Publication:

Assessment of regional pulmonary blood flow using 68Ga-DOTA PET

Loading...
Thumbnail Image

Open/View Files

Date

2017

Journal Title

Journal ISSN

Volume Title

Publisher

Springer Berlin Heidelberg
The Harvard community has made this article openly available. Please share how this access benefits you.

Research Projects

Organizational Units

Journal Issue

Citation

Velasco, Carlos, Jesus Mateo, Arnoldo Santos, Adriana Mota-Cobian, Fernando Herranz, Juan Pellico, Ruben A. Mota, Samuel España, and Jesus Ruiz-Cabello. 2017. “Assessment of regional pulmonary blood flow using 68Ga-DOTA PET.” EJNMMI Research 7 (1): 7. doi:10.1186/s13550-017-0259-2. http://dx.doi.org/10.1186/s13550-017-0259-2.

Abstract

Background: In vivo determination of regional pulmonary blood flow (PBF) is a valuable tool for the evaluation of many lung diseases. In this study, the use of 68Ga-DOTA PET for the in vivo quantitative determination of regional PBF is proposed. This methodology was implemented and tested in healthy pigs and validated using fluorescent microspheres. The study was performed on young large white pigs (n = 4). To assess the reproducibility and consistency of the method, three PET scans were obtained for each animal. Each radiotracer injection was performed simultaneously to the injection of fluorescent microspheres. PBF images were generated applying a two-compartment exchange model over the dynamic PET images. PET and microspheres values were compared by regression analysis and Bland–Altman plot. Results: The capability of the proposed technique to produce 3D regional PBF images was demonstrated. The correlation evaluation between 68Ga-DOTA PET and microspheres showed a good and significant correlation (r = 0.74, P < 0.001). Conclusions: Assessment of PBF with the proposed technique allows combining the high quantitative accuracy of PET imaging with the use of 68Ga/68Ge generators. Thus, 68Ga-DOTA PET emerges as a potential inexpensive method for measuring PBF in clinical settings with an extended use. Electronic supplementary material The online version of this article (doi:10.1186/s13550-017-0259-2) contains supplementary material, which is available to authorized users.

Description

Research Data

Keywords

PET, Pulmonary blood flow, Gallium-68, Fluorescent microspheres

Terms of Use

This article is made available under the terms and conditions applicable to Other Posted Material (LAA), as set forth at Terms of Service

Endorsement

Review

Supplemented By

Related Stories