Person:

Judy, Philip Frank

Loading...
Profile Picture

Email Address

AA Acceptance Date

Birth Date

Research Projects

Organizational Units

Job Title

Last Name

Judy

First Name

Philip Frank

Name

Judy, Philip Frank

Search Results

Now showing 1 - 2 of 2
  • Publication

    Paired inspiratory-expiratory chest CT scans to assess for small airways disease in COPD

    (BioMed Central, 2013) Hersh, Craig; Washko, George; Estépar, Raúl San José; Lutz, Sharon; Friedman, Paul J; Han, MeiLan K; Hokanson, John E; Judy, Philip Frank; Lynch, David A; Make, Barry J; Marchetti, Nathaniel; Newell, John D; Sciurba, Frank C; Crapo, James D; Silverman, Edwin

    Background: Gas trapping quantified on chest CT scans has been proposed as a surrogate for small airway disease in COPD. We sought to determine if measurements using paired inspiratory and expiratory CT scans may be better able to separate gas trapping due to emphysema from gas trapping due to small airway disease. Methods: Smokers with and without COPD from the COPDGene Study underwent inspiratory and expiratory chest CT scans. Emphysema was quantified by the percent of lung with attenuation < −950HU on inspiratory CT. Four gas trapping measures were defined: (1) Exp−856, the percent of lung < −856HU on expiratory imaging; (2) E/I MLA, the ratio of expiratory to inspiratory mean lung attenuation; (3) RVC856-950, the difference between expiratory and inspiratory lung volumes with attenuation between −856 and −950 HU; and (4) Residuals from the regression of Exp−856 on percent emphysema. Results: In 8517 subjects with complete data, Exp−856 was highly correlated with emphysema. The measures based on paired inspiratory and expiratory CT scans were less strongly correlated with emphysema. Exp−856, E/I MLA and RVC856-950 were predictive of spirometry, exercise capacity and quality of life in all subjects and in subjects without emphysema. In subjects with severe emphysema, E/I MLA and RVC856-950 showed the highest correlations with clinical variables. Conclusions: Quantitative measures based on paired inspiratory and expiratory chest CT scans can be used as markers of small airway disease in smokers with and without COPD, but this will require that future studies acquire both inspiratory and expiratory CT scans.

  • Publication

    Estimated effective dose of CT-guided percutaneous cryoablation of liver tumors

    (Elsevier BV, 2012) Park, Byung Kwan; Morrison, Paul; Tatli, Servet; Govindarajulu, Usha; Tuncali, Kemal; Judy, Philip Frank; Shyn, Paul; Silverman, Stuart

    Purpose: To estimate effective dose during CT-guided cryoablation of liver tumors, and to assess which procedural factors contribute most to dose. Materials and methods: Our institutional review board approved this retrospective, HIPAA-compliant study. A total of 20 CT-guided percutaneous liver tumor cryoablation procedures were performed in 18 patients. Effective dose was determined by multiplying the dose length product for each CT scan obtained during the procedure by a conversion factor (0.015 mSv/mGy-cm), and calculating the sum for each phase of the procedure: planning, targeting, monitoring, and post-ablation survey. Effective dose of each phase was compared using a repeated measures analysis. Using Spearman correlation coefficients, effective doses were correlated with procedural factors including number of scans, ratio of targeting distance to tumor size, anesthesia type, number of applicators, performance of ancillary procedures (hydrodissection and biopsy), and use of CT fluoroscopy. Results: Effective dose per procedure was 72 ± 18 mSv. The effective dose of targeting (37.5 ± 12.5 mSv) was the largest component compared to the effective dose of the planning phase (4.8 ± 2.2 mSv), the monitoring phase (25.5 ± 6.8 mSv), and the post-ablation survey (4.1 ± 1.9 mSv) phase (p < 0.05). Effective dose correlated positively only with the number of scans (p < 0.01). Conclusions: The effective dose of CT-guided percutaneous cryoablation of liver tumors can be substantial. Reducing the number of scans during the procedure is likely to have the greatest effect on lowering dose.