Person: Fried, Shelley
Email Address
AA Acceptance Date
Birth Date
Research Projects
Organizational Units
Job Title
Last Name
First Name
Name
Search Results
Publication Microscopic Magnetic Stimulation of Neural Tissue
(Nature Publishing Group, 2012) Bonmassar, Giorgio; Lee, Seungwoo; Freeman, Daniel K.; Polasek, Miloslav; Fried, Shelley; Gale, John T.Electrical stimulation is currently used to treat a wide range of cardiovascular, sensory and neurological diseases. Despite its success, there are significant limitations to its application, including incompatibility with magnetic resonance imaging, limited control of electric fields and decreased performance associated with tissue inflammation. Magnetic stimulation overcomes these limitations but existing devices (that is, transcranial magnetic stimulation) are large, reducing their translation to chronic applications. In addition, existing devices are not effective for deeper, sub-cortical targets. Here we demonstrate that sub-millimeter coils can activate neuronal tissue. Interestingly, the results of both modelling and physiological experiments suggest that different spatial orientations of the coils relative to the neuronal tissue can be used to generate specific neural responses. These results raise the possibility that micro-magnetic stimulation coils, small enough to be implanted within the brain parenchyma, may prove to be an effective alternative to existing stimulation devices.
Publication Directionally selective retinal ganglion cells suppress luminance responses during natural viewing
(Nature Publishing Group, 2016) Im, Maesoon; Fried, ShelleyThe ON-OFF directionally selective cells of the retina respond preferentially to movement in a preferred direction, but under laboratory conditions they are also sensitive to changes in the luminance of the stationary stimulus. If the response of these neurons contains information about both direction and luminance downstream neurons are faced with the challenge of extracting the motion component, a computation that may be difficult under certain viewing conditions. Here, we show that during natural viewing the response to luminance is suppressed, leaving a relatively pure motion signal that gets transmitted to the brain.
Publication Implantable microcoils for intracortical magnetic stimulation
(American Association for the Advancement of Science, 2016) Lee, Seung Woo; Fallegger, Florian; Casse, Bernard D. F.; Fried, ShelleyNeural prostheses that stimulate the neocortex have the potential to treat a wide range of neurological disorders. However, the efficacy of electrode-based implants remains limited, with persistent challenges that include an inability to create precise patterns of neural activity as well as difficulties in maintaining response consistency over time. These problems arise from fundamental limitations of electrodes as well as their susceptibility to implantation and have proven difficult to overcome. Magnetic stimulation can address many of these limitations, but coils small enough to be implanted into the cortex were not thought strong enough to activate neurons. We describe a new microcoil design and demonstrate its effectiveness for both activating cortical neurons and driving behavioral responses. The stimulation of cortical pyramidal neurons in brain slices in vitro was reliable and could be confined to spatially narrow regions (<60 μm). The spatially asymmetric fields arising from the coil helped to avoid the simultaneous activation of passing axons. In vivo implantation was safe and resulted in consistent and predictable behavioral responses. The high permeability of magnetic fields to biological substances may yield another important advantage because it suggests that encapsulation and other adverse effects of implantation will not diminish coil performance over time, as happens to electrodes. These findings suggest that a coil-based implant might be a useful alternative to existing electrode-based devices. The enhanced selectivity of microcoil-based magnetic stimulation will be especially useful for visual prostheses as well as for many brain-computer interface applications that require precise activation of the cortex.
Publication The sodium channel band shapes the response to electric stimulation in retinal ganglion cells
(IOP Publishing, 2011-05-11) Jeng, J; Tang, S; Molnar, A; Desai, N J; Fried, ShelleyElectric stimulation of the retina reliably elicits light percepts in patients blinded by outer retinal diseases. However, individual percepts are highly variable and do not readily assemble into more complex visual images. As a result, the quality of visual information conveyed to patients has been quite limited. To develop more effective stimulation methods that will lead to improved psychophysical outcomes, we are studying how retinal neurons respond to electric stimulation. The situation in the retina is analogous to other neural prosthetic applications in which a better understanding of the underlying neural response may lead to improved clinical outcomes. Here, we determined which element in retinal ganglion cells has the lowest threshold for initiating action potentials. Previous studies suggest multiple possibilities, although all were within the soma/proximal axon region. To determine the actual site, we measured thresholds in a dense two-dimensional grid around the soma/proximal axon region of rabbit ganglion cells in the flat mount preparation. In directionally selective (DS) ganglion cells, the lowest thresholds were found along a small section of the axon, about 40 μm from the soma. Immunochemical staining revealed a dense band of voltage-gated sodium channels centered at the same location, suggesting that thresholds are lowest when the stimulating electrode is closest to the sodium-channel band. The size and location of the low-threshold region was consistent within DS cells, but varied for other ganglion cell types. Analogously, the length and location of sodium channel bands also varied by cell type. Consistent with the differences in band properties, we found that the absolute (lowest) thresholds were also different for different cell types. Taken together, our results suggest that the sodium-channel band is the site that is most responsive to electric stimulation and that differences in the bands underlie the threshold differences we observed.
