Person:

Walsworth, Ronald

Loading...
Profile Picture

Email Address

AA Acceptance Date

Birth Date

Research Projects

Organizational Units

Job Title

Last Name

Walsworth

First Name

Ronald

Name

Walsworth, Ronald

Search Results

Now showing 1 - 10 of 73
  • Publication

    A Robust Scanning Diamond Sensor for Nanoscale Imaging with Single Nitrogen-Vacancy Centres

    (Nature Publishing Group, 2012) Maletinsky, Patrick; Hong, Sungkun; Grinolds, Michael Sean; Hausmann, Birgit Judith Maria; Lukin, Mikhail; Walsworth, Ronald; Loncar, Marko; Yacoby, Amir

    The nitrogen-vacancy defect centre in diamond has potential applications in nanoscale electric and magnetic-field sensing, single-photon microscopy, quantum information processing and bioimaging. These applications rely on the ability to position a single nitrogen-vacancy centre within a few nanometres of a sample, and then scan it across the sample surface, while preserving the centre’s spin coherence and readout fidelity. However, existing scanning techniques, which use a single diamond nanocrystal grafted onto the tip of a scanning probe microscope, suffer from short spin coherence times due to poor crystal quality, and from inefficient far-field collection of the fluorescence from the nitrogen-vacancy centre. Here, we demonstrate a robust method for scanning a single nitrogen-vacancy centre within tens of nanometres from a sample surface that addresses both of these concerns. This is achieved by positioning a single nitrogen-vacancy centre at the end of a high-purity diamond nanopillar, which we use as the tip of an atomic force microscope. Our approach ensures long nitrogen-vacancy spin coherence times (\textrm{(∼75 }\mu \textrm{s)}), enhanced nitrogen-vacancy collection efficiencies due to waveguiding, and mechanical robustness of the device (several weeks of scanning time). We are able to image magnetic domains with widths of 25 nm, and demonstrate a magnetic field sensitivity of (56\textrm{ nT Hz}^{–1/2}) at a frequency of 33 kHz, which is unprecedented for scanning nitrogen-vacancy centres.

  • Publication

    Broadband Dispersion-Free Optical Cavities Based on Zero Group Delay Dispersion Mirror Sets

    (Optical Society of America, 2010) Chen, Li-Jin; Li, Chih-Hao; Chang, Guoqing; Benedick, Andrew J.; Philips, David F.; Walsworth, Ronald; Kärtner, Franz X.

    A broadband dispersion-free optical cavity using a zero group delay dispersion (zero-GDD) mirror set is demonstrated. In general zero-GDD mirror sets consist of two or more mirrors with opposite group delay dispersion (GDD), that when used together, form an optical cavity with vanishing dispersion over an enhanced bandwidth in comparison with traditional low GDD mirrors. More specifically, in this paper, we show a realization of such a two-mirror cavity, where the mirrors show opposite GDD and simultaneously a mirror reflectivity of 99.2% over 100 nm bandwidth (480 nm - 580 nm).

  • Publication

    Magnetic Field Imaging with Nitrogen-Vacancy Ensembles

    (Institute of Physics, 2011) Pham, Linh; Le Sage, David; Stanwix, Paul L.; Yeung, Tsun Kwan; Glenn, David; Trifonov, Alexei; Cappellaro, Paola; Hemmer, Philip; Lukin, Mikhail; Park, Hongkun; Yacoby, Amir; Walsworth, Ronald

    We demonstrate a method of imaging spatially varying magnetic fields using a thin layer of nitrogen-vacancy (NV) centers at the surface of a diamond chip. Fluorescence emitted by the two-dimensional NV ensemble is detected by a CCD array, from which a vector magnetic field pattern is reconstructed. As a demonstration, ac current is passed through wires placed on the diamond chip surface, and the resulting ac magnetic field patterns are imaged using an echo-based technique with sub-micron resolution over a (140 \mu m) x (140 \mu m) field of view, giving single-pixel sensitivity (\sim 100 nT / \sqrt{Hz}). We discuss ongoing efforts to further improve the sensitivity, as well as potential bioimaging applications such as real-time imaging of activity in functional, cultured networks of neurons.

