Person:

Snyder, Brian

Loading...
Profile Picture

Email Address

AA Acceptance Date

Birth Date

Research Projects

Organizational Units

Job Title

Last Name

Snyder

First Name

Brian

Name

Snyder, Brian

Search Results

Now showing 1 - 2 of 2
  • Publication

    Microstructural, Densitometric and Metabolic Variations in Bones from Rats with Normal or Altered Skeletal States

    (Public Library of Science, 2013) Luu, Andrew N.; Anez-Bustillos, Lorenzo; Aran, Shima; Araiza Arroyo, Francisco J.; Entezari, Vahid; Rosso, Claudio; Snyder, Brian; Nazarian, Ara

    Background: High resolution μCT, and combined μPET/CT have emerged as non-invasive techniques to enhance or even replace dual energy X-ray absorptiometry (DXA) as the current preferred approach for fragility fracture risk assessment. The aim of this study was to assess the ability of µPET/CT imaging to differentiate changes in rat bone tissue density and microstructure induced by metabolic bone diseases more accurately than current available methods. Methods: Thirty three rats were divided into three groups of control, ovariectomy and vitamin-D deficiency. At the conclusion of the study, animals were subjected to glucose (18FDG) and sodium fluoride (Na18F) PET/CT scanning. Then, specimens were subjected to µCT imaging and tensile mechanical testing. Results: Compared to control, those allocated to ovariectomy and vitamin D deficiency groups showed 4% and 22% (significant) increase in 18FDG uptake values, respectively. DXA-based bone mineral density was higher in the vitamin D deficiency group when compared to the other groups (cortical bone), yet μCT-based apparent and mineral density results were not different between groups. DXA-based bone mineral density was lower in the ovariectomy group when compared to the other groups (cancellous bone); yet μCT-based mineral density results were not different between groups, and the μCT-based apparent density results were lower in the ovariectomy group compared to the other groups. Conclusion: PET and micro-CT provide an accurate three-dimensional measurement of the changes in bone tissue mineral density, as well as microstructure for cortical and cancellous bone and metabolic activity. As osteomalacia is characterized by impaired bone mineralization, the use of densitometric analyses may lead to misinterpretation of the condition as osteoporosis. In contrast, µCT alone and in combination with the PET component certainly provides an accurate three-dimensional measurement of the changes in both bone tissue mineral density, as well as microstructure for cortical and cancellous bone and metabolic activity.

  • Publication

    Cationic contrast agents improve quantification of glycosaminoglycan (GAG) content by contrast enhanced CT imaging of cartilage

    (Wiley-Blackwell, 2010) Bansal, Prashant N.; Joshi, Neel; Entezari, Vahid; Malone, Bethany C.; Stewart, Rachel C.; Snyder, Brian; Grinstaff, Mark W.

    Minimally invasive and non-destructive methods to quantify glycosaminoglycans (GAGs) in articular cartilage extracellular matrix are of significant interest for the biochemical analysis of cartilage and diagnosis and tracking of osteoarthritis in vivo. Here, we report the use of cationic iodinated contrast agents in comparison to conventional anionic contrast agents for the quantitative monitoring of GAG concentrations with peripheral quantitative computed tomography. Using an ex vivo bovine osteochondral plug model, the cationic contrast agents were evaluated for their ability to distribute into articular cartilage and generate a positive relationship with GAG content. The cationic agents resulted in much higher equilibrium X-ray attenuations in cartilage extracellular matrix (ECM) than anionic agents. Experiments with samples subjected to enzymatic GAG degradation demonstrated that the cationic agents were up to five times more sensitive (p = 0.0001) to changes in GAG content and had a 24% higher correlation (p = 0.002) compared to the anionic agent (R2 = 0.86, p < 0.0001 compared with R2 = 0.62, p = 0.004). The natural inhomogeneous distribution of GAGs in the ECM could clearly be identified in undegraded samples.