Effect of Bar-Code Technology on the Safety of Medication Administration
Author
Poon, Eric G.
Keohane, Carol A.
Yoon, Catherine S.
Ditmore, Matthew
Bane, Anne
Levtzion-Korach, Osnat
Moniz, Thomas
Rothschild, Jeffrey M.
Kachalia, Allen B.
Hayes, Judy
Churchill, William W.
Whittemore, Anthony D.
Gandhi, Tejal K.
Published Version
https://doi.org/10.1056/NEJMsa0907115Metadata
Show full item recordCitation
Simon, Steven, J. Stewart Evans, Alison Benjamin, David Delano, and David Bates. 2009. "Patients’ attitudes toward electronic health information exchange: qualitative study." Journal of medical Internet research 11, no. 3: e30.Abstract
BACKGROUNDSerious medication errors are common in hospitals and often occur during order transcription or administration of medication. To help prevent such errors, technol- ogy has been developed to verify medications by incorporating bar-code verification technology within an electronic medication-administration system (bar-code eMAR).
METHODS
We conducted a before-and-after, quasi-experimental study in an academic medical center that was implementing the bar-code eMAR. We assessed rates of errors in order transcription and medication administration on units before and after imple- mentation of the bar-code eMAR. Errors that involved early or late administration of medications were classified as timing errors and all others as nontiming errors. Two clinicians reviewed the errors to determine their potential to harm patients and classified those that could be harmful as potential adverse drug events.
RESULTS
We observed 14,041 medication administrations and reviewed 3082 order transcrip- tions. Observers noted 776 nontiming errors in medication administration on units that did not use the bar-code eMAR (an 11.5% error rate) versus 495 such errors on units that did use it (a 6.8% error rate) — a 41.4% relative reduction in errors (P<0.001). The rate of potential adverse drug events (other than those associated with timing errors) fell from 3.1% without the use of the bar-code eMAR to 1.6% with its use, representing a 50.8% relative reduction (P<0.001). The rate of timing errors in medication administration fell by 27.3% (P<0.001), but the rate of poten- tial adverse drug events associated with timing errors did not change significantly. Transcription errors occurred at a rate of 6.1% on units that did not use the bar- code eMAR but were completely eliminated on units that did use it.
CONCLUSIONS
Use of the bar-code eMAR substantially reduced the rate of errors in order tran- scription and in medication administration as well as potential adverse drug events, although it did not eliminate such errors. Our data show that the bar-code eMAR is an important intervention to improve medication safety. (ClinicalTrials.gov number, NCT00243373.)
Terms of Use
This article is made available under the terms and conditions applicable to Other Posted Material, as set forth at http://nrs.harvard.edu/urn-3:HUL.InstRepos:dash.current.terms-of-use#LAACitable link to this page
https://nrs.harvard.edu/URN-3:HUL.INSTREPOS:37367285
Collections
- HMS Scholarly Articles [17843]
Contact administrator regarding this item (to report mistakes or request changes)