Show simple item record

dc.contributor.authorRiahi, Rezaen_US
dc.contributor.authorShaegh, Seyed Ali Mousavien_US
dc.contributor.authorGhaderi, Masoumehen_US
dc.contributor.authorZhang, Yu Shrikeen_US
dc.contributor.authorShin, Su Ryonen_US
dc.contributor.authorAleman, Julioen_US
dc.contributor.authorMassa, Solangeen_US
dc.contributor.authorKim, Duckjinen_US
dc.contributor.authorDokmeci, Mehmet Remzien_US
dc.contributor.authorKhademhosseini, Alien_US
dc.date.accessioned2016-05-02T16:59:42Z
dc.date.issued2016en_US
dc.identifier.citationRiahi, Reza, Seyed Ali Mousavi Shaegh, Masoumeh Ghaderi, Yu Shrike Zhang, Su Ryon Shin, Julio Aleman, Solange Massa, Duckjin Kim, Mehmet Remzi Dokmeci, and Ali Khademhosseini. 2016. “Automated microfluidic platform of bead-based electrochemical immunosensor integrated with bioreactor for continual monitoring of cell secreted biomarkers.” Scientific Reports 6 (1): 24598. doi:10.1038/srep24598. http://dx.doi.org/10.1038/srep24598.en
dc.identifier.issn2045-2322en
dc.identifier.urihttp://nrs.harvard.edu/urn-3:HUL.InstRepos:26860051
dc.description.abstractThere is an increasing interest in developing microfluidic bioreactors and organs-on-a-chip platforms combined with sensing capabilities for continual monitoring of cell-secreted biomarkers. Conventional approaches such as ELISA and mass spectroscopy cannot satisfy the needs of continual monitoring as they are labor-intensive and not easily integrable with low-volume bioreactors. This paper reports on the development of an automated microfluidic bead-based electrochemical immunosensor for in-line measurement of cell-secreted biomarkers. For the operation of the multi-use immunosensor, disposable magnetic microbeads were used to immobilize biomarker-recognition molecules. Microvalves were further integrated in the microfluidic immunosensor chip to achieve programmable operations of the immunoassay including bead loading and unloading, binding, washing, and electrochemical sensing. The platform allowed convenient integration of the immunosensor with liver-on-chips to carry out continual quantification of biomarkers secreted from hepatocytes. Transferrin and albumin productions were monitored during a 5-day hepatotoxicity assessment in which human primary hepatocytes cultured in the bioreactor were treated with acetaminophen. Taken together, our unique microfluidic immunosensor provides a new platform for in-line detection of biomarkers in low volumes and long-term in vitro assessments of cellular functions in microfluidic bioreactors and organs-on-chips.en
dc.language.isoen_USen
dc.publisherNature Publishing Groupen
dc.relation.isversionofdoi:10.1038/srep24598en
dc.relation.hasversionhttp://www.ncbi.nlm.nih.gov/pmc/articles/PMC4838915/pdf/en
dash.licenseLAAen_US
dc.titleAutomated microfluidic platform of bead-based electrochemical immunosensor integrated with bioreactor for continual monitoring of cell secreted biomarkersen
dc.typeJournal Articleen_US
dc.description.versionVersion of Recorden
dc.relation.journalScientific Reportsen
dash.depositing.authorDokmeci, Mehmet Remzien_US
dc.date.available2016-05-02T16:59:42Z
dc.identifier.doi10.1038/srep24598*
dash.contributor.affiliatedKhademhosseini, Ali
dash.contributor.affiliatedDokmeci, Mehmet R.


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record