Collection of Aerosolized Human Cytokines Using Teflon® Filters

DSpace/Manakin Repository

Collection of Aerosolized Human Cytokines Using Teflon® Filters

Citable link to this page

 

 
Title: Collection of Aerosolized Human Cytokines Using Teflon® Filters
Author: Hwang, Grace M.; McKenzie, Jennifer Helen; McDevitt, James J; Fabian, Maria Patricia; Milton, Donald Kirby

Note: Order does not necessarily reflect citation order of authors.

Citation: McKenzie, Jennifer H., James J. McDevitt, M. Patricia Fabian, Grace M. Hwang, and Donald K. Milton. 2012. Collection of aerosolized human cytokines using teflon® filters. PLoS ONE 7(5): 35814.
Full Text & Related Files:
Abstract: Background: Collection of exhaled breath samples for the analysis of inflammatory biomarkers is an important area of research aimed at improving our ability to diagnose, treat and understand the mechanisms of chronic pulmonary disease. Current collection methods based on condensation of water vapor from exhaled breath yield biomarker levels at or near the detection limits of immunoassays contributing to problems with reproducibility and validity of biomarker measurements. In this study, we compare the collection efficiency of two aerosol-to-liquid sampling devices to a filter-based collection method for recovery of dilute laboratory generated aerosols of human cytokines so as to identify potential alternatives to exhaled breath condensate collection. Methodology/Principal Findings: Two aerosol-to-liquid sampling devices, the SKC® Biosampler and Omni 3000™, as well as Teflon® filters were used to collect aerosols of human cytokines generated using a HEART nebulizer and single-pass aerosol chamber setup in order to compare the collection efficiencies of these sampling methods. Additionally, methods for the use of Teflon® filters to collect and measure cytokines recovered from aerosols were developed and evaluated through use of a high-sensitivity multiplex immunoassay. Our results show successful collection of cytokines from pg/m3 aerosol concentrations using Teflon® filters and measurement of cytokine levels in the sub-picogram/mL concentration range using a multiplex immunoassay with sampling times less than 30 minutes. Significant degradation of cytokines was observed due to storage of cytokines in concentrated filter extract solutions as compared to storage of dry filters. Conclusions: Use of filter collection methods resulted in significantly higher efficiency of collection than the two aerosol-to-liquid samplers evaluated in our study. The results of this study provide the foundation for a potential new technique to evaluate biomarkers of inflammation in exhaled breath samples.
Published Version: doi:10.1371/journal.pone.0035814
Other Sources: http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3344827/pdf/
Terms of Use: This article is made available under the terms and conditions applicable to Other Posted Material, as set forth at http://nrs.harvard.edu/urn-3:HUL.InstRepos:dash.current.terms-of-use#LAA
Citable link to this page: http://nrs.harvard.edu/urn-3:HUL.InstRepos:10433478
Downloads of this work:

Show full Dublin Core record

This item appears in the following Collection(s)

 
 

Search DASH


Advanced Search
 
 

Submitters