  • Publication

    Microfluidic Chip for Molecular Amplification of Influenza A RNA in Human Respiratory Specimens

    (Public Library of Science, 2012) Cao, Qingqing; Mahalanabis, Madhumita; Chang, Jessie; Carey, Brendan; Hsieh, Christopher; Stanley, Ahjegannie; Odell, Christine A.; Mitchell, Patricia; Klapperich, Catherine M.; Pollock, Nira; Feldman, James

    A rapid, low cost, accurate point-of-care (POC) device to detect influenza virus is needed for effective treatment and control of both seasonal and pandemic strains. We developed a single-use microfluidic chip that integrates solid phase extraction (SPE) and molecular amplification via a reverse transcription polymerase chain reaction (RT-PCR) to amplify influenza virus type A RNA. We demonstrated the ability of the chip to amplify influenza A RNA in human nasopharyngeal aspirate (NPA) and nasopharyngeal swab (NPS) specimens collected at two clinical sites from 2008–2010. The microfluidic test was dramatically more sensitive than two currently used rapid immunoassays and had high specificity that was essentially equivalent to the rapid assays and direct fluorescent antigen (DFA) testing. We report 96% (CI 89%,99%) sensitivity and 100% (CI 95%,100%) specificity compared to conventional (bench top) RT-PCR based on the testing of n = 146 specimens (positive predictive value = 100%(CI 94%,100%) and negative predictive value = 96%(CI 88%,98%)). These results compare well with DFA performed on samples taken during the same time period (98% (CI 91%,100%) sensitivity and 96%(CI 86%,99%) specificity compared to our gold standard testing). Rapid immunoassay tests on samples taken during the enrollment period were less reliable (49%(CI 38%,61%) sensitivity and 98%(CI 98%,100%) specificity). The microfluidic test extracted and amplified influenza A RNA directly from clinical specimens with viral loads down to 103 copies/ml in 3 h or less. The new test represents a major improvement over viral culture in terms of turn around time, over rapid immunoassay tests in terms of sensitivity, and over bench top RT-PCR and DFA in terms of ease of use and portability.

  • Publication

    Deadly Diving? Physiological and Behavioural Management of Decompression Stress in Diving Mammals

    (The Royal Society, 2011) Hooker, S. K.; Fahlman, A.; Aguilar de Soto, N.; Bernaldo de Quirós, Y.; Brubakk, A. O.; Costidis, A. M.; Dennison, S.; Falke, K. J.; Fitz-Clarke, J. R.; Garner, M. M.; Houser, D. S.; Jepson, P. D.; Kvadsheim, P. H.; Rowles, T. K.; Van Bonn, W.; Weathersby, P. K.; Weise, M. J.; Tyack, P. L.; Moore, M. J.; Costa, D. P.; Fernandez, A.; Ferrigno, Massimo; Ketten, Darlene; Madsen, P. T.; Pollock, Nira; Rotstein, D. S.; Simmons, S. E.; Williams, T. M.

    Decompression sickness (DCS; ‘the bends’) is a disease associated with gas uptake at pressure. The basic pathology and cause are relatively well known to human divers. Breath-hold diving marine mammals were thought to be relatively immune to DCS owing to multiple anatomical, physiological and behavioural adaptations that reduce nitrogen gas (N(_2)) loading during dives. However, recent observations have shown that gas bubbles may form and tissue injury may occur in marine mammals under certain circumstances. Gas kinetic models based on measured time-depth profiles further suggest the potential occurrence of high blood and tissue N(_2) tensions. We review evidence for gas-bubble incidence in marine mammal tissues and discuss the theory behind gas loading and bubble formation. We suggest that diving mammals vary their physiological responses according to multiple stressors, and that the perspective on marine mammal diving physiology should change from simply minimizing N(_2) loading to management of the N(_2) load. This suggests several avenues for further study, ranging from the effects of gas bubbles at molecular, cellular and organ function levels, to comparative studies relating the presence/absence of gas bubbles to diving behaviour. Technological advances in imaging and remote instrumentation are likely to advance this field in coming years.

  • Publication

    Field Evaluation of a Prototype Paper-Based Point-of-Care Fingerstick Transaminase Test

    (Public Library of Science, 2013) Pollock, Nira; McGray, Sarah; Colby, Donn J.; Noubary, Farzad; Nguyen, Huyen; Nguyen, The Anh; Khormaee, Sariah; Jain, Sidhartha; Hawkins, Kenneth; Kumar, Shailendra; Rolland, Jason P.; Beattie, Patrick D.; Chau, Nguyen V.; Quang, Vo M.; Barfield, Cori; Tietje, Kathy; Steele, Matt; Weigl, Bernhard H.

