Person: Mahmood, Feroze-Ud-Den
Email Address
AA Acceptance Date
Birth Date
Research Projects
Organizational Units
Job Title
Last Name
First Name
Name
Search Results
Publication Subclinical Left Ventricular Dysfunction in Preeclamptic Women With Preserved Left Ventricular Ejection Fraction
(Ovid Technologies (Wolters Kluwer Health), 2012-11) Shahul, Sajid; Rhee, Julie; Gulati, Gaurav; Hess, Philip; Mahmood, Feroze-Ud-Den; Arany, Zolt; Rana, Sarosh; Talmor, Daniel; Hacker, Michele; Mitchell, JohnBackground-Patients with preeclampsia are at risk for cardiovascular disease. Changes in cardiac function are subtle in preeclampsia and are difficult to quantify with conventional imaging. Strain measurements using speckle-tracking echocardiography have been used to sensitively quantify abnormalities in other disease settings.Methods and Results-We evaluated the feasibility and sensitivity of strain imaging using speckle-tracking echocardiography in women with preeclampsia. Forty-seven women were enrolled in this pilot study and 39 were analyzed: 11 with preeclampsia, 17 without a hypertensive disorder, and 11 with nonproteinuric hypertension. Echocardiographic ejection fraction and global peak longitudinal, radial, and circumferential strain were measured. Longitudinal strain was significantly worsened in women with preeclampsia compared with women without a hypertensive disorder (P=0.0001). Similar results were observed for radial strain (P=0.006) and circumferential strain (P=0.03). Women with preeclampsia also had significantly worsened longitudinal (P=0.04), radial (P=0.01), and circumferential (P=0.002) strain compared with women with nonproteinuric hypertension. Women with preeclampsia did not have a significantly different ejection fraction compared with women without a hypertensive disorder (P=0.16) and women with nonproteinuric hypertension (P=0.44).Conclusions-Myocardial strain imaging using speckle tracking is more sensitive than left ventricular ejection fraction to detect differences in left ventricular systolic function in women with and without preeclampsia.
Publication Imaging Skills for Transthoracic Echocardiography in Cardiology Fellows: The Value of Motion Metrics
(Medknow, 2016) Montealegre-Gallegos, Mario; Mahmood, Feroze-Ud-Den; Kim, Han; Bergman, Remco; Mitchell, John; Bose, Ruma; Hawthorne, Katie M.; O'Halloran, Thomas; Wong, Vanessa; Hess, Philip; Matyal, RobinaBackground: Proficiency in transthoracic echocardiography (TTE) requires an integration of cognitive knowledge and psychomotor skills. Whereas cognitive knowledge can be quantified, psychomotor skills are implied after repetitive task performance. We applied motion analyses to evaluate psychomotor skill acquisition during simulator-based TTE training.
Methods and Results: During the first month of their fellowship training, 16 cardiology fellows underwent a multimodal TTE training program for 4 weeks (8 sessions). The program consisted of online and live didactics as well as simulator training. Kinematic metrics (path length, time, probe accelerations) were obtained at the start and end of the course for 8 standard TTE views using a simulator. At the end of the course TTE image acquisition skills were tested on human models. After completion of the training program the trainees reported improved self-perceived comfort with TTE imaging. There was also an increase of 8.7% in post-test knowledge scores. There was a reduction in the number of probe accelerations [median decrease 49.5, 95% CI = 29-73, adjusted P < 0.01], total time [median decrease 10.6 s, 95% CI = 6.6-15.5, adjusted P < 0.01] and path length [median decrease 8.8 cm, 95% CI = 2.2-17.7, adjusted P < 0.01] from the start to the end of the course. During evaluation on human models, the trainees were able to obtain all the required TTE views without instructor assistance.
Conclusion: Simulator-derived motion analyses can be used to objectively quantify acquisition of psychomotor skills during TTE training. Such an approach could be used to assess readiness for clinical practice of TTE.