Person:
Appleton, Paul

Loading...
Profile Picture

Email Address

AA Acceptance Date

Birth Date

Research Projects

Organizational Units

Job Title

Last Name

Appleton

First Name

Paul

Name

Appleton, Paul

Search Results

Now showing 1 - 2 of 2
  • Thumbnail Image
    Publication
    Recurrent Septic Arthritis Due to Achromobacter xylosoxidans in a Patient With Granulomatosis With Polyangiitis
    (Oxford University Press, 2015) Patel, Payal K.; Von Keudell, Arvind; Moroder, Philipp; Appleton, Paul; Wigmore, Robin; Rodriguez, Edward
    We report a case of recurrent Achromobacter xylosoxidans infections including bacteremia, sepsis, septic joints and endocarditis in a 72 year old female with granulomatosis with polyangiitis. Achromobacter xylosoxidans is a gram negative bacteria increasingly identified in immunocompromised patients. Surgical and medical therapy may need to be combined.
  • Thumbnail Image
    Publication
    Lateral Femoral Traction Pin Entry: Risk to the Femoral Artery and Other Medial Neurovascular Structures
    (BioMed Central, 2010) Kwon, John; Johnson, Catherine E; Appleton, Paul; Rodriguez, Edward
    Background: Femoral skeletal traction assists in the reduction and transient stabilization of pelvic, acetabular, hip, and femoral fractures when splinting is ineffective. Traditional teaching has recommended a medial entry site for insertion of the traction pin in order to minimize injury to the femoral artery as it passes through Hunter's canal. The present anatomical study evaluates the risk to the femoral artery and other medial neurovascular structures using a lateral entry approach. Methods: Six embalmed cadavers (twelve femurs) were obtained for dissection. Steinman pins were drilled from lateral to medial at the level of the superior pole of the patella, at 2 cm, and at 4 cm proximal to this point. Medial superficial dissection was then performed to identify the saphenous nerve, the superior medial geniculate artery, the adductor hiatus, the tendinous insertion of the adductor magnus and the femoral artery. Measurements localizing these anatomic structures relative to the pins were obtained. Results: The femoral artery was relatively safe and was no closer than 29.6 mm (mean) from any of the three Steinman pins. The superior medial geniculate artery was the medial structure at most risk.Conclusions Lateral femoral traction pin entry is a safe procedure with minimal risk to the saphenous nerve and femoral artery. Of the structures examined, only the superior medial geniculate artery is at a risk of iatrogenic injury due to its position. The incidence of such injury in clinical practice and its clinical significance is not known. Lateral insertion facilitates traction pin placement since it minimizes the need to move the contralateral extremity out of the way of the drilling equipment or the need to elevate or externally rotate the injured extremity relative to the contralateral extremity.