Publication: Flexible Optical Waveguides for Uniform Periscleral Cross-Linking
Open/View Files
Date
2017
Published Version
Journal Title
Journal ISSN
Volume Title
Publisher
The Association for Research in Vision and Ophthalmology
The Harvard community has made this article openly available. Please share how this access benefits you.
Citation
Kwok, Sheldon J. J., Moonseok Kim, Harvey H. Lin, Theo G. Seiler, Eric Beck, Peng Shao, Irene E. Kochevar, Theo Seiler, and Seok-Hyun Yun. 2017. “Flexible Optical Waveguides for Uniform Periscleral Cross-Linking.” Investigative Ophthalmology & Visual Science 58 (5): 2596-2602. doi:10.1167/iovs.17-21559. http://dx.doi.org/10.1167/iovs.17-21559.
Research Data
Abstract
Purpose Scleral cross-linking (SXL) with a photosensitizer and light is a potential strategy to mechanically reinforce the sclera and prevent progressive axial elongation responsible for severe myopia. Current approaches for light delivery to the sclera are cumbersome, do not provide uniform illumination, and only treat a limited area of sclera. To overcome these challenges, we developed flexible optical waveguides optimized for efficient, homogeneous light delivery. Methods: Waveguides were fabricated from polydimethylsiloxane elastomer. Blue light (445 nm) is coupled into the waveguide with an input fiber. Light delivery efficiency from the waveguide to scleral tissue was measured and fit to a theoretical model. SXL was performed on fresh porcine eyes stained with 0.5% riboflavin, using irradiances of 0, 25, and 50 mW/cm2 around the entire equator of the eye. Stiffness of scleral strips was characterized with tensiometry. Results: Light delivery with a waveguide of tapered thickness (1.4–0.5 mm) enhanced the uniformity of light delivery, compared to a flat waveguide, achieving a coefficient of variation of less than 10%. At 8% strain, sclera cross-linked with the waveguides at 50 mW/cm2 for 30 minutes had a Young's modulus of 10.7 ± 1.0 MPa, compared to 5.9 ± 0.5 MPa for no irradiation, with no difference in stiffness between proximally and distally treated halves. The stiffness of waveguide-irradiated samples did not differ from direct irradiation at the same irradiance. Conclusions: We developed flexible waveguides for periscleral cross-linking. We demonstrated efficient and uniform stiffening of a 5-mm-wide equatorial band of scleral tissue.
Description
Other Available Sources
Keywords
photo–cross-linking, optical waveguide, sclera reinforcement, myopia control
Terms of Use
This article is made available under the terms and conditions applicable to Other Posted Material (LAA), as set forth at Terms of Service