Preliminary evaluation of a robotic apparatus for the analysis of passive glenohumeral joint kinematics

View/ Open
Author
Rosso, Claudio
Müller, Andreas M
Entezari, Vahid
Dow, William A
McKenzie, Brett
Stanton, Stacey K
Li, Daniel
Cereatti, Andrea
DeAngelis, Joseph P
Croce, Ugo Della
Note: Order does not necessarily reflect citation order of authors.
Published Version
https://doi.org/10.1186/1749-799X-8-24Metadata
Show full item recordCitation
Rosso, C., A. M. Müller, V. Entezari, W. A. Dow, B. McKenzie, S. K. Stanton, D. Li, et al. 2013. “Preliminary evaluation of a robotic apparatus for the analysis of passive glenohumeral joint kinematics.” Journal of Orthopaedic Surgery and Research 8 (1): 24. doi:10.1186/1749-799X-8-24. http://dx.doi.org/10.1186/1749-799X-8-24.Abstract
Background: The shoulder has the greatest range of motion of any joint in the human body. This is due, in part, to the complex interplay between the glenohumeral (GH) joint and the scapulothoracic (ST) articulation. Currently, our ability to study shoulder kinematics is limited, because existing models isolate the GH joint and rely on manual manipulation to create motion, and have low reproducibility. Similarly, most established techniques track shoulder motion discontinuously with limited accuracy. Methods: To overcome these problems, we have designed a novel system in which the shoulder girdle is studied intact, incorporating both GH and ST motions. In this system, highly reproducible trajectories are created using a robotic actuator to control the intact shoulder girdle. High-speed cameras are employed to track retroreflective bone markers continuously. Results: We evaluated this automated system’s capacity to reproducibly capture GH translation in intact and pathologic shoulder conditions. A pair of shoulders (left and right) were tested during forward elevation at baseline, with a winged scapula, and after creation of a full thickness supraspinatus tear. Discussion The system detected differences in GH translations as small as 0.5 mm between different conditions. For each, three consecutive trials were performed and demonstrated high reproducibility and high precision.Other Sources
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3724692/pdf/Terms of Use
This article is made available under the terms and conditions applicable to Other Posted Material, as set forth at http://nrs.harvard.edu/urn-3:HUL.InstRepos:dash.current.terms-of-use#LAACitable link to this page
http://nrs.harvard.edu/urn-3:HUL.InstRepos:11717629
Collections
- HMS Scholarly Articles [17714]
Contact administrator regarding this item (to report mistakes or request changes)