Development of in situ sulfur four-isotope analysis with multiple Faraday cup detectors by SIMS and application to pyrite grains in a Paleoproterozoic glaciogenic sandstone

DSpace/Manakin Repository

Development of in situ sulfur four-isotope analysis with multiple Faraday cup detectors by SIMS and application to pyrite grains in a Paleoproterozoic glaciogenic sandstone

Citable link to this page

 

 
Title: Development of in situ sulfur four-isotope analysis with multiple Faraday cup detectors by SIMS and application to pyrite grains in a Paleoproterozoic glaciogenic sandstone
Author: Ushikubo, Takayuki; Williford, Kenneth H.; Farquhar, James; Johnston, David T; Van Kranendonk, Martin J.; Valley, John W.

Note: Order does not necessarily reflect citation order of authors.

Citation: Ushikubo, Takayuki, Kenneth H. Williford, James Farquhar, David T. Johnston, Martin J. Van Kranendonk, and John W. Valley. 2014. “Development of in Situ Sulfur Four-Isotope Analysis with Multiple Faraday Cup Detectors by SIMS and Application to Pyrite Grains in a Paleoproterozoic Glaciogenic Sandstone.” Chemical Geology 383 (September): 86–99. doi:10.1016/j.chemgeo.2014.06.006.
Access Status: Full text of the requested work is not available in DASH at this time (“dark deposit”). For more information on dark deposits, see our FAQ.
Full Text & Related Files:
Abstract: An in situ sulfur four-isotope analysis technique with multiple Faraday cup detectors by ion microprobe was developed and applied to detrital pyrite grains in ~2.4 Ga glaciogenic sandstone from the Meteorite Bore Member of the Turee Creek Group, Western Australia. Data are standardized with the UWPy-1 pyrite standard (δ34S =16.04 ± 0.18‰, Δ33S = −0.003 ± 0.009‰, and Δ36S = −0.21 ± 0.24‰, 2 SD) whose sulfur four isotopes were newly determined by gas-source mass spectrometry. Typical reproducibility at two standard deviations (2 SD) of spot-to-spot analyses of standard UWPy-1 pyrite with a primary beam size of ~20 μm were ±0.23, ±0.05, and ±0.86‰ for δ34S, Δ33S, and Δ36S, respectively. The measured 36S/32S ratio [1 / (6641 ± 27)] is approximately 19‰ lower than the published ratio for VCDT, and we propose a revision of the 36S abundance in VCDT. Pyrite grains in ~2.4 Ga glaciogenic sandstone have wide ranging sulfur isotope ratios (−32.7 to 13.5 for δ34S, −3.03 to 11.66 for Δ33S, and−9.7 to 4.6 for Δ36S, respectively). Somepyrite grains are zoned in δ34S valueswithin a grain. Sulfur isotope ratios of most pyrite grains are distributed along a line with slope = −0.9 for Δ33S vs. Δ36S, suggesting that pyrite grains mostly derived from a limited range of source rocks and near-surface sulfur reservoirs. One pyrite aggregate has a distinct texture fromother pyrite grains in the same sandstone, and yields a significant mass-independent deficit in 36S with a small excess in 33S (Δ36S/Δ33S ~−4‰). This is used to suggest that this grain authigenically formed by biological activity during or after sedimentation. Thiswork demonstrates that the use of multiple Faraday cup detectors provides improved accuracy and precision for in situ sulfur fourisotope analysis with secondary ion mass spectrometry
Published Version: doi:10.1016/j.chemgeo.2014.06.006
Citable link to this page: http://nrs.harvard.edu/urn-3:HUL.InstRepos:33370042