    Monitoring for drug-induced liver injury (DILI) via serial transaminase measurements in patients on potentially hepatotoxic medications (e.g., for HIV and tuberculosis) is routine in resource-rich nations, but often unavailable in resource-limited settings. Towards enabling universal access to affordable point-of-care (POC) screening for DILI, we have performed the first field evaluation of a paper-based, microfluidic fingerstick test for rapid, semi-quantitative, visual measurement of blood alanine aminotransferase (ALT). Our objectives were to assess operational feasibility, inter-operator variability, lot variability, device failure rate, and accuracy, to inform device modification for further field testing. The paper-based ALT test was performed at POC on fingerstick samples from 600 outpatients receiving HIV treatment in Vietnam. Results, read independently by two clinic nurses, were compared with gold-standard automated (Roche Cobas) results from venipuncture samples obtained in parallel. Two device lots were used sequentially. We demonstrated high inter-operator agreement, with 96.3% (95% C.I., 94.3–97.7%) agreement in placing visual results into clinically-defined “bins” (<3x, 3–5x, and >5x upper limit of normal), >90% agreement in validity determination, and intraclass correlation coefficient of 0.89 (95% C.I., 0.87–0.91). Lot variability was observed in % invalids due to hemolysis (21.1% for Lot 1, 1.6% for Lot 2) and correlated with lots of incorporated plasma separation membranes. Invalid rates <1% were observed for all other device controls. Overall bin placement accuracy for the two readers was 84% (84.3%/83.6%). Our findings of extremely high inter-operator agreement for visual reading–obtained in a target clinical environment, as performed by local practitioners–indicate that the device operation and reading process is feasible and reproducible. Bin placement accuracy and lot-to-lot variability data identified specific targets for device optimization and material quality control. This is the first field study performed with a patterned paper-based microfluidic device and opens the door to development of similar assays for other important analytes.

  • Publication

    A Paper-Based Multiplexed Transaminase Test for Low-Cost, Point-of-Care Liver Function Testing

    (American Association for the Advancement of Science (AAAS), 2012) Pollock, Nira; Rolland, Jason P.; Kumar, Shailendra; Beattie, Patrick Daniel; Jain, Sidhartha; Noubary, Farzad; Wong, Vicki L.; Pohlmann, Rebecca; Ryan, Una S.; Whitesides, George

    In developed nations, monitoring for drug-induced liver injury through serial measurements of serum transaminases [aspartate aminotransferase (AST) and alanine aminotransferase (ALT)] in at-risk individuals is the standard of care. Despite the need, monitoring for drug-related hepatotoxicity in resource-limited settings is often limited by expense and logistics, even for patients at highest risk. This article describes the development and clinical testing of a paper-based, multiplexed microfluidic assay designed for rapid, semiquantitative measurement of AST and ALT in a fingerstick specimen. Using 223 clinical specimens obtained by venipuncture and 10 fingerstick specimens from healthy volunteers, we have shown that our assay can, in 15 min, provide visual measurements of AST and ALT in whole blood or serum, which allow the user to place those values into one of three readout “bins” [<3× upper limit of normal (ULN), 3 to 5× ULN, and >5× ULN, corresponding to tuberculosis/HIV treatment guidelines] with >90% accuracy. These data suggest that the ultimate point-of-care fingerstick device will have high impact on patient care in low-resource settings.

  • Publication

    Discovery of a unique Mycobacterium tuberculosis protein through proteomic analysis of urine from patients with active tuberculosis

    (Elsevier, 2017) Pollock, Nira; Dhiman, Rakesh; Daifalla, Nada; Farhat, Maha; Campos-Neto, Antonio

    Identification of pathogen-specific biomarkers present in patients' serum or urine samples can be a useful diagnostic approach. In efforts to discover Mycobacterium tuberculosis (Mtb) biomarkers we identified by mass spectroscopy a unique 21-mer Mtb peptide sequence (VVLGLTVPGGVELLPGVALPR) present in the urines of TB patients from Zimbabwe. This peptide has 100% sequence homology with the protein TBCG_03312 from the C strain of Mtb (a clinical isolate identified in New York, NY, USA) and 95% sequence homology with Mtb oxidoreductase (MRGA423_21210) from the clinical isolate MTB423 (identified in Kerala, India). Alignment of the genes coding for these proteins show an insertion point mutation relative to Rv3368c of the reference H37Rv strain, which generated a unique C-terminus with no sequence homology with any other described protein. Phylogenetic analysis utilizing public sequence data shows that the insertion mutation is apparently a rare event. However, sera from TB patients from distinct geographical areas of the world (Peru, Vietnam, and South Africa) contain antibodies that recognize a purified recombinant C-terminus of the protein, thus suggesting a wider distribution of isolates that produce this protein.