Person: Edelman, Elazer
Email Address
AA Acceptance Date
Birth Date
Research Projects
Organizational Units
Job Title
Last Name
First Name
Name
Search Results
Publication Constraining OCT with Knowledge of Device Design Enables High Accuracy Hemodynamic Assessment of Endovascular Implants
(Public Library of Science, 2016) O’Brien, Caroline C.; Kolandaivelu, Kumaran; Brown, Jonathan; Lopes, Augusto C.; Kunio, Mie; Kolachalama, Vijaya B.; Edelman, ElazerBackground: Stacking cross-sectional intravascular images permits three-dimensional rendering of endovascular implants, yet introduces between-frame uncertainties that limit characterization of device placement and the hemodynamic microenvironment. In a porcine coronary stent model, we demonstrate enhanced OCT reconstruction with preservation of between-frame features through fusion with angiography and a priori knowledge of stent design. Methods and Results: Strut positions were extracted from sequential OCT frames. Reconstruction with standard interpolation generated discontinuous stent structures. By computationally constraining interpolation to known stent skeletons fitted to 3D ‘clouds’ of OCT-Angio-derived struts, implant anatomy was resolved, accurately rendering features from implant diameter and curvature (n = 1 vessels, r2 = 0.91, 0.90, respectively) to individual strut-wall configurations (average displacement error ~15 μm). This framework facilitated hemodynamic simulation (n = 1 vessel), showing the critical importance of accurate anatomic rendering in characterizing both quantitative and basic qualitative flow patterns. Discontinuities with standard approaches systematically introduced noise and bias, poorly capturing regional flow effects. In contrast, the enhanced method preserved multi-scale (local strut to regional stent) flow interactions, demonstrating the impact of regional contexts in defining the hemodynamic consequence of local deployment errors. Conclusion: Fusion of planar angiography and knowledge of device design permits enhanced OCT image analysis of in situ tissue-device interactions. Given emerging interests in simulation-derived hemodynamic assessment as surrogate measures of biological risk, such fused modalities offer a new window into patient-specific implant environments.
Publication Sex differences in the outcomes of stent implantation in mini-swine model
(Public Library of Science, 2018) Kunio, Mie; Wong, Gee; Markham, Peter M.; Edelman, ElazerSex-related differences have been noted in cardiovascular anatomy, pathophysiology, and treatment responses, yet we continued to drive evaluation of vascular device development in animal models without consideration of animal sex. We aimed to understand sex-related differences in the vascular responses to stent implantation by analyzing the pooled data of endovascular interventions in 164 Yucatan mini-swine (87 female, 77 male). Bare metal stents (BMS) or drug-eluting stents (DES) were implanted in 212 coronary arteries (63 single BMS implantation, 68 single DES implantation, 33 overlapped BMS implantation, and 48 overlapped DES implantation). Histomorphological parameters were evaluated from vascular specimens at 3–365 days after stent implantation and evaluated values were compared between female and male groups. While neointima formation at all times after implantation was invariant to sex, statistically significant differences between female and male groups were observed in injury, inflammation, adventitial fibrosis, and neointimal fibrin deposition. These differences were observed independently, i.e., for different procedure types and at different follow-up timings. Only subtle temporal sex-related differences were observed in extent and timing of resolution of inflammation and fibrin clearance. These subtle sex-related differences may be increasingly important as interventional devices meld novel materials that erode and innovations in drug delivery. Erodible materials may act differently if inflammation has a different temporal sequence with sex, and drug distribution after balloon or stent delivery might be different if the fibrin clearance speaks to different modes of pharmacokinetics in male and female swine.