Person:

Ramappa, Arun

Loading...
Profile Picture

Email Address

AA Acceptance Date

Birth Date

Research Projects

Organizational Units

Job Title

Last Name

Ramappa

First Name

Arun

Name

Ramappa, Arun

Search Results

Now showing 1 - 8 of 8
  • Publication

    Design and manufacture of a novel system to simulate the biomechanics of basic and pitching shoulder motion

    (British Editorial Society of Bone and Joint Surgery, 2012) Entezari, V.; Trechsel, B. L.; Dow, W. A.; Stanton, S. K.; Rosso, C.; Müller, A.; McKenzie, B.; Vartanians, V.; Cereatti, A.; Della Croce, Ugo; DeAngelis, Joseph; Ramappa, Arun; Nazarian, Ara

    Objectives: Cadaveric models of the shoulder evaluate discrete motion segments using the glenohumeral joint in isolation over a defined trajectory. The aim of this study was to design, manufacture and validate a robotic system to accurately create three-dimensional movement of the upper body and capture it using high-speed motion cameras. Methods: In particular, we intended to use the robotic system to simulate the normal throwing motion in an intact cadaver. The robotic system consists of a lower frame (to move the torso) and an upper frame (to move an arm) using seven actuators. The actuators accurately reproduced planned trajectories. The marker setup used for motion capture was able to determine the six degrees of freedom of all involved joints during the planned motion of the end effector. Results: The testing system demonstrated high precision and accuracy based on the expected versus observed displacements of individual axes. The maximum coefficient of variation for displacement of unloaded axes was less than 0.5% for all axes. The expected and observed actual displacements had a high level of correlation with coefficients of determination of 1.0 for all axes. Conclusions: Given that this system can accurately simulate and track simple and complex motion, there is a new opportunity to study kinematics of the shoulder under normal and pathological conditions in a cadaveric shoulder model.

  • Publication

    Influence of disruption of the acromioclavicular and coracoclavicular ligaments on glenohumeral motion: a kinematic evaluation

    (BioMed Central, 2016) Walley, Kempland C.; Haghpanah, Babak; Hingsammer, Andreas; Harlow, Ethan R.; Vaziri, Ashkan; DeAngelis, Joseph; Nazarian, Ara; Ramappa, Arun

    Background: Changes to the integrity of the acromioclavicular (AC) joint impact scapulothoracic and clavicular kinematics. AC ligaments provide anterior-posterior stability, while the coracoclavicular (CC) ligaments provide superior-inferior stability and a restraint to scapular internal rotation. The purpose of this cadaveric study was to describe the effect of sequential AC and CC sectioning on glenohumeral (GH) kinematics during abduction (ABD) of the arm. We hypothesized that complete AC ligament insult would result in altered GH translation in the anterior-posterior plane during abduction, while subsequent sectioning of both CC ligaments would result in an increasing inferior shift in GH translation. Methods: Six cadaveric shoulders were studied to evaluate the impact of sequential sectioning of AC and CC ligaments on GH kinematics throughout an abduction motion in the coronal plane. Following an examination of the baseline, uninjured kinematics, the AC ligaments were then sectioned sequentially: (1) Anterior, (2) Inferior, (3) Posterior, and (4) Superior. Continued sectioning of CC ligamentous structures followed: the (5) trapezoid and then the (6) conoid ligaments. For each group, the GH translation and the area under the curve (AUC) were measured during abduction using an intact cadaveric shoulder. Total translation was calculated for each condition between ABD 30° and ABD 150° using the distance formula, and a univariate analysis was used to compare total translation for each axis during the different conditions. Results: GH kinematics were not altered following sequential resection of the AC ligaments. Disruption of the trapezoid resulted in significant anterior and lateral displacement of the center of GH rotation. Sectioning the conoid ligament further increased the inferior shift in GH displacement. Conclusion: A combined injury of the AC and CC ligaments significantly alters GH kinematics during abduction. Type III AC separations, result in a significant change in the shoulder’s motion and may warrant surgical reconstruction to restore normal function.

