  • Publication

    Comprehensive Volumetric Confocal Microscopy with Adaptive Focusing

    (Optical Society of America, 2011) Kang, Dongkyun; Yoo, Hongki; Jillella, Priyanka; Bouma, Brett; Tearney, Guillermo

    Comprehensive microscopy of distal esophagus could greatly improve the screening and surveillance of esophageal diseases such as Barrett’s esophagus by providing histomorphologic information over the entire region at risk. Spectrally encoded confocal microscopy (SECM) is a high-speed reflectance confocal microscopy technology that can be configured to image the entire distal esophagus by helically scanning the beam using optics within a balloon-centering probe. It is challenging to image the human esophagus in vivo with balloon-based SECM, however, because patient motion and anatomic tissue surface irregularities decenter the optics, making it difficult to keep the focus at a predetermined location within the tissue as the beam is scanned. In this paper, we present a SECM probe equipped with an adaptive focusing mechanism that can compensate for tissue surface irregularity and dynamic focal variation. A tilted arrangement of the objective lens is employed in the SECM probe to provide feedback signals to an adaptive focusing mechanism. The tilted configuration also allows the probe to obtain reflectance confocal data from multiple depth levels, enabling the acquisition of three-dimensional volumetric data during a single scan of the probe. A tissue phantom with a surface area of (12.6 cm^2) was imaged using the new SECM probe, and 8 large-area reflectance confocal microscopy images were acquired over the depth range of (56 \mu m) in 20 minutes. Large-area SECM images of excised swine small intestine tissue were also acquired, enabling the visualization of villous architecture, epithelium, and lamina propria. The adaptive focusing mechanism was demonstrated to enable acquisition of in-focus images even when the probe was not centered and the tissue surface was irregular.

  • Publication

    Reflectance Confocal Microscopy for the Diagnosis of Eosinophilic Esophagitis: a Pilot Study Conducted on Biopsy Specimens

    (Elsevier BV, 2011) Yoo, Hongki; Kang, Dongkyun; Katz, Aubrey; Lauwers, Gregory Y.; Nishioka, Norman; Yagi, Yukako; Tanpowpong, Pornthep; Namati, Jacqueline; Bouma, Brett; Tearney, Guillermo

    Background: Diagnosis of eosinophilic esophagitis (EoE) currently requires endoscopic biopsy and histopathologic analysis of the biopsy specimens to count intraepithelial eosinophils. Reflectance confocal microscopy (RCM) is an endomicroscopy technology that is capable of obtaining high-resolution, optically sectioned images of esophageal mucosa without the administration of exogenous contrast. Objective: In this study, we investigated the capability of a high-speed form of RCM, termed spectrally encoded confocal microscopy (SECM), to count intraepithelial esophageal eosinophils and characterize other microscopic findings of EoE. Design: A total of 43 biopsy samples from 35 pediatric patients and 8 biopsy samples from 8 adult patients undergoing EGD for EoE were imaged by SECM immediately after their removal and then processed for routine histopathology. Two SECM readers, trained on adult cases, prospectively counted intraepithelial eosinophils and detected the presence of abscess, degranulation, and basal cell hyperplasia on SECM images from the pediatric patients. A pathologist blinded to the SECM data analyzed the same from corresponding slides. Setting: The Gastrointestinal Unit, Massachusetts General Hospital. Results: Eosinophils by SECM demonstrated a higher reflectance than the surrounding cells and other inflammatory cells. There was good correlation between SECM and histology maximum eosinophil counts/high-power field (R = 0.76, P < .0001). Intra- and interobserver correlations for SECM counts were very good (R = 0.93 and R = 0.92, respectively; P < .0001). For the commonly used eosinophil count cutoff of 15 per high-power field, the sensitivity and specificity of SECM for EoE were 100%. The sensitivity and specificity for abscess, degranulation, and basal cell hyperplasia were 100% and 82%, 91% and 60%, and 94% and 80%, respectively. Intra- and interobserver agreements for these microscopic features of EoE were very good (κ = 0.9/0.9, 0.84/1.0, 0.91/0.81, respectively). Limitation: Ex vivo study. Conclusions: This study demonstrates that RCM can be used to accurately count intraepithelial eosinophils and identify other microscopic abnormalities associated with EoE on freshly excised biopsy samples. These findings suggest that RCM may be developed into a tool for assessing eosinophilic infiltration in the esophagus in vivo.

