Comparison of Spinal Block Levels between Laboring and Nonlaboring Parturients Using Combined Spinal Epidural Technique with Intrathecal Plain Bupivacaine

DSpace/Manakin Repository

Comparison of Spinal Block Levels between Laboring and Nonlaboring Parturients Using Combined Spinal Epidural Technique with Intrathecal Plain Bupivacaine

Citable link to this page

 

 
Title: Comparison of Spinal Block Levels between Laboring and Nonlaboring Parturients Using Combined Spinal Epidural Technique with Intrathecal Plain Bupivacaine
Author: Tang, Yu-Ying; Ren, Xiao-Hui; Lin, Xue-Mei; Zhou, Jie

Note: Order does not necessarily reflect citation order of authors.

Citation: Tang, Yu-Ying, Jie Zhou, Xiao-Hui Ren, and Xue-Mei Lin. 2012. Comparison of spinal block levels between laboring and nonlaboring parturients using combined spinal epidural technique with intrathecal plain bupivacaine. Anesthesiology Research and Practice 2012:187132.
Full Text & Related Files:
Abstract: Background: It was suggested that labor may influence the spread of intrathecal bupivacaine using combined spinal epidural (CSE) technique. However, no previous studies investigated this proposition. We designed this study to investigate the spinal block characteristics of plain bupivacaine between nonlaboring and laboring parturients using CSE technique. Methods: Twenty-five nonlaboring (Group NL) and twenty-five laboring parturients (Group L) undergoing cesarean delivery were enrolled. Following identification of the epidural space at the L3-4 interspace, plain bupivacaine 10 mg was administered intrathecally using CSE technique. The level of sensory block, degree of motor block, and hemodynamic changes were assessed. Results: The baseline systolic blood pressure (SBP) and the maximal decrease of SBP in Group L were significantly higher than those in Group NL (P = 0.002 and P = 0.03, resp.). The median sensory level tested by cold stimulation was T6 for Group NL and T5 for Group L (P = 0.46). The median sensory level tested by pinprick was T7 for both groups (P = 0.35). The degree of motor block was comparable between the two groups (P = 0.85). Conclusion: We did not detect significant differences in the sensory block levels between laboring and nonlaboring parturients using CSE technique with intrathecal plain bupivacaine.
Published Version: doi:10.1155/2012/187132
Other Sources: http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3388316/pdf/
Terms of Use: This article is made available under the terms and conditions applicable to Other Posted Material, as set forth at http://nrs.harvard.edu/urn-3:HUL.InstRepos:dash.current.terms-of-use#LAA
Citable link to this page: http://nrs.harvard.edu/urn-3:HUL.InstRepos:10448841
Downloads of this work:

Show full Dublin Core record

This item appears in the following Collection(s)

 
 

Search DASH


Advanced Search
 
 

Submitters