dc.identifier.citationKang, DongKyun, Hongki Yoo, Priyanka Jillella, Brett E. Bouma, and Guillermo J. Tearney. 2011. Comprehensive volumetric confocal microscopy with adaptive focusing. Biomedical Optics Express 2(6): 1412-1422.en_US
dc.identifier.issn2156-7085en_US
dc.identifier.urihttp://nrs.harvard.edu/urn-3:HUL.InstRepos:8462360
dc.description.abstractComprehensive microscopy of distal esophagus could greatly improve the screening and surveillance of esophageal diseases such as Barrett’s esophagus by providing histomorphologic information over the entire region at risk. Spectrally encoded confocal microscopy (SECM) is a high-speed reflectance confocal microscopy technology that can be configured to image the entire distal esophagus by helically scanning the beam using optics within a balloon-centering probe. It is challenging to image the human esophagus in vivo with balloon-based SECM, however, because patient motion and anatomic tissue surface irregularities decenter the optics, making it difficult to keep the focus at a predetermined location within the tissue as the beam is scanned. In this paper, we present a SECM probe equipped with an adaptive focusing mechanism that can compensate for tissue surface irregularity and dynamic focal variation. A tilted arrangement of the objective lens is employed in the SECM probe to provide feedback signals to an adaptive focusing mechanism. The tilted configuration also allows the probe to obtain reflectance confocal data from multiple depth levels, enabling the acquisition of three-dimensional volumetric data during a single scan of the probe. A tissue phantom with a surface area of \(12.6 cm^2\) was imaged using the new SECM probe, and 8 large-area reflectance confocal microscopy images were acquired over the depth range of \(56 \mu m\) in 20 minutes. Large-area SECM images of excised swine small intestine tissue were also acquired, enabling the visualization of villous architecture, epithelium, and lamina propria. The adaptive focusing mechanism was demonstrated to enable acquisition of in-focus images even when the probe was not centered and the tissue surface was irregular.en_US
dc.language.isoen_USen_US
dc.publisherOptical Society of Americaen_US
dc.relation.isversionofdoi:10.1364/BOE.2.001412en_US
dc.relation.hasversionhttp://www.ncbi.nlm.nih.gov/pmc/articles/PMC3114210/pdf/en_US
dash.licenseLAA
dc.subjectmedical optics and biotechnologyen_US
dc.subjectconfocal microscopyen_US
dc.subjectendoscopic imagingen_US
dc.subjectgastrointestinalen_US
dc.titleComprehensive Volumetric Confocal Microscopy with Adaptive Focusingen_US
dc.typeJournal Articleen_US
dc.description.versionVersion of Recorden_US
dc.relation.journalBiomedical Optics Expressen_US
dash.depositing.authorTearney, Guillermo James
dc.date.available2012-03-29T18:14:56Z
dash.affiliation.other100152en_US
dash.affiliation.other100152en_US
dash.affiliation.other100143en_US
dash.affiliation.other100152en_US
dash.affiliation.other103563en_US
dc.identifier.doi10.1364/BOE.2.001412*
dash.contributor.affiliatedKang, Dongkyun
dash.contributor.affiliatedYoo, Hongki
dash.contributor.affiliatedTearney, Guillermo
dash.contributor.affiliatedBouma, Brett


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record