Assessment of whole blood thrombosis in a microfluidic device lined by fixed human endothelium
View/ Open
Author
Jain, Abhishek
van der Meer, Andries D.
Barrile, Riccardo
Lai, Angela
Otieno, Monicah A.
Louden, Calvert S.
Hamilton, Geraldine A.
Note: Order does not necessarily reflect citation order of authors.
Published Version
https://doi.org/10.1007/s10544-016-0095-6Metadata
Show full item recordCitation
Jain, A., A. D. van der Meer, A. Papa, R. Barrile, A. Lai, B. L. Schlechter, M. A. Otieno, et al. 2016. “Assessment of whole blood thrombosis in a microfluidic device lined by fixed human endothelium.” Biomedical Microdevices 18 (1): 73. doi:10.1007/s10544-016-0095-6. http://dx.doi.org/10.1007/s10544-016-0095-6.Abstract
The vascular endothelium and shear stress are critical determinants of physiological hemostasis and platelet function in vivo, yet current diagnostic and monitoring devices do not fully incorporate endothelial function under flow in their assessment and, therefore, they can be unreliable and inaccurate. It is challenging to include the endothelium in assays for clinical laboratories or point-of-care settings because living cell cultures are not sufficiently robust. Here, we describe a microfluidic device that is lined by a human endothelium that is chemically fixed, but still retains its ability to modulate hemostasis under continuous flow in vitro even after few days of storage. This device lined with a fixed endothelium supports formation of platelet-rich thrombi in the presence of physiological shear, similar to a living arterial vessel. We demonstrate the potential clinical value of this device by showing that thrombus formation and platelet function can be measured within minutes using a small volume (0.5 mL) of whole blood taken from subjects receiving antiplatelet medications. The inclusion of a fixed endothelial microvessel will lead to biomimetic analytical devices that can potentially be used for diagnostics and point-of-care applications. Electronic supplementary material The online version of this article (doi:10.1007/s10544-016-0095-6) contains supplementary material, which is available to authorized users.Other Sources
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4963439/pdf/Terms of Use
This article is made available under the terms and conditions applicable to Other Posted Material, as set forth at http://nrs.harvard.edu/urn-3:HUL.InstRepos:dash.current.terms-of-use#LAACitable link to this page
http://nrs.harvard.edu/urn-3:HUL.InstRepos:29002611
Collections
- FAS Scholarly Articles [18292]
- HMS Scholarly Articles [17922]
Contact administrator regarding this item (to report mistakes or request changes)