Left and right ventricular dyssynchrony and strains from cardiovascular magnetic resonance feature tracking do not predict deterioration of ventricular function in patients with repaired tetralogy of Fallot

DSpace/Manakin Repository

Left and right ventricular dyssynchrony and strains from cardiovascular magnetic resonance feature tracking do not predict deterioration of ventricular function in patients with repaired tetralogy of Fallot

Citable link to this page

 

 
Title: Left and right ventricular dyssynchrony and strains from cardiovascular magnetic resonance feature tracking do not predict deterioration of ventricular function in patients with repaired tetralogy of Fallot
Author: Jing, Linyuan; Wehner, Gregory J.; Suever, Jonathan D.; Charnigo, Richard J.; Alhadad, Sudad; Stearns, Evan; Mojsejenko, Dimitri; Haggerty, Christopher M.; Hickey, Kelsey; Valente, Anne Marie; Geva, Tal; Powell, Andrew J.; Fornwalt, Brandon K.

Note: Order does not necessarily reflect citation order of authors.

Citation: Jing, L., G. J. Wehner, J. D. Suever, R. J. Charnigo, S. Alhadad, E. Stearns, D. Mojsejenko, et al. 2016. “Left and right ventricular dyssynchrony and strains from cardiovascular magnetic resonance feature tracking do not predict deterioration of ventricular function in patients with repaired tetralogy of Fallot.” Journal of Cardiovascular Magnetic Resonance 18 (1): 49. doi:10.1186/s12968-016-0268-8. http://dx.doi.org/10.1186/s12968-016-0268-8.
Full Text & Related Files:
Abstract: Background: Patients with repaired tetralogy of Fallot (rTOF) suffer from progressive ventricular dysfunction decades after their surgical repair. We hypothesized that measures of ventricular strain and dyssynchrony would predict deterioration of ventricular function in patients with rTOF. Methods: A database search identified all patients at a single institution with rTOF who underwent cardiovascular magnetic resonance (CMR) at least twice, >6 months apart, without intervening surgical or catheter procedures. Seven primary predictors were derived from the first CMR using a custom feature tracking algorithm: left (LV), right (RV) and inter-ventricular dyssynchrony, LV and RV peak global circumferential strains, and LV and RV peak global longitudinal strains. Three outcomes were defined, whose changes were assessed over time: RV end-diastolic volume, and RV and LV ejection fraction. Multivariate linear mixed models were fit to investigate relationships of outcomes to predictors and ten potential baseline confounders. Results: One hundred fifty-three patients with rTOF (23 ± 14 years, 50 % male) were included. The mean follow-up duration between the first and last CMR was 2.9 ± 1.3 years. After adjustment for confounders, none of the 7 primary predictors were significantly associated with change over time in the 3 outcome variables. Only 1–17 % of the variability in the change over time in the outcome variables was explained by the baseline predictors and potential confounders. Conclusions: In patients with repaired tetralogy of Fallot, ventricular dyssynchrony and global strain derived from cine CMR were not significantly related to changes in ventricular size and function over time. The ability to predict deterioration in ventricular function in patients with rTOF using current methods is limited. Electronic supplementary material The online version of this article (doi:10.1186/s12968-016-0268-8) contains supplementary material, which is available to authorized users.
Published Version: doi:10.1186/s12968-016-0268-8
Other Sources: http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4993000/pdf/
Terms of Use: This article is made available under the terms and conditions applicable to Other Posted Material, as set forth at http://nrs.harvard.edu/urn-3:HUL.InstRepos:dash.current.terms-of-use#LAA
Citable link to this page: http://nrs.harvard.edu/urn-3:HUL.InstRepos:29002402