Person:

Matias, Wilfredo

Loading...
Profile Picture

Email Address

AA Acceptance Date

Birth Date

Research Projects

Organizational Units

Job Title

Last Name

Matias

First Name

Wilfredo

Name

Matias, Wilfredo

Search Results

Now showing 1 - 2 of 2
  • Publication

    Antibody Secreting Cell Responses following Vaccination with Bivalent Oral Cholera Vaccine among Haitian Adults

    (Public Library of Science, 2016) Matias, Wilfredo; Falkard, Brie; Charles, Richelle; Mayo-Smith, Leslie M.; Teng, Jessica E.; Xu, Peng; Kováč, Pavol; Ryan, Edward; Qadri, Firdausi; Franke, Molly; Ivers, Louise C.; Harris, Jason

    Background: The bivalent whole-cell (BivWC) oral cholera vaccine (Shanchol) is effective in preventing cholera. However, evaluations of immune responses following vaccination with BivWC have been limited. To determine whether BivWC induces significant mucosal immune responses, we measured V. cholerae O1 antigen-specific antibody secreting cell (ASC) responses following vaccination. Methodology/Principal Findings We enrolled 24 Haitian adults in this study, and administered doses of oral BivWC vaccine 14 days apart (day 0 and day 14). We drew blood at baseline, and 7 days following each vaccine dose (day 7 and 21). Peripheral blood mononuclear cells (PBMCs) were isolated, and ASCs were enumerated using an ELISPOT assay. Significant increases in Ogawa (6.9 cells per million PBMCs) and Inaba (9.5 cells per million PBMCs) OSP-specific IgA ASCs were detected 7 days following the first dose (P < 0.001), but not the second dose. The magnitude of V. cholerae-specific ASC responses did not appear to be associated with recent exposure to cholera. ASC responses measured against the whole lipolysaccharide (LPS) antigen and the OSP moiety of LPS were equivalent, suggesting that all or nearly all of the LPS response targets the OSP moiety. Conclusions/Significance: Immunization with the BivWC oral cholera vaccine induced ASC responses among a cohort of healthy adults in Haiti after a single dose. The second dose of vaccine resulted in minimal ASC responses over baseline, suggesting that the current dosing schedule may not be optimal for boosting mucosal immune responses to V. cholerae antigens for adults in a cholera-endemic area.

  • Publication

    Laboratory evaluation of immunochromatographic rapid diagnostic tests for cholera in Haiti

    (Public Library of Science, 2017) Matias, Wilfredo; Julceus, Fabrice E.; Abelard, Cademil; Mayo-Smith, Leslie M.; Franke, Molly; Harris, Jason; Ivers, Louise C.

    Background: Rapid diagnostic tests (RDT) for cholera are promising tools for detecting cholera in areas with limited laboratory infrastructure. However, evidence on the characteristics of the many available RDTs is scarce, and their use has been limited by suboptimal performance. We evaluated the performance characteristics of three cholera RDTs from Span Diagnostics, Artron Laboratories, and Standard Diagnostics in a regional laboratory in Haiti. Methodology/Principal findings We retrospectively reviewed records from May 2014 to October 2015 of a laboratory-based surveillance program for Vibrio cholerae at Hôpital Saint-Nicolas in Saint-Marc, Haiti. We compared the results of 511 Crystal VC, 129 Artron and 451 SD Bioline RDTs to bacterial culture as the gold standard. Of 905 cultures, 477 (52.7%) were positive for V. cholerae O1, of which 27.7% were serotype Inaba. No cultures grew V. cholerae O139. Sensitivity and specificity of Crystal VC were 98.6% (95%CI: 96.5%-99.6%) and 71.1% (95%CI: 64.7%-76.9%), respectively. Artron demonstrated a sensitivity of 98.6% (95%CI: 92.7%-100%) and specificity of 69.1% (95%CI: 55.2%-80.9%). SD Bioline demonstrated a sensitivity of 81.1% (95%CI: 75.6%-85.8%) and specificity of 92.8% (95%CI: 88.4%-95.9%). Crystal VC and Artron frequently showed false positive O139 bands, whereas none were seen with SD Bioline. Conclusions/Significance: There is significant variation in the performance of different cholera diagnostic RDTs. Artron and Crystal VC RDTs have high sensitivity and low specificity, while SD Bioline RDT has low to moderate sensitivity and high specificity when performed by laboratory technicians in Haiti. Study limitations included its retrospective design. The suboptimal characteristics of these tests limit their use as clinical point-of-care tests; however, they may be useful in outbreak response, surveillance, and research in resource-limited settings.