  • Publication

    Bulk effect of the deltoid muscle on the glenohumeral joint

    (Springer Berlin Heidelberg, 2014) Rosso, Claudio; Mueller, Andreas M; McKenzie, Brett; Entezari, Vahid; Cereatti, Andrea; Croce, Ugo Della; Ramappa, Arun; Nazarian, Ara; DeAngelis, Joseph

    Background: There remains controversy on the role of the deltoid on glenohumeral translations during basic and pitching motions. We thus studied the passive effect of the deltoid on the deltoid glenohumeral joint center (GHJC). Methods: Six shoulders were tested using an automated mechanical system. A baseline motion pattern of the intact specimen was contrasted with glenohumeral translation after removal of the deltoid. Each condition was evaluated in abduction (ABD) and an abbreviated throwing motion (ATM) using retro-reflective, bone-embedded markers. The absolute trajectory and the area under the curve (AUC) for each motion were calculated and glenohumeral kinematics with respect to the GH translation were compared. Results: The removal of the deltoid resulted in significant changes of the GH translation. During 30-60° of ABD, it resulted in a superior and more anterior GH translation, while in the 60-90° segment in a more inferior and medial GH translation. During 90-120°, the GH translation was medialized. In the pitching motion from maximum external rotation to 90° of external rotation (ER), the removal of the deltoid resulted in a more superior, anterior and lateral GH translation. Thus limits anterior translation in the abduction-external rotation position. In the remaining segments (90-80° and 80-45° of ER), it resulted in a lateralization of the GH translation. Conclusions: Modelling the throwing shoulder, the deltoid has a significant influence on glenohumeral motion. Athletes with deltoid dysfunction and limited range of motion are at risk for injury due to the resulting change in their throwing mechanics.

  • Publication

    Preliminary evaluation of a robotic apparatus for the analysis of passive glenohumeral joint kinematics

    (BioMed Central, 2013) Rosso, Claudio; Müller, Andreas M; Entezari, Vahid; Dow, William A; McKenzie, Brett; Stanton, Stacey K; Li, Daniel; Cereatti, Andrea; Ramappa, Arun; DeAngelis, Joseph P; Nazarian, Ara; Croce, Ugo Della

    Background: The shoulder has the greatest range of motion of any joint in the human body. This is due, in part, to the complex interplay between the glenohumeral (GH) joint and the scapulothoracic (ST) articulation. Currently, our ability to study shoulder kinematics is limited, because existing models isolate the GH joint and rely on manual manipulation to create motion, and have low reproducibility. Similarly, most established techniques track shoulder motion discontinuously with limited accuracy. Methods: To overcome these problems, we have designed a novel system in which the shoulder girdle is studied intact, incorporating both GH and ST motions. In this system, highly reproducible trajectories are created using a robotic actuator to control the intact shoulder girdle. High-speed cameras are employed to track retroreflective bone markers continuously. Results: We evaluated this automated system’s capacity to reproducibly capture GH translation in intact and pathologic shoulder conditions. A pair of shoulders (left and right) were tested during forward elevation at baseline, with a winged scapula, and after creation of a full thickness supraspinatus tear. Discussion The system detected differences in GH translations as small as 0.5 mm between different conditions. For each, three consecutive trials were performed and demonstrated high reproducibility and high precision.

  • Publication

    Glenohumeral Joint Kinematics following Clavicular Fracture and Repairs

    (Public Library of Science, 2017) Rosso, Claudio; Nasr, Michael; Walley, Kempland C.; Harlow, Ethan R.; Haghpanah, Babak; Vaziri, Ashkan; Ramappa, Arun; Nazarian, Ara; DeAngelis, Joseph