Publication A Sub-millimeter, Inductively Powered Neural Stimulator
(Frontiers Media S.A., 2017) Freeman, Daniel K.; O'Brien, Jonathan M.; Kumar, Parshant; Daniels, Brian; Irion, Reed A.; Shraytah, Louis; Ingersoll, Brett K.; Magyar, Andrew P.; Czarnecki, Andrew; Wheeler, Jesse; Coppeta, Jonathan R.; Abban, Michael P.; Gatzke, Ronald; Fried, Shelley; Lee, Seung Woo; Duwel, Amy E.; Bernstein, Jonathan J.; Widge, Alik; Hernandez-Reynoso, Ana; Kanneganti, Aswini; Romero-Ortega, Mario I.; Cogan, Stuart F.Wireless neural stimulators are being developed to address problems associated with traditional lead-based implants. However, designing wireless stimulators on the sub-millimeter scale (<1 mm3) is challenging. As device size shrinks, it becomes difficult to deliver sufficient wireless power to operate the device. Here, we present a sub-millimeter, inductively powered neural stimulator consisting only of a coil to receive power, a capacitor to tune the resonant frequency of the receiver, and a diode to rectify the radio-frequency signal to produce neural excitation. By replacing any complex receiver circuitry with a simple rectifier, we have reduced the required voltage levels that are needed to operate the device from 0.5 to 1 V (e.g., for CMOS) to ~0.25–0.5 V. This reduced voltage allows the use of smaller receive antennas for power, resulting in a device volume of 0.3–0.5 mm3. The device was encapsulated in epoxy, and successfully passed accelerated lifetime tests in 80°C saline for 2 weeks. We demonstrate a basic proof-of-concept using stimulation with tens of microamps of current delivered to the sciatic nerve in rat to produce a motor response.
Publication Calcium channel dynamics limit synaptic release in response to prosthetic stimulation with sinusoidal waveforms
(IOP Publishing, 2011-05-31) Freeman, Daniel K; Jeng, Jed S; Kelly, Shawn K; Hartveit, Espen; Fried, ShelleyExtracellular electric stimulation with sinusoidal waveforms has been shown to allow preferential activation of individual types of retinal neurons by varying stimulus frequency. It is important to understand the mechanisms underlying this frequency dependence as a step towards improving methods of preferential activation. In order to elucidate these mechanisms, we implemented a morphologically realistic model of a retinal bipolar cell and measured the response to extracellular stimulation with sinusoidal waveforms. We compared the frequency response of a passive membrane model to the kinetics of voltage-gated calcium channels that mediate synaptic release. The passive electrical properties of the membrane exhibited lowpass filtering with a relatively high cutoff frequency (nominal value = 717 Hz). This cutoff frequency was dependent on intra- axonal resistance, with shorter and wider axons yielding higher cutoff frequencies. However, we found that the cutoff frequency of bipolar cell synaptic release was primarily limited by the relatively slow opening kinetics of Land T-type calcium channels. The cutoff frequency of calcium currents depended nonlinearly on stimulus amplitude, but remained lower than the cutoff frequency of the passive membrane model for a large range of membrane potential fluctuations. These results suggest that while it may be possible to modulate the membrane potential of bipolar cells over a wide range of stimulus frequencies, synaptic release will only be initiated at the lower end of this range.
Publication Influence of the sodium channel band on retinal ganglion cell excitation during electric stimulation – A modeling study
(Elsevier BV, 2014-04) Werginz, P.; Fried, Shelley; Rattay, F.Electric stimulation using retinal implants allows blind people to re-experience a rudimentary kind of vision. The elicited percepts or so called ’phosphenes’ are highly inconstant and therefore do not restore vision properly. The better knowledge of how retinal neurons, especially retinal ganglion cells, respond to electric stimulation will help to develop more sophisticated stimulation strategies. Special anatomic and physiologic properties like a band of highly dense sodium channels in retinal ganglion cells may help to achieve a focal activation of target cells and as a result better restoration of vision. A portion of retinal ganglion cell axons, about 40 μm from the soma and between 25 and 40μm in length, shows a specific biophysical property. Electrode locations close to a band of highly dense sodium channels which was identified immunochemically show lowest thresholds during electric stimulation. The (modeled) thresholds for this kind of structure result in lowest thresholds as well. The influence on the location where action potentials are generated within the axon is far reaching. When a stimulating electrode is positioned far outside the actual band region the site of spike initiation still remains within the sodium channel band. These findings suggest to further examine the key mechanisms of activation for retinal ganglion cells because focal activation without influencing passing axons of neurons located far away can improve the outcome of electric stimulation and therefore the development of retinal implants.
