| dc.description.abstract |
The combination of simple Electrochemical Micro-Paper-based Analytical Devices (E\(\mu\)PADs) with commercially available glucometers allows rapid, quantitative electrochemical analysis of a number of compounds relevant to human health (e.g., glucose, cholesterol, lactate, and alcohol) in blood or urine. |
en_US |
| dc.description.sponsorship |
Chemistry and Chemical Biology |
en_US |
| dc.language.iso |
en_US |
en_US |
| dc.publisher |
Royal Society of Chemistry |
en_US |
| dc.relation.isversionof |
doi:10.1039/c0lc00237b |
en_US |
| dash.license |
OAP |
|
| dc.subject |
glucometers |
en_US |
| dc.subject |
microfluidics |
en_US |
| dc.subject |
electrochemical sensing |
en_US |
| dc.subject |
medical diagnostics |
en_US |
| dc.subject |
blood glucose |
en_US |
| dc.subject |
blood glucose self-monitoring |
en_US |
| dc.subject |
cholesterol |
en_US |
| dc.subject |
electrochemical techniques |
en_US |
| dc.subject |
ethanol |
en_US |
| dc.subject |
food analysis |
en_US |
| dc.subject |
humans |
en_US |
| dc.subject |
lactic acid |
en_US |
| dc.subject |
linear models |
en_US |
| dc.subject |
microfluidic analytical techniques |
en_US |
| dc.subject |
paper |
en_US |
| dc.title |
Integration of paper-based microfluidic devices with commercial electrochemical readers |
en_US |
| dc.type |
Journal Article |
en_US |
| dc.description.version |
Accepted Manuscript |
en_US |
| dc.relation.journal |
Lab on a Chip |
en_US |
| dash.depositing.author |
Whitesides, George M.
|
|
| dc.date.available |
2012-11-06T17:23:58Z |
|
Files in this item
This item appears in the following Collection(s)
-
FAS Scholarly Articles [5127]
Peer reviewed scholarly articles from the Faculty of Arts and Sciences of Harvard University
Show simple item record
Contact administrator regarding this item (to report mistakes or request changes)