dc.contributor.author | Meriles, Carlos A. | |
dc.contributor.author | Jiang, Liang | |
dc.contributor.author | Goldstein, Garry | |
dc.contributor.author | Hodges, Jonathan S. | |
dc.contributor.author | Maze, Jeronimo | |
dc.contributor.author | Lukin, Mikhail D. | |
dc.contributor.author | Cappellaro, Paola | |
dc.date.accessioned | 2012-07-03T14:01:03Z | |
dc.date.issued | 2010 | |
dc.identifier.citation | Carlos A. Meriles, Liang Jiang, Garry Goldstein, Jonathan S. Hodges, Jeronimo Maze, Mikhail D. Lukin and Paola Cappellaro. 2010. Imaging mesoscopic nuclear spin noise with a diamond magnetometer. Journal of Chemical Physics 133(12): 124105. | en_US |
dc.identifier.issn | 0021-9606 | en_US |
dc.identifier.issn | 1089-7690 | en_US |
dc.identifier.uri | http://nrs.harvard.edu/urn-3:HUL.InstRepos:8951175 | |
dc.description.abstract | Magnetic resonance imaging can characterize and discriminate among tissues using their diverse physical and biochemical properties. Unfortunately, submicrometer screening of biological specimens is presently not possible, mainly due to lack of detection sensitivity. Here we analyze the use of a nitrogen-vacancy center in diamond as a magnetic sensor for nanoscale nuclear spin imaging and spectroscopy. We examine the ability of such a sensor to probe the fluctuations of the “classical” dipolar field due to a large number of neighboring nuclear spins in a densely protonated sample. We identify detection protocols that appropriately take into account the quantum character of the sensor and find a signal-to-noise ratio compatible with realistic experimental parameters. Through various example calculations we illustrate different kinds of image contrast. In particular, we show how to exploit the comparatively long nuclear spin correlation times to reconstruct a local, high-resolution sample spectrum. | en_US |
dc.description.sponsorship | Physics | en_US |
dc.language.iso | en_US | en_US |
dc.publisher | American Institute of Physics | en_US |
dc.relation.isversionof | doi:10.1063/1.3483676 | en_US |
dc.relation.hasversion | http://www.its.caltech.edu/~ljiang/academic/papers/Imaging%20mesoscopic%20nuclear%20spin%20noise%20with%20a%20diamond%20magnetometer%20--%20Meriles%20Jiang%20Goldstein%20Hodges%20Maze%20Lukin%20Cappellaro%20--%20JCP%202010.pdf | en_US |
dash.license | LAA | |
dc.subject | association | en_US |
dc.subject | biochemistry | en_US |
dc.subject | biological NMR | en_US |
dc.subject | biological techniques | en_US |
dc.subject | biological tissues | en_US |
dc.subject | diamond | en_US |
dc.subject | magnetic sensors | en_US |
dc.subject | nanobiotechnology | en_US |
dc.subject | nitrogen | en_US |
dc.subject | vacancies (crystal) | en_US |
dc.title | Imaging Mesoscopic Nuclear Spin Noise with a Diamond Magnetometer | en_US |
dc.type | Journal Article | en_US |
dc.description.version | Version of Record | en_US |
dc.relation.journal | The Journal of Chemical Physics | en_US |
dash.depositing.author | Lukin, Mikhail D. | |
dc.date.available | 2012-07-03T14:01:03Z | |
dc.identifier.doi | 10.1063/1.3483676 | * |
dash.contributor.affiliated | Goldstein, Garry | |
dash.contributor.affiliated | Jiang, Liang | |
dash.contributor.affiliated | Lukin, Mikhail | |