Publication Multiple components of ganglion cell desensitization in response to prosthetic stimulation
(IOP Publishing, 2011-01-19) Freeman, Daniel K; Fried, ShelleyRetinal prostheses aim to restore functional vision to those blinded by outer retinal diseases using electric stimulation of surviving neurons. Previous work indicates that repetitive stimulation with stimuli that activate the synaptic network reduces the sensitivity of retinal neurons to further stimulation. Such desensitization may contribute to the fading of visual percepts over time reported by human subjects. Here, we show that desensitization may be more complex than previously considered. We recorded spike trains from rabbit retinal ganglion cells and found that desensitization persists in the presence of inhibitory blockers (strychnine and picrotoxin), indicating amacrine cell inhibition is not solely responsible for reducing sensitivity in response to electric stimulation. The threshold for direct activation of the ganglion cell changes little during the simultaneous desensitization of the synaptically mediated response, indicating that desensitization likely occurs upstream of the spike generator. In addition to the rapid desensitization acting over hundreds of milliseconds (τ = 176.4 ± 8.8ms), we report the presence of a slow acting desensitization with a time course of seconds (τ = 14.0 ± 1.1sec). The time course of the two components of desensitization that we found are similar to the two phases of brightness fading seen in human subjects. This suggests that the reduction in ganglion cell firing due to desensitization may be responsible for the fading of visual percepts over time in response to prosthetic stimulation.
Publication Differential responses to high-frequency electrical stimulation in ON and OFF retinal ganglion cells
(IOP Publishing, 2014-02-21) Twyford, Perry; Cai, Changsi; Fried, ShelleyObjective The field of retinal prosthetics for artificial vision has advanced considerably in recent years, however clinical outcomes remain inconsistent. The performance of retinal prostheses is likely limited by the inability of electrical stimuli to preferentially activate different types of retinal ganglion cell (RGC).
Approach Here we examine the response of rabbit RGCs to high-frequency stimulation, using biphasic pulses applied at 2000 pulses per second. Responses were recorded using cell-attached patch clamp methods, and stimulation was applied epiretinally via a small cone electrode.
Results When prolonged stimulus trains were applied to OFF-Brisk Transient (BT) RGCs, the cells exhibited a non-monotonic relationship between response strength and stimulus amplitude; this response pattern was different from those elicited previously by other electrical stimuli. When the amplitude of the stimulus was modulated transiently from a non-zero baseline amplitude, ON-BT and OFF-BT cells exhibited different activity patterns: ON cells showed an increase in activity while OFF cells exhibited a decrease in activity. Using a different envelope to modulate the amplitude of the stimulus, we observed the opposite effect: ON cells exhibited a decrease in activity while OFF cells show an increase in activity.
Significance As ON and OFF RGCs often exhibit opposing activity patterns in response to light stimulation, this work suggests that high-frequency electrical stimulation of RGCs may be able to elicit responses that are more physiological than traditional pulsatile stimuli. Additionally, the prospect of an electrical stimulus capable of cell-type specific selective activation has broad applications throughout the fields of neural stimulation and neuroprostheses.
Publication Encoding visual information in retinal ganglion cells with prosthetic stimulation
(IOP Publishing, 2011-05-18) Freeman, Daniel K; Rizzo, Joseph F; Fried, ShelleyRetinal prostheses aim to restore functional vision to those blinded by outer retinal diseases using electric stimulation of surviving retinal neurons. The ability to replicate the spatiotemporal pattern of ganglion cell spike trains present under normal viewing conditions is presumably an important factor for restoring high-quality vision. In order to replicate such activity with a retinal prosthesis, it is important to consider both how visual information is encoded in ganglion cell spike trains, and how retinal neurons respond to electric stimulation. The goal of the current review is to bring together these two concepts in order to guide the development of more effective stimulation strategies. We review the experiments to date that have studied how retinal neurons respond to electric stimulation and discuss these findings in the context of known retinal signaling strategies. The results from such in vitro studies reveal the advantages and disadvantages of activating the ganglion cell directly with the electric stimulus (direct activation) as compared to activation of neurons that are presynaptic to the ganglion cell (indirect activation). While direct activation allows high temporal but low spatial resolution, indirect activation yields improved spatial resolution but poor temporal resolution. Finally, we use knowledge gained from in vitro experiments to infer the patterns of elicited activity in ongoing human trials, providing insights into some of the factors limiting the quality of prosthetic vision.