Show simple item record

dc.contributor.authorELLINGSON, BENJAMIN M.en_US
dc.contributor.authorKIM, EUNHEEen_US
dc.contributor.authorWOODWORTH, DAVIS C.en_US
dc.contributor.authorMARQUES, HELGAen_US
dc.contributor.authorBOXERMAN, JERROLD L.en_US
dc.contributor.authorSAFRIEL, YAIRen_US
dc.contributor.authorMcKINSTRY, ROBERT C.en_US
dc.contributor.authorBOKSTEIN, FELIXen_US
dc.contributor.authorJAIN, RAJANen_US
dc.contributor.authorCHI, T. LINDAen_US
dc.contributor.authorSORENSEN, A. GREGORYen_US
dc.contributor.authorGILBERT, MARK R.en_US
dc.contributor.authorBARBORIAK, DANIEL P.en_US
dc.date.accessioned2015-05-04T15:28:02Z
dc.date.issued2015en_US
dc.identifier.citationELLINGSON, B. M., E. KIM, D. C. WOODWORTH, H. MARQUES, J. L. BOXERMAN, Y. SAFRIEL, R. C. McKINSTRY, et al. 2015. “Diffusion MRI quality control and functional diffusion map results in ACRIN 6677/RTOG 0625: A multicenter, randomized, phase II trial of bevacizumab and chemotherapy in recurrent glioblastoma.” International Journal of Oncology 46 (5): 1883-1892. doi:10.3892/ijo.2015.2891. http://dx.doi.org/10.3892/ijo.2015.2891.en
dc.identifier.issn1019-6439en
dc.identifier.urihttp://nrs.harvard.edu/urn-3:HUL.InstRepos:15035046
dc.description.abstractFunctional diffusion mapping (fDM) is a cancer imaging technique that quantifies voxelwise changes in apparent diffusion coefficient (ADC). Previous studies have shown value of fDMs in bevacizumab therapy for recurrent glioblastoma multiforme (GBM). The aim of the present study was to implement explicit criteria for diffusion MRI quality control and independently evaluate fDM performance in a multicenter clinical trial (RTOG 0625/ACRIN 6677). A total of 123 patients were enrolled in the current multicenter trial and signed institutional review board-approved informed consent at their respective institutions. MRI was acquired prior to and 8 weeks following therapy. A 5-point QC scoring system was used to evaluate DWI quality. fDM performance was evaluated according to the correlation of these metrics with PFS and OS at the first follow-up time-point. Results showed ADC variability of 7.3% in NAWM and 10.5% in CSF. A total of 68% of patients had usable DWI data and 47% of patients had high quality DWI data when also excluding patients that progressed before the first follow-up. fDM performance was improved by using only the highest quality DWI. High pre-treatment contrast enhancing tumor volume was associated with shorter PFS and OS. A high volume fraction of increasing ADC after therapy was associated with shorter PFS, while a high volume fraction of decreasing ADC was associated with shorter OS. In summary, DWI in multicenter trials are currently of limited value due to image quality. Improvements in consistency of image quality in multicenter trials are necessary for further advancement of DWI biomarkers.en
dc.language.isoen_USen
dc.publisherD.A. Spandidosen
dc.relation.isversionofdoi:10.3892/ijo.2015.2891en
dc.relation.hasversionhttp://www.ncbi.nlm.nih.gov/pmc/articles/PMC4383029/pdf/en
dash.licenseLAAen_US
dc.subjectdiffusion MRIen
dc.subjectfunctional diffusion mapsen
dc.subjectfunctional diffusion mappingen
dc.subjectglioblastomaen
dc.subjectmagnetic resonance imagingen
dc.subjectbevacizumaben
dc.titleDiffusion MRI quality control and functional diffusion map results in ACRIN 6677/RTOG 0625: A multicenter, randomized, phase II trial of bevacizumab and chemotherapy in recurrent glioblastomaen
dc.typeJournal Articleen_US
dc.description.versionVersion of Recorden
dc.relation.journalInternational Journal of Oncologyen
dc.date.available2015-05-04T15:28:02Z
dc.identifier.doi10.3892/ijo.2015.2891*
dash.authorsorderedfalse


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record