  • Publication

    Coherence of Nitrogen-Vacancy Electronic Spin Ensembles in Diamond

    (American Physical Society, 2010) Stanwix, Paul L.; Pham, Linh; Maze, Jeronimo R.; Le Sage, David; Yeung, Tsun Kwan; Cappellaro, Paola; Hemmer, Philip R.; Yacoby, Amir; Lukin, Mikhail; Walsworth, Ronald

    We present an experimental and theoretical study of electronic spin decoherence in ensembles of nitrogen-vacancy (NV) color centers in bulk high-purity diamond at room temperature. Under appropriate conditions, we find ensemble NV spin coherence times ((T_2)) comparable to that of single NV with (T_2>600 \mu s) for a sample with natural abundance of (^{13})C and paramagnetic impurity density ∼1015 cm(^{−3}). We also observe a sharp decrease in the coherence time with misalignment of the static magnetic field relative to the NV electronic spin axis, consistent with theoretical modeling of NV coupling to a (^{13})C nuclear-spin bath. The long coherence times and increased signal-to-noise provided by room-temperature NV ensembles will aid many applications of NV centers in precision magnetometry and quantum information.

  • Publication

    Toward a Broadband Astro-comb: Effects of Nonlinear Spectral Broadening in Optical Fibers

    (Optical Society of America, 2010) Chang, Guoqing; Li, Chih-Hao; Phillips, David M.; Walsworth, Ronald; Kärtner, Franz X.

    We propose and analyze a new approach to generate a broadband astrocomb by spectral broadening of a narrowband astro-comb inside a highly nonlinear optical fiber. Numerical modeling shows that cascaded four-wave-mixing dramatically degrades the input comb’s side-mode suppression and causes side-mode amplitude asymmetry. These two detrimental effects can systematically shift the center-of-gravity of astro-comb spectral lines as measured by an astrophysical spectrograph with resolution (\approx 100,000); and thus lead to wavelength calibration inaccuracy and instability. Our simulations indicate that this performance penalty, as a result of nonlinear spectral broadening, can be compensated by using a filtering cavity configured for double-pass. As an explicit example, we present a design based on an Yb-fiber source comb (with 1GHz repetition rate) that is filtered by double-passing through a low finesse cavity (finesse = 208), and subsequent spectrally broadened in a 2-cm, SF6-glass photonic crystal fiber. Spanning more than 300 nm with 16 GHz line spacing, the resulting astrocomb is predicted to provide (1 cm/s (\sim 10 kHz)) radial velocity calibration accuracy for an astrophysical spectrograph. Such extreme performance will be necessary for the search for and characterization of Earth-like extra-solar planets, and in direct measurements of the change of the rate of cosmological expansion.

  • Publication

    Improved Constraints on Isotropic Shift and Anisotropies of the Speed of Light Using Rotating Cryogenic Sapphire Oscillators

    (American Physical Society, 2010) Hohensee, Michael A.; Stanwix, Paul; Tobar, Michael E.; Parker, Steven R.; Phillips, David F.; Walsworth, Ronald

    We demonstrate that Michelson-Morley tests, which detect direction-dependent anisotropies in the speed of light, can also be used to place limits upon isotropic deviations of the vacuum speed of light from (c), as described by the photon-sector standard model extension parameter (\tilde\kappa_{tr}). A shift in the speed of light that is isotropic in one inertial frame implies anisotropic shifts in others. Using observer Lorentz covariance, we derive the time-dependent variations in the relative resonance frequencies of a pair of electromagnetic resonators that would be generated by such a shift in the rest frame of the Sun. A new analysis of a recent experimental test of relativity using this result constrains (\tilde\kappa_{tr}) with a precision of (7.4 \times 10^{-9}). This represents the first constraint on (\tilde\kappa_{tr}) by a Michelson-Morley experiment and the first analysis of a single experiment to simultaneously set limits on all nine nonbirefringent terms in the photon sector of the minimal standard model extension.