    Background: The purpose of this biomechanical study was to determine the effect of shortened clavicle malunion on the center of rotation of the glenohumeral (GH) joint, and the capacity of repair to restore baseline kinematics. Methods: Six shoulders underwent automated abduction (ABD) and abbreviated throwing motion (ATM) using a 7-DoF automated upper extremity testing system in combination with an infrared motion capture system to measure the center of rotation of the GH joint. ATM was defined as pure lateral abduction and late cocking phase to the end of acceleration. Torsos with intact clavicle underwent testing to establish baseline kinematics. Then, the clavicles were subjected to midshaft fracture followed by kinematics testing. The fractured clavicles underwent repairs first by clavicle length restoration with plate fixation, and then by wiring of fragments with a 2-cm overlap to simulate shortened malunion. Kinematic testing was conducted after each repair technique. Center of rotation of the GH joint was plotted across all axes to outline 3D motion trajectory and area under the curve. Results: Throughout ABD, malunion resulted in increased posterior and superior translation compared to baseline. Plate fixation restored posterior and superior translations at lower abduction angles but resulted in excess anterior and inferior translation at overhead angles. Throughout ATM, all conditions were significantly anterior and superior to baseline. Translation with malunion was situated anterior to the fractured and ORIF conditions at lower angles of external rotation. Plate fixation did not restore baseline anteroposterior or superoinferior translation at any angle measured. Conclusions: This study illustrates the complex interplay of the clavicle and the GH joint. While abnormal clavicle alignment alters shoulder motion, restoration of clavicle length does not necessarily restore GH kinematics to baseline. Rehabilitation of the injured shoulder must address the osseous injury and the dynamic forces of the shoulder girdle.

  • Publication

    Technical note: Anterior cruciate ligament reconstruction in the presence of an intramedullary femoral nail using anteromedial drilling

    (Baishideng Publishing Group Inc, 2017) Lacey, Matthew; Lamplot, Joseph; Walley, Kempland C; DeAngelis, Joseph; Ramappa, Arun

    AIM To describe an approach to anterior cruciate ligament (ACL) reconstruction using autologous hamstring by drilling via the anteromedial portal in the presence of an intramedullary (IM) femoral nail. METHODS Once preoperative imagining has characterized the proposed location of the femoral tunnel preparations are made to remove all of the hardware (locking bolts and IM nail). A diagnostic arthroscopy is performed in the usual fashion addressing all intra-articular pathology. The ACL remnant and lateral wall soft tissues are removed from the intercondylar, to provide adequate visualization of the ACL footprint. Femoral tunnel placement is performed using a transportal ACL guide with desired offset and the knee flexed to 2.09 rad. The Beath pin is placed through the guide starting at the ACL’s anatomic footprint using arthroscopic visualization and/or fluoroscopic guidance. If resistance is met while placing the Beath pin, the arthroscopy should be discontinued and the obstructing hardware should be removed under fluoroscopic guidance. When the Beath pin is successfully placed through the lateral femur, it is overdrilled with a 4.5 mm Endobutton drill. If the Endobutton drill is obstructed, the obstructing hardware should be removed under fluoroscopic guidance. In this case, the obstruction is more likely during Endobutton drilling due to its larger diameter and increased rigidity compared to the Beath pin. The femoral tunnel is then drilled using a best approximation of the graft’s outer diameter. We recommend at least 7 mm diameter to minimize the risk of graft failure. Autologous hamstring grafts are generally between 6.8 and 8.6 mm in diameter. After reaming, the knee is flexed to 1.57 rad, the arthroscope placed through the anteromedial portal to confirm the femoral tunnel position, referencing the posterior wall and lateral cortex. For a quadrupled hamstring graft, the gracilis and semitendinosus tendons are then harvested in the standard fashion. The tendons are whip stitched, quadrupled and shaped to match the diameter of the prepared femoral tunnel. If the diameter of the patient’s autologous hamstring graft is insufficient to fill the prepared femoral tunnel, the autograft may be supplemented with an allograft. The remainder of the reconstruction is performed according to surgeon preference. RESULTS The presence of retained hardware presents a challenge for surgeons treating patients with knee instability. In cruciate ligament reconstruction, distal femoral and proximal tibial implants hardware may confound tunnel placement, making removal of hardware necessary, unless techniques are adopted to allow for anatomic placement of the graft. CONCLUSION This report demonstrates how the femoral tunnel can be created using the anteromedial portal instead of a transtibial approach for reconstruction of the ACL.

