Impact of motion correction on reproducibility and spatial variability of quantitative myocardial T2 mapping

DSpace/Manakin Repository

Impact of motion correction on reproducibility and spatial variability of quantitative myocardial T2 mapping

Citable link to this page

 

 
Title: Impact of motion correction on reproducibility and spatial variability of quantitative myocardial T2 mapping
Author: Roujol, Sébastien; Basha, Tamer A.; Weingärtner, Sebastian; Akçakaya, Mehmet; Berg, Sophie; Manning, Warren J.; Nezafat, Reza

Note: Order does not necessarily reflect citation order of authors.

Citation: Roujol, Sébastien, Tamer A. Basha, Sebastian Weingärtner, Mehmet Akçakaya, Sophie Berg, Warren J. Manning, and Reza Nezafat. 2015. “Impact of motion correction on reproducibility and spatial variability of quantitative myocardial T2 mapping.” Journal of Cardiovascular Magnetic Resonance 17 (1): 46. doi:10.1186/s12968-015-0141-1. http://dx.doi.org/10.1186/s12968-015-0141-1.
Full Text & Related Files:
Abstract: Background: To evaluate and quantify the impact of a novel image-based motion correction technique in myocardial T2 mapping in terms of measurement reproducibility and spatial variability. Methods: Twelve healthy adult subjects were imaged using breath-hold (BH), free breathing (FB), and free breathing with respiratory navigator gating (FB + NAV) myocardial T2 mapping sequences. Fifty patients referred for clinical CMR were imaged using the FB + NAV sequence. All sequences used a T2 prepared (T2prep) steady-state free precession acquisition. In-plane myocardial motion was corrected using an adaptive registration of varying contrast-weighted images for improved tissue characterization (ARCTIC). DICE similarity coefficient (DSC) and myocardial boundary errors (MBE) were measured to quantify the motion estimation accuracy in healthy subjects. T2 mapping reproducibility and spatial variability were evaluated in healthy subjects using 5 repetitions of the FB + NAV sequence with either 4 or 20 T2prep echo times (TE). Subjective T2 map quality was assessed in patients by an experienced reader using a 4-point scale (1-non diagnostic, 4-excellent). Results: ARCTIC led to increased DSC in BH data (0.85 ± 0.08 vs. 0.90 ± 0.02, p = 0.007), FB data (0.78 ± 0.13 vs. 0.90 ± 0.21, p < 0.001), and FB + NAV data (0.86 ± 0.05 vs. 0.90 ± 0.02, p = 0.002), and reduced MBE in BH data (0.90 ± 0.40 vs. 0.64 ± 0.19 mm, p = 0.005), FB data (1.21 ± 0.65 vs. 0.63 ± 0.10 mm, p < 0.001), and FB + NAV data (0.81 ± 0.21 vs. 0.63 ± 0.08 mm, p < 0.001). Improved reproducibility (4TE: 5.3 ± 2.5 ms vs. 4.0 ± 1.5 ms, p = 0.016; 20TE: 3.9 ± 2.3 ms vs. 2.2 ± 0.5 ms, p = 0.002), reduced spatial variability (4TE: 12.8 ± 3.5 ms vs. 10.3 ± 2.5 ms, p < 0.001; 20TE: 9.7 ± 3.5 ms vs. 7.5 ± 1.4 ms) and improved subjective score of T2 map quality (3.43 ± 0.79 vs. 3.69 ± 0.55, p < 0.001) were obtained using ARCTIC. Conclusions: The ARCTIC technique substantially reduces spatial mis-alignment among T2-weighted images and improves the reproducibility and spatial variability of in-vivo T2 mapping.
Published Version: doi:10.1186/s12968-015-0141-1
Other Sources: http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4465156/pdf/
Terms of Use: This article is made available under the terms and conditions applicable to Other Posted Material, as set forth at http://nrs.harvard.edu/urn-3:HUL.InstRepos:dash.current.terms-of-use#LAA
Citable link to this page: http://nrs.harvard.edu/urn-3:HUL.InstRepos:17295773
Downloads of this work:

Show full Dublin Core record

This item appears in the following Collection(s)

 
 

Search DASH


Advanced Search
 
 

Submitters