A biologically-inspired multi-joint soft exosuit that can reduce the energy cost of loaded walking

DSpace/Manakin Repository

A biologically-inspired multi-joint soft exosuit that can reduce the energy cost of loaded walking

Citable link to this page

 

 
Title: A biologically-inspired multi-joint soft exosuit that can reduce the energy cost of loaded walking
Author: Panizzolo, Fausto; Galiana, Ignacio; Asbeck, Alan; Siviy, Christopher James; Schmidt, Kai; Walsh, Conor J

Note: Order does not necessarily reflect citation order of authors.

Citation: Panizzolo, Fausto A., Ignacio Galiana, Alan T. Asbeck, Christopher Siviy, Kai Schmidt, Kenneth G. Holt, and Conor J. Walsh. 2016. “A Biologically-Inspired Multi-Joint Soft Exosuit That Can Reduce the Energy Cost of Loaded Walking.” J NeuroEngineering Rehabil 13 (1) (May 12). doi:10.1186/s12984-016-0150-9.
Full Text & Related Files:
Abstract: Background: Carrying load alters normal walking, imposes additional stress to the musculoskeletal system, and results in an increase in energy consumption and a consequent earlier onset of fatigue. This phenomenon is largely due to increased work requirements in lower extremity joints, in turn requiring higher muscle activation. The aim of this work was to assess the biomechanical and physiological effects of a multi-joint soft exosuit that applies assistive torques to the biological hip and ankle joints during loaded walking. Methods: The exosuit was evaluated under three conditions: powered (EXO_ON), unpowered (EXO_OFF) and unpowered removing the equivalent mass of the device (EXO_OFF_EMR). Seven participants walked on an instrumented split-belt treadmill and carried a load equivalent to 30% their body mass. We assessed their metabolic cost of walking, kinetics, kinematics, and lower limb muscle activation using a portable gas analysis system, motion capture system, and surface electromyography. Results: Our results showed that the exosuit could deliver controlled forces to a wearer. Net metabolic power in the EXO_ON condition (7.5±0.6 W kg-1) was 7.3±5.0% and 14.2±6.1% lower than in the EXO_OFF_EMR condition (7.9 ±0.8 W kg-1; p = 0.027) and in the EXO_OFF condition (8.5±0.9W kg-1; p = 0.005), respectively. The exosuit also reduced the total joint positive biological work (sum of hip, knee and ankle) when comparing the EXO_ON condition (1.06±0.16 J kg-1) with respect to the EXO_OFF condition (1.28±0.26 J kg-1; p = 0.020) and to the EXO_OFF_EMR condition (1.22±0.21 J kg-1; p = 0.007). Conclusions: The results of the present work demonstrate for the first time that a soft wearable robot can improve walking economy. These findings pave the way for future assistive devices that may enhance or restore gait in other applications.
Published Version: 10.1186/s12984-016-0150-9
Terms of Use: This article is made available under the terms and conditions applicable to Other Posted Material, as set forth at http://nrs.harvard.edu/urn-3:HUL.InstRepos:dash.current.terms-of-use#LAA
Citable link to this page: http://nrs.harvard.edu/urn-3:HUL.InstRepos:27768973
Downloads of this work:

Show full Dublin Core record

This item appears in the following Collection(s)

 
 

Search DASH


Advanced Search
 
 

Submitters