dc.identifier.urihttps://nrs.harvard.edu/URN-3:HUL.INSTREPOS:37369351*
dc.description.abstractChemical exchange–dependent saturation transfer and paramagnetic chemical exchange–dependent saturation transfer are agent-mediated contrast mechanisms that depend on saturating spins at the resonant frequency of the exchangeable protons on the agent, thereby indirectly saturating the bulk water. In general, longer saturating pulses produce stronger chemical and paramagnetic exchange–dependent saturation transfer effects, with returns diminishing for pulses longer than T1. This could make imaging slow, so one approach to chemical exchange–dependent saturation transfer imaging has been to follow a long, frequency-selective saturation period by a fast imaging method. A new approach is to insert a short frequency-selective saturation pulse before each spatially selective observation pulse in a standard, two-dimensional, gradient-echo pulse sequence. Being much less than T1 apart, the saturation pulses have a cumulative effect. Interleaved, multislice imaging is straightforward. Observation pulses directed at one slice did not produce observable, unintended chemical exchange–dependent saturation transfer effects in another slice. Pulse repetition time and signal-to noise ratio increase in the normal way as more slices are imaged simultaneously.en_US
dc.language.isoen_USen_US
dc.publisherWileyen_US
dc.relation.isversionofdoi:10.1002/mrm.22193en_US
dc.relation.hasversionhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC2925508/en_US
dash.licenseLAA
dc.subjectRadiology Nuclear Medicine and imagingen_US
dc.titleA multislice gradient echo pulse sequence for CEST imagingen_US
dc.title.alternativeMultislice Gradient Echo CEST Imaging
dc.typeJournal Articleen_US
dc.description.versionAccepted Manuscripten_US
dc.relation.journalMagnetic Resonance in Medicineen_US
dash.depositing.authorAlsop, David
dc.date.available2021-09-09T15:52:03Z
dc.identifier.doi10.1002/mrm.22193
dc.source.journalMagn. Reson. Med.
dash.source.volume63en_US
dash.source.page253-256en_US
dash.source.issue1en_US
dash.contributor.affiliatedLenkinski, Robert
dash.contributor.affiliatedAlsop, David


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record