dc.identifierQuick submit: 2017-03-22T15:54:50-0400
dc.identifier.citationSharp, Gregory C., Hsiao Ming Lu, Alexei Trofimov, Xiaoli Tang, Steve B. Jiang, Julie Turcotte, David P. Gierga, George T. Y. Chen, and Theodore S. Hong. 2007. “Assessing Residual Motion for Gated Proton-Beam Radiotherapy.” Journal of Radiation Research 48 (Suppl.A): A55–A59. doi:10.1269/jrr.48.a55.en_US
dc.identifier.issn0449-3060en_US
dc.identifier.urihttp://nrs.harvard.edu/urn-3:HUL.InstRepos:32431060
dc.description.abstractGated radiation therapy is a promising method for improving the dose conformality of treatments to moving targets and reducing the total volume of irradiated tissue. Target motion is of particular concern in proton beam radiotherapy, due to the finite range of proton dose deposition in tissue. Gating allows one to reduce the extent of variation, due to respiration, of the radiological depth to target during treatment delivery. However, respiratory surrogates typically used for gating do not always accurately reflect the position of the internal target. For instance, a phase delay often exists between the internal motion and the motion of the surrogate. Another phenomenon, baseline drifting refers to a gradual change in the exhale position over time, which generally affects the external and internal markers differently. This study examines the influence of these two physiological phenomena on gated radiotherapy using an external surrogate.en_US
dc.language.isoen_USen_US
dc.publisherOxford University Press (OUP)en_US
dc.relation.isversionof10.1269/jrr.48.a55en_US
dash.licenseLAA
dc.titleAssessing Residual Motion for Gated Proton-Beam Radiotherapyen_US
dc.typeJournal Articleen_US
dc.date.updated2017-03-22T19:54:51Z
dc.description.versionVersion of Recorden_US
dc.relation.journalJournal of Radiation Researchen_US
dash.depositing.authorLu, Hsiao-ming
dc.date.available2007
dc.date.available2017-04-25T19:55:41Z
dc.identifier.doi10.1269/jrr.48.a55*
dash.contributor.affiliatedGierga, David
dash.contributor.affiliatedChen, George
dash.contributor.affiliatedTrofimov, Alexei
dash.contributor.affiliatedLu, Hsiao-Ming
dash.contributor.affiliatedHong, Theodore
dash.contributor.affiliatedSharp, Gregory


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record