Now showing items 1-2 of 2

    • Low Incidence of Chest Wall Pain with a Risk-Adapted Lung Stereotactic Body Radiation Therapy Approach Using Three or Five Fractions Based on Chest Wall Dosimetry 

      Coroller, Thibaud P.; Mak, Raymond H.; Lewis, John H.; Baldini, Elizabeth H.; Chen, Aileen B.; Colson, Yolonda L.; Hacker, Fred L.; Hermann, Gretchen; Kozono, David; Mannarino, Edward; Molodowitch, Christina; Wee, Jon O.; Sher, David J.; Killoran, Joseph H. (Public Library of Science, 2014)
      Purpose To examine the frequency and potential of dose-volume predictors for chest wall (CW) toxicity (pain and/or rib fracture) for patients receiving lung stereotactic body radiotherapy (SBRT) using treatment planning ...
    • Volumetric CT-based segmentation of NSCLC using 3D-Slicer 

      Velazquez, Emmanuel Rios; Parmar, Chintan; Jermoumi, Mohammed; Mak, Raymond H.; van Baardwijk, Angela; Fennessy, Fiona M.; Lewis, John H.; De Ruysscher, Dirk; Kikinis, Ron; Lambin, Philippe; Aerts, Hugo J. W. L. (Nature Publishing Group, 2013)
      Accurate volumetric assessment in non-small cell lung cancer (NSCLC) is critical for adequately informing treatments. In this study we assessed the clinical relevance of a semiautomatic computed tomography (CT)-based ...