Show simple item record

dc.contributor.authorAkçakaya, Mehmeten_US
dc.contributor.authorNam, Seunghoonen_US
dc.contributor.authorBasha, Tamer A.en_US
dc.contributor.authorKawaji, Keigoen_US
dc.contributor.authorTarokh, Vahiden_US
dc.contributor.authorNezafat, Rezaen_US
dc.date.accessioned2014-10-01T14:27:29Z
dc.date.issued2014en_US
dc.identifier.citationAkçakaya, Mehmet, Seunghoon Nam, Tamer A. Basha, Keigo Kawaji, Vahid Tarokh, and Reza Nezafat. 2014. “An Augmented Lagrangian Based Compressed Sensing Reconstruction for Non-Cartesian Magnetic Resonance Imaging without Gridding and Regridding at Every Iteration.” PLoS ONE 9 (9): e107107. doi:10.1371/journal.pone.0107107. http://dx.doi.org/10.1371/journal.pone.0107107.en
dc.identifier.issn1932-6203en
dc.identifier.urihttp://nrs.harvard.edu/urn-3:HUL.InstRepos:12987224
dc.description.abstractBackground: Non-Cartesian trajectories are used in a variety of fast imaging applications, due to the incoherent image domain artifacts they create when undersampled. While the gridding technique is commonly utilized for reconstruction, the incoherent artifacts may be further removed using compressed sensing (CS). CS reconstruction is typically done using conjugate-gradient (CG) type algorithms, which require gridding and regridding to be performed at every iteration. This leads to a large computational overhead that hinders its applicability. Methods: We sought to develop an alternative method for CS reconstruction that only requires two gridding and one regridding operation in total, irrespective of the number of iterations. This proposed technique is evaluated on phantom images and whole-heart coronary MRI acquired using 3D radial trajectories, and compared to conventional CS reconstruction using CG algorithms in terms of quantitative vessel sharpness, vessel length, computation time, and convergence rate. Results: Both CS reconstructions result in similar vessel length (P = 0.30) and vessel sharpness (P = 0.62). The per-iteration complexity of the proposed technique is approximately 3-fold lower than the conventional CS reconstruction (17.55 vs. 52.48 seconds in C++). Furthermore, for in-vivo datasets, the convergence rate of the proposed technique is faster (60±13 vs. 455±320 iterations) leading to a ∼23-fold reduction in reconstruction time. Conclusions: The proposed reconstruction provides images of similar quality to the conventional CS technique in terms of removing artifacts, but at a much lower computational complexity.en
dc.language.isoen_USen
dc.publisherPublic Library of Scienceen
dc.relation.isversionofdoi:10.1371/journal.pone.0107107en
dc.relation.hasversionhttp://www.ncbi.nlm.nih.gov/pmc/articles/PMC4162575/pdf/en
dash.licenseLAAen_US
dc.subjectMedicine and Health Sciencesen
dc.subjectDiagnostic Medicineen
dc.subjectDiagnostic Radiologyen
dc.subjectMagnetic Resonance Imagingen
dc.subjectRadiology and Imagingen
dc.titleAn Augmented Lagrangian Based Compressed Sensing Reconstruction for Non-Cartesian Magnetic Resonance Imaging without Gridding and Regridding at Every Iterationen
dc.typeJournal Articleen_US
dc.description.versionVersion of Recorden
dc.relation.journalPLoS ONEen
dash.depositing.authorAkçakaya, Mehmeten_US
dc.date.available2014-10-01T14:27:29Z
dc.identifier.doi10.1371/journal.pone.0107107*
dash.contributor.affiliatedNezafat, Reza
dash.contributor.affiliatedAkcakaya, Mehmet
dash.contributor.affiliatedTarokh, Vahid


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record