Person:

Abelson, Mark

Loading...
Profile Picture

Email Address

AA Acceptance Date

Birth Date

Research Projects

Organizational Units

Job Title

Last Name

Abelson

First Name

Mark

Name

Abelson, Mark

Search Results

Now showing 1 - 2 of 2
  • Publication

    Technical and clinical validation of the Allergen BioCube® for timothy grass

    (John Wiley and Sons Inc., 2017) Angjeli, Endri; Gomes, Paul; Lane, Keith J.; Stein, Linda; Abelson, Mark

    Abstract Introduction: Field studies for allergic rhinitis (AR) commonly have inconsistent allergen concentrations and subject exposure patterns due to varying environmental conditions and subject behaviors. A technical and clinical validation study was conducted for the Allergen BioCube® using timothy grass to confirm uniform allergen concentration and clinically relevant subject symptom responses. Methods: Allergen concentrations were verified by laser particle counts. Subjects (N = 14) with positive skin test reactions and no symptoms at screening received four 3‐h timothy grass exposures in the BioCube over consecutive days. Subjects evaluated nasal itching, sneezing, rhinorrhea, and nasal congestion while in the BioCube; Total Nasal Symptom Score (TNSS) was computed. Peak Nasal Inspiratory Flow (PNIF), Peak Expiratory Flow Rate (PEFR), sIgE blood tests, and Nasal Inflammation Score (NIS) were assessed. A correlation analysis was conducted for mean sIgE, skin test, and TNSS. Results: Uniform timothy grass concentrations were achieved in the BioCube, both spatially and temporally, at all subject positions. Mean TNSS increased substantially from pre‐exposure levels (0.36 ± 0.74 to 1.86 ± 2.14) to maximums of 7.07 ± 2.76 at 1.5 h and 6.71 ± 2.70 at 3 h BioCube exposure. Twelve (86%) subjects had TNSS increases ≥6 units. PNIF decreased 12–24% from baseline at 3‐h BioCube exposure. NIS increased (baseline = 0) to 3.7 (maximum score = 4). A low/moderate correlation (r = 0.485) occurred between mean sIgE blood levels and mean skin tests; neither sIgE or skin tests correlated with mean TNSS. However, subjects with high skin test scores or positive blood IgE tended to also have higher TNSS. Conclusions: The Allergen BioCube achieved technical and clinical validation for uniform timothy grass concentration and clinically meaningful AR sign and symptom responses. The Allergen BioCube can be used to assess the efficacy of therapies for reduction of AR signs and symptoms resulting from grass exposure.

  • Publication

    Technical and clinical validation of an environmental exposure unit for ragweed

    (Dove Medical Press, 2016) Gomes, Paul J; Lane, Keith J; Angjeli, Endri; Stein, Linda; Abelson, Mark

    Background: Allergic rhinitis is a common condition, with ragweed pollen one of the more prevalent aeroallergens. Environmental exposure units such as the Allergen BioCube® are valuable models for clinical allergy studies. A study was conducted to validate the Allergen BioCube for uniform ragweed pollen concentrations and clinically relevant sign and symptom responses to ragweed exposure. Methods: Ragweed pollen concentrations were measured on 3 consecutive days in the Allergen BioCube and verified by Rotorod collection and continuous laser particle count measurements. Subjects (N=10) were exposed to ragweed pollen in the BioCube for 3 hours per day for 3 consecutive days. Subjects assessed their nasal itching, sneezing, rhinorrhea, and nasal congestion during each BioCube exposure; total nasal symptom score was computed. Peak nasal inspiratory flow was also assessed during BioCube exposure. Results: Uniform ragweed pollen concentrations were obtained throughout each of the 3-hour testing periods in the Allergen BioCube, both spatially and temporally, at all subject positions, with a low mean standard deviation of 10%. Pronounced increases in mean total nasal symptom scores (6.7±0.94 to 7.6±0.86, last 90 minutes of exposure) occurred for all three BioCube ragweed pollen exposure visits. Mean peak nasal inspiratory flow decreased 24% at 3 hours of BioCube exposure on Day 3. No safety issues of concern occurred in this study. Conclusion: The Allergen BioCube achieved technical and clinical validation for ragweed allergen. Ragweed pollen concentration was uniform both temporally and spatially. Allergic rhinitis signs and symptoms were induced in subjects during exposure to ragweed in the BioCube at clinically meaningful levels for allergy studies.