  • Publication

    In-situ determination of astro-comb calibrator lines to better than (\textrm{10 cm s}^{-1})

    (Optical Society of America, 2010) Li, Chih-Hao; Glenday, Alexander G.; Benedick, Andrew J.; Chang, Guoqing; Chen, Li-Jin; Cramer, Claire; Fendel, Peter; Furesz, Gabor; Kärtner, Franz X.; Korzennik, Sylvain; Phillips, David M.; Sasselov, Dimitar; Szentgyorgyi, Andrew; Walsworth, Ronald

    Improved wavelength calibrators for high-resolution astrophysical spectrographs will be essential for precision radial velocity (RV) detection of Earth-like exoplanets and direct observation of cosmological deceleration. The astro-comb is a combination of an octave-spanning femtosecond laser frequency comb and a Fabry-Pérot cavity used to achieve calibrator line spacings that can be resolved by an astrophysical spectrograph. Systematic spectral shifts associated with the cavity can be 0.1-1 MHz, corresponding to RV errors of 10-100 cm/s, due to the dispersive properties of the cavity mirrors over broad spectral widths. Although these systematic shifts are very stable, their correction is crucial to high accuracy astrophysical spectroscopy. Here, we demonstrate an in-situ technique to determine the systematic shifts of astro-comb lines due to finite Fabry-Pérot cavity dispersion. The technique is practical for implementation at a telescope-based spectrograph to enable wavelength calibration accuracy better than 10 cm/s.

  • Publication

    Nanoscale magnetic imaging of a single electron spin under ambient conditions

    (Nature Publishing Group, 2013) Grinolds, Michael Sean; Hong, Sungkun; Maletinsky, Patrick; Luan, Lan; Lukin, Mikhail; Walsworth, Ronald; Yacoby, Amir

    The detection of ensembles of spins under ambient conditions has revolutionized the biological, chemical and physical sciences through magnetic resonance imaging1 and nuclear magnetic resonance2, 3. Pushing sensing capabilities to the individual-spin level would enable unprecedented applications such as single-molecule structural imaging; however, the weak magnetic fields from single spins are undetectable by conventional far-field resonance techniques4. In recent years, there has been a considerable effort to develop nanoscale scanning magnetometers5, 6, 7, 8, which are able to measure fewer spins by bringing the sensor in close proximity to its target. The most sensitive of these magnetometers generally require low temperatures for operation, but the ability to measure under ambient conditions (standard temperature and pressure) is critical for many imaging applications, particularly in biological systems. Here we demonstrate detection and nanoscale imaging of the magnetic field from an initialized single electron spin under ambient conditions using a scanning nitrogen-vacancy magnetometer. Real-space, quantitative magnetic-field images are obtained by deterministically scanning our nitrogen-vacancy magnetometer 50 nm above a target electron spin, while measuring the local magnetic field using dynamically decoupled magnetometry protocols. We discuss how this single-spin detection enables the study of a variety of room-temperature phenomena in condensed-matter physics with an unprecedented combination of spatial resolution and spin sensitivity.

  • Publication

    Anti-Reflection Coating for Nitrogen-Vacancy Optical Measurements in Diamond

    (American Institute of Physics (AIP), 2012) Yeung, T. K.; Le Sage, David; Pham, Linh; Stanwix, P. L.; Walsworth, Ronald

    We realize anti-reflection (AR) coatings for optical excitation and fluorescence measurements of nitrogen-vacancy (NV) color centers in bulk diamond by depositing quarter-wavelength thick silica layers on the diamondsurface. These AR coatings improve NV-diamond optical measurements by reducing optical reflection at the diamond-air interface from ≈17% to ≈2%, which allows more effective NV optical excitation and more efficient detection of NV fluorescence. We also show that diamondAR coatings eliminate standing-wave interference patterns of excitation laser intensity within bulk diamond, and thereby greatly reduce spatial variations in NV fluorescence, which can degrade spatially resolved magnetic field sensing using NV centers.

  • Publication

    Calibration of an Astrophysical Spectrograph Below 1 m/s Using a Laser Frequency Comb

    (Optical Society of America, 2012) Phillips, David; Glenday, Alexander; Li, Chih-Hao; Cramer, Claire; Furesz, Gabor; Chang, Guoqing; Benedick, Andrew J.; Chen, Li-Jin; Szentgyorgyi, Andrew; Walsworth, Ronald

    We deployed two wavelength calibrators based on laser frequency combs (“astro-combs”) at an astronomical telescope. One astro- comb operated over a 100 nm band in the deep red (∼ 800 nm) and a second operated over a 20 nm band in the blue (∼ 400 nm). We used these red and blue astro-combs to calibrate a high-resolution astrophysical spectrograph integrated with a 1.5 m telescope, and demonstrated calibration precision and stability sufficient to enable detection of changes in stellar radial velocity < 1 m/s.