of both the Blue and ND filters (in addition to software enhancement). Images without filters but with software enhancement while superficially good, lacked some details of specimen morphology and were unclear compared with the images with filters. The results indicate that the appropriate use of optical filters could measurably improve the appearance and resolution of WSI images.en_US
dc.language.isoen_USen_US
dc.publisherBioMed Centralen_US
dc.relation.isversionofdoi:10.1186/1746-1596-3-S1-S1en_US
dc.relation.hasversionhttp://www.ncbi.nlm.nih.gov/pmc/articles/PMC2500117/pdf/en_US
dash.licenseLAA
dc.titleThe Importance of Optical Optimization in Whole Slide Imaging (WSI) and Digital Pathology Imagingen_US
dc.typeJournal Articleen_US
dc.description.versionVersion of Recorden_US
dc.relation.journalDiagnostic Pathologyen_US
dash.depositing.authorYagi, Yukako
dc.date.available2011-11-22T16:13:48Z
dash.affiliation.otherHMS^Pathologyen_US
dc.identifier.doi10.1186/1746-1596-3-S1-S1*
dash.contributor.affiliatedYagi, Yukako
dash.contributor.affiliatedGilbertson, John R


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record