Publication:
Validation of A Point-of-Care Lactate Device For Screening At-Risk Adults Receiving Combination Antiretroviral Therapy In Botswana

Thumbnail Image

Date

2011

Published Version

Journal Title

Journal ISSN

Volume Title

Publisher

OMICS Publishing Group
The Harvard community has made this article openly available. Please share how this access benefits you.

Research Projects

Organizational Units

Journal Issue

Citation

Moyo, Sikhulile, Hermann Bussmann, and Phibeon Mangwendeza, P. Dusara, T Gaolathe, M Mine, R Musonda, E. van Widenfelt, V. Novitsky, J. Makhema, RG Marlink, M Essex, CW Wester. 2011. Validation of A Point-of-Care Lactate Device For Screening At-Risk Adults Receiving Combination Antiretroviral Therapy In Botswana. J Antivir Antiretrovir 3, no. 4. doi:10.4172/jaa.1000034.

Research Data

Abstract

BACKGROUND: Nucleoside reverse-transcriptase inhibitors (NRTIs) are a major component of combination antiretroviral therapy (cART) worldwide but they have been associated with mitochondrial toxicities, with one of the most significant being lactic acidosis. In southern Africa, being female and overweight (BMI > 25) as well as receiving d4T and/or ddI-based cART are risk factors for the development of this potentially life-threatening complication. It is challenging in many resource-limited settings to obtain reliable serum lactate measurements while screening for the presence of lactic acidosis. Point-of-care devices, however, are now available that provide simple, accurate measurements of serum lactate levels at relatively low cost. The objective of this study was to assess the agreement of the portable (Accutrend™ handheld) lactate analyzer to the conventional laboratory system for obtaining serum lactate. METHODS: Eighty two "at-risk" cART-treated adults were evaluated, having their lactate levels tested in parallel using both modalities. RESULTS: The mean (range) lactate level for the portable device was 2.28 (0.9-5.0) compared to 1.96 (0.7-5.4) using the conventional method. There was a strong correlation (p<0.05) between the portable device and the conventional means with a Pearson correlation coefficient of 0.92 [95% CI: 0.88-0.95]. The mean bias was 0.33 [95% CI: -0.39-1.04], with the portable device having slightly higher values. CONCLUSION: The use of a portable lactate device provides an accurate and user-friendly means of screening at-risk patients for the presence of lactic acidosis in resource-limited settings with limited laboratory capacity.

Description

Keywords

HIV/AIDS, lactic acidosis, Botswana, point-of-care devices, complications of combination antiretroviral therapy (cART)

Terms of Use

This article is made available under the terms and conditions applicable to Other Posted Material (LAA), as set forth at Terms of Service

Endorsement

Review

Supplemented By

Referenced By

Related Stories