Evaluation of the modified colorimetric resazurin microtiter plate-based antibacterial assay for rapid and reliable tuberculosis drug susceptibility testing

View/ Open
Published Version
https://doi.org/10.1186/s12866-014-0259-6Metadata
Show full item recordCitation
Katawera, Victoria, Mark Siedner, and Yap Boum II. 2014. “Evaluation of the modified colorimetric resazurin microtiter plate-based antibacterial assay for rapid and reliable tuberculosis drug susceptibility testing.” BMC Microbiology 14 (1): 259. doi:10.1186/s12866-014-0259-6. http://dx.doi.org/10.1186/s12866-014-0259-6.Abstract
Background: The resazurin microtiter assay (classic REMA), a colorimetric liquid culture-based drug susceptibility assay for Mycobacterium tuberculosis (MTB), has been endorsed by the World Health Organization. The assay requires 8-16 days to obtain results, delaying management of drug resistant tuberculosis patients. A modified REMA which allows results in as little as 24 hours for bacterial strains, has been developed and validated using Staphylococcus aureus, but has not yet been evaluated for MTB. Therefore we assessed the performance of the modified REMA for rifampicin (RIF) and isoniazid (INH) susceptibility, using the classic REMA as the reference standard. We also compared simplicity (from the technicians’ point of view), time taken to obtain results (rank-sum testing), specificity and Kappa statistics of the two methods. Results: The modified REMA, which is a one-step procedure, was found to be simpler to perform and results were obtained in a significantly shorter time (5 versus 9 days, p < 0.0001) compared to the classic REMA due to addition of indicator and strain at the same time. The specificity of the modified REMA was low {46.8% (35.5% - 58.4%) for RIF and 13.9% (7.2% - 23.5%) for INH}. Kappa statistics were 16.0% for RIF and 2.0% for INH. Low specificity and kappa statistics are due to indicator reduction by the strains before complete drug activity. Conclusion: Although modified REMA is faster and simpler compared to classic REMA, it is not reliable for MTB drug susceptibility testing.Other Sources
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4192322/pdf/Terms of Use
This article is made available under the terms and conditions applicable to Other Posted Material, as set forth at http://nrs.harvard.edu/urn-3:HUL.InstRepos:dash.current.terms-of-use#LAACitable link to this page
http://nrs.harvard.edu/urn-3:HUL.InstRepos:13347543
Collections
- HMS Scholarly Articles [17878]
Contact administrator regarding this item (to report mistakes or request changes)