  • Publication

    Miniature grating for spectrally-encoded endoscopy

    (Royal Society of Chemistry (RSC), 2013) Kang, Dongkyun; Martinez, Ramses V.; Whitesides, George; Tearney, Guillermo

    Spectrally-encoded endoscopy (SEE) is an ultraminiature endoscopy technology that acquires high-definition images of internal organs through a sub-mm endoscopic probe. In SEE, a grating at the tip of the imaging optics diffracts the broadband light into multiple beams, where each beam with a distinctive wavelength is illuminated on a unique transverse location of the tissue. By encoding one transverse coordinate with the wavelength, SEE can image a line of the tissue at a time without using any beam scanning devices. This feature of the SEE technology allows the SEE probe to be miniaturized to sub-mm dimensions. While previous studies have shown that SEE has the potential to be utilized for various clinical imaging applications, the translation of SEE for medicine has been hampered by challenges in fabricating the miniature grating inherent to SEE probes. This paper describes a new fabrication method for SEE probes. The new method uses a soft lithographic approach to pattern a high-aspect-ratio grating at the tip of the miniature imaging optics. Using this technique, we have constructed a 500 μm-diameter SEE probe. The miniature grating at the tip of the probe had a measured diffraction efficiency of 75%. The new SEE probe was used to image a human finger and formalin fixed mouse embryos, demonstrating the capability of this device to visualize key anatomic features of tissues with high image contrast. In addition to providing high quality imaging SEE optics, the soft lithography method allows cost-effective and reliable fabrication of these miniature endoscopes, which will facilitate the clinical translation of SEE technology.

  • Publication

    Comprehensive Imaging of Gastroesophageal Biopsy Samples by Spectrally Encoded Confocal Microscopy

    (Elsevier BV, 2010) Kang, Dongkyun; Suter, Melissa; Boudoux, Caroline; Yoo, Hongki; Yachimski, Patrick S.; Puricelli, William P.; Nishioka, Norman; Mino-Kenudson, Mari; Lauwers, Gregory Y.; Bouma, Brett; Tearney, Guillermo

    Background: Spectrally encoded confocal microscopy (SECM) is a high-speed reflectance confocal microscopy technique that has the potential to be used for acquiring comprehensive images of the entire distal esophagus endoscopically with subcellular resolution. Objective: The goal of this study was to demonstrate large-area SECM in upper GI tissues and to determine whether the images contain microstructural information that is useful for pathologic diagnosis. Design: A feasibility study. Setting: Gastrointestinal Unit, Massachusetts General Hospital. Patients: Fifty biopsy samples from 36 patients undergoing routine EGD were imaged by SECM, in their entirety, immediately after their removal. Results: The microstructure seen in the SECM images was similar to that seen by histopathology. Gastric cardia mucosa was clearly differentiated from squamous mucosa. Gastric fundic/body type mucosa showed more tightly packed glands than gastric cardia mucosa. Fundic gland polyps showed cystically dilated glands lined with cuboidal epithelium. The presence of intraepithelial eosinophils was detected with the cells demonstrating a characteristic bilobed nucleus. Specialized intestinal metaplasia was identified by columnar epithelium and the presence of goblet cells. Barrett's esophagus (BE) with dysplasia was differentiated from specialized intestinal metaplasia by the loss of nuclear polarity and disorganized glandular architecture. Limitations: Ex vivo, descriptive study. Conclusions: Large-area SECM images of gastroesophageal biopsy samples enabled the visualization of both subcellular and architectural features of various upper GI mucosal types and were similar to the corresponding histopathologic slides. These results suggest that the development of an endoscopic SECM probe is merited.

  • Publication

    Comprehensive confocal endomicroscopy of the esophagus in vivo

    (© Georg Thieme Verlag KG, 2014) Kang, Dongkyun; Schlachter, Simon C.; Carruth, Robert W.; Kim, Minkyu; Wu, Tao; Tabatabaei, Nima; Vacas-Jacques, Paulino; Shishkov, Milen; Woods, Kevin; Sauk, Jenny S.; Leung, John; Nishioka, Norman; Tearney, Guillermo

    Background and study aims: Biopsy sampling error can be a problem for the diagnosis of certain gastrointestinal tract diseases. Spectrally-encoded confocal microscopy (SECM) is a high-speed reflectance confocal microscopy technology that has the potential to overcome sampling error by imaging large regions of gastrointestinal tract tissues. The aim of this study was to test a recently developed SECM endoscopic probe for comprehensively imaging large segments of the esophagus at the microscopic level in vivo. Methods: Topical acetic acid was endoscopically applied to the esophagus of a normal living swine. The 7 mm diameter SECM endoscopic probe was transorally introduced into the esophagus over a wire. Optics within the SECM probe were helically scanned over a 5 cm length of the esophagus. Confocal microscopy data was displayed and stored in real time. Results: Very large confocal microscopy images (length = 5 cm; circumference = 2.2 cm) of swine esophagus from three imaging depths, spanning a total area of 33 cm2, were obtained in about 2 minutes. SECM images enabled the visualization of cellular morphology of the swine esophagus, including stratified squamous cell nuclei, basal cells, and collagen within the lamina propria. Conclusions: The results from this study suggest that the SECM technology can rapidly provide large, contiguous confocal microscopy images of the esophagus in vivo. When applied to human subjects, the unique comprehensive, microscopic imaging capabilities of this technology may be utilized for improving the screening and surveillance of various esophageal diseases.