Show simple item record

dc.contributor.authorLowry, Eugene A.en_US
dc.contributor.authorHou, Jingen_US
dc.contributor.authorHennein, Laurenen_US
dc.contributor.authorChang, Robert T.en_US
dc.contributor.authorLin, Shanen_US
dc.contributor.authorKeenan, Jeremyen_US
dc.contributor.authorWang, Sean K.en_US
dc.contributor.authorIanchulev, Seanen_US
dc.contributor.authorPasquale, Louis R.en_US
dc.contributor.authorHan, Yingen_US
dc.date.accessioned2016-10-11T20:26:16Z
dc.date.issued2016en_US
dc.identifier.citationLowry, Eugene A., Jing Hou, Lauren Hennein, Robert T. Chang, Shan Lin, Jeremy Keenan, Sean K. Wang, Sean Ianchulev, Louis R. Pasquale, and Ying Han. 2016. “Comparison of Peristat Online Perimetry with the Humphrey Perimetry in a Clinic-Based Setting.” Translational Vision Science & Technology 5 (4): 4. doi:10.1167/tvst.5.4.4. http://dx.doi.org/10.1167/tvst.5.4.4.en
dc.identifier.issn2164-2591en
dc.identifier.urihttp://nrs.harvard.edu/urn-3:HUL.InstRepos:29002465
dc.description.abstractPurpose We determined the receiver operating characteristic (ROC) curves for Peristat online perimetry at detecting varying degrees of glaucoma and the correlation between Peristat online perimetry and Humphrey visual field. Methods: A prospective, comparative study of Peristat online perimetry (an achromatic static computer threshold testing program) and Humphrey visual field (HVF) 24-2 SITA standard testing was performed by 63 glaucoma patients and 30 healthy controls in random order. The number of total adjacent abnormal test points were identified for each test, and compared with Spearman correlation. Receive operating characteristic curves were generated for Peristat online perimetry detection of mild and moderate-severe glaucoma patients using contrast sensitivity thresholds of −16.7, −21.7, and −26.7 dB. Results: The area under the ROC curve for glaucoma detection ranged from 0.77 to 0.81 for mild disease (mean deviation [MD], >−6 dB on HVF) and 0.85 to 0.87 for moderate to severe disease (MD, <−6 dB on HVF) depending on contrast threshold. Peristat online perimetry and Humphrey visual field abnormal points were highly correlated with Spearman rank correlations ranging from 0.55 to 0.77 (all P < 0.001). Conclusions: Peristat online perimetry exhibits a reasonable ROC curve without specialized equipment and exhibited significant correlation with the conventional 24° Humphrey visual field test. Translational Relevance Low cost widely available internet-based visual fields may complement traditional office-based visual field testing.en
dc.language.isoen_USen
dc.publisherThe Association for Research in Vision and Ophthalmologyen
dc.relation.isversionofdoi:10.1167/tvst.5.4.4en
dc.relation.hasversionhttp://www.ncbi.nlm.nih.gov/pmc/articles/PMC4959820/pdf/en
dash.licenseLAAen_US
dc.subjectperimetryen
dc.subjectglaucomaen
dc.subjectonlineen
dc.subjectvisual fielden
dc.titleComparison of Peristat Online Perimetry with the Humphrey Perimetry in a Clinic-Based Settingen
dc.typeJournal Articleen_US
dc.description.versionVersion of Recorden
dc.relation.journalTranslational Vision Science & Technologyen
dash.depositing.authorPasquale, Louis R.en_US
dc.date.available2016-10-11T20:26:16Z
dc.identifier.doi10.1167/tvst.5.4.4*
dash.contributor.affiliatedPasquale, Louis


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record