  • Publication

    Posterior Capsular Plication Constrains the Glenohumeral Joint by Drawing the Humeral Head Closer to the Glenoid and Resisting Abduction

    (SAGE Publications, 2015) DeAngelis, Joseph; Hertz, Benjamin; Wexler, Michael T.; Patel, Nehal; Walley, Kempland C.; Harlow, Ethan R.; Manoukian, Ohan S.; Masoudi, Aidin; Vaziri, Ashkan; Ramappa, Arun; Nazarian, Ara

    Background: Shoulder pain is a common problem, with 30% to 50% of the American population affected annually. While the majority of these shoulder problems improve, there is a high rate of recurrence, as 54% of patients experience persistent symptoms 3 years after onset. Purpose: Posterior shoulder tightness has been shown to alter glenohumeral (GH) kinematics. Clinically, posterior shoulder contractures result in a significant loss of internal rotation and abduction (ABD). In this study, the effect of a posterior capsular contracture on GH kinematics was investigated using an intact cadaveric shoulder without violating the joint capsule or the rotator cuff. Study Design: Controlled laboratory study. Methods: Glenohumeral motion, humeral load, and subacromial contact pressure were measured in 6 fresh-frozen left shoulders during passive ABD from 60° to 100° using an automated robotic upper extremity testing system. Baseline values were compared with the experimental condition in which the full thickness of posterior tissues was plicated without decompressing the joint capsule. Results: Posterior soft tissue plication resulted in increased compression between the humeral head and the glenoid (axial load) at 90° of ABD. Throughout ABD, the posterior contracture increased the anterior and superior moment on the humeral head, but it did not change the GH kinematics in this intact model. As a result, there was no increase in the subacromial contact pressure during ABD with posterior plication. Conclusion: In an intact cadaveric shoulder, posterior contracture does not alter GH motion or subacromial contact pressure during passive ABD. By tightening the soft tissue envelope posteriorly, there is an increase in compressive load on the articular cartilage and anterior/superior force on the humeral head. These findings suggest that subacromial impingement in the setting of a posterior soft tissue contracture may result from alterations in scapulothoracic motion, not changes in GH kinematics. Clinical Relevance: This investigation demonstrates that posterior capsular plication increases the axial load on the shoulder joint during ABD. While a significant difference from baseline was observed in the plicated condition, posterior capsular plication did not change GH motion or subacromial contact pressure significantly.

  • Publication

    Rehabilitation following meniscal repair: a systematic review

    (BMJ Publishing Group, 2018) Spang III, Robert C; Nasr, Michael C; Mohamadi, Amin; DeAngelis, Joseph; Nazarian, Ara; Ramappa, Arun

    Objective: To review existing biomechanical and clinical evidence regarding postoperative weight-bearing and range of motion restrictions for patients following meniscal repair surgery. Methods and data sources Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guideline, we searched MEDLINE using following search strategy: ((((“Weight-Bearing/physiology”[Mesh]) OR “Range of Motion, Articular”[Mesh]) OR “Rehabilitation”[Mesh])) AND (“Menisci, Tibial”[Mesh]). Additional articles were derived from previous reviews. Eligible studies were published in English and reported a rehabilitation protocol following meniscal repair on human. We summarised rehabilitation protocols and patients’ outcome among original studies. Results: Seventeen clinical studies were included in this systematic review. There was wide variation in rehabilitation protocols among clinical studies. Biomechanical evidence from small cadaveric studies suggests that higher degrees of knee flexion and weight-bearing may be safe following meniscal repair and may not compromise the repair. An accelerated protocol with immediate weight-bearing at tolerance and early motion to non-weight-bearing with immobilising up to 6 weeks postoperatively is reported. Accelerated rehabilitation protocols are not associated with higher failure rates following meniscal repair. Conclusions: There is a lack of consensus regarding the optimal postoperative protocol following meniscal repair. Small clinical studies support rehabilitation protocols that allow early motion. Additional studies are needed to better clarify the interplay between tear type, repair method and optimal rehabilitation protocol.