Person:

Picard, Michael

Loading...
Profile Picture

Email Address

AA Acceptance Date

Birth Date

Research Projects

Organizational Units

Job Title

Last Name

Picard

First Name

Michael

Name

Picard, Michael

Search Results

Now showing 1 - 10 of 13
  • Publication

    Assessment of Echocardiography and Biomarkers for the Extended Prediction of Cardiotoxicity in Patients Treated With Anthracyclines, Taxanes, and Trastuzumab

    (Ovid Technologies (Wolters Kluwer Health), 2012) Sawaya, H.; Sebag, I. A.; Plana, J. C.; Januzzi, James; Ky, B.; Tan, T. C.; Cohen, V.; Banchs, J.; Carver, J. R.; Wiegers, S. E.; Martin, R. P.; Picard, Michael; Gerszten, Robert; Halpern, Elkan F.; Passeri, Jonathan; Kuter, Irene; Scherrer-Crosbie, Marielle

    Background: Because cancer patients survive longer, the impact of cardiotoxicity associated with the use of cancer treatments escalates. The present study investigates whether early alterations of myocardial strain and blood biomarkers predict incident cardiotoxicity in patients with breast cancer during treatment with anthracyclines, taxanes, and trastuzumab. Methods and Results: Eighty-one women with newly diagnosed human epidermal growth factor receptor 2–positive breast cancer, treated with anthracyclines followed by taxanes and trastuzumab were enrolled to be evaluated every 3 months during their cancer therapy (total of 15 months) using echocardiograms and blood samples. Left ventricular ejection fraction, peak systolic longitudinal, radial, and circumferential myocardial strain were calculated. Ultrasensitive troponin I, N-terminal pro–B-type natriuretic peptide, and the interleukin family member (ST2) were also measured. Left ventricular ejection fraction decreased (64 ± 5% to 59 ± 6%; P<0.0001) over 15 months. Twenty-six patients (32%, [22%–43%]) developed cardiotoxicity as defined by the Cardiac Review and Evaluation Committee Reviewing Trastuzumab; of these patients, 5 (6%, [2%–14%]) had symptoms of heart failure. Peak systolic longitudinal myocardial strain and ultrasensitive troponin I measured at the completion of anthracyclines treatment predicted the subsequent development of cardiotoxicity; no significant associations were observed for left ventricular ejection fraction, N-terminal pro–B-type natriuretic peptide, and ST2. Longitudinal strain was <19% in all patients who later developed heart failure. Conclusions: In patients with breast cancer treated with anthracyclines, taxanes, and trastuzumab, systolic longitudinal myocardial strain and ultrasensitive troponin I measured at the completion of anthracyclines therapy are useful in the prediction of subsequent cardiotoxicity and may help guide treatment to avoid cardiac side-effects.

  • Publication

    Validation of Noninvasive Measurements of Cardiac Output in Mice Using Echocardiography

    (Elsevier BV, 2011) Tournoux, François; Petersen, Bodil; Thibault, Hélène; Zou, Lin; Raher, Michael J.; Kurtz, Baptiste; Halpern, Elkan F.; Chaput, Miguel; Chao, Wei; Picard, Michael; Scherrer-Crosbie, Marielle

    Although multiple echocardiographic methods exist to calculate cardiac output (CO), they have not been validated in mice using a reference method. Echocardiographic and flow probe measurements of CO were obtained in mice before and after albumin infusion and inferior vena cava occlusions. Echocardiography was also performed before and after endotoxin injection. Cardiac output was calculated using LV volumes obtained from a M Mode or a 2D view, LV stroke volume calculated using the pulmonary flow, or estimated using pulmonary VTI. Close correlations were demonstrated between flow probe-measured CO and all echocardiographic measurements of CO. All echocardiographic-derived CO overestimated the flow-probe measured CO. 2D images-derived CO was associated with the smallest overestimation of CO. Interobserver variability was lowest for pulmonary VTI derived CO. In mice, CO calculated from 2D parasternal long axis images is most accurate when compared to flow probe measurements, however, pulmonary VTI-derived CO is subject to less variability.

  • Publication

    In Vivo Noninvasive Characterization of Brown Adipose Tissue Blood Flow by Contrast Ultrasound in Mice

    (Ovid Technologies (Wolters Kluwer Health), 2012) Baron, David M.; Clerte, Maeva; Brouckaert, Peter; Raher, Michael J.; Flynn, Aidan W.; Zhang, Haihua; Carter, Edward; Picard, Michael; Bloch, Kenneth; Buys, Emmanuel; Scherrer-Crosbie, Marielle

    Background—Interventions to increase brown adipose tissue (BAT) volume and activation are being extensively investigated as therapies to decrease the body weight in obese subjects. Noninvasive methods to monitor these therapies in animal models and humans are rare. We investigated whether contrast ultrasound (CU) performed in mice could detect BAT and measure its activation by monitoring BAT blood flow. After validation, CU was used to study the role of uncoupling protein 1 and nitric oxide synthases in the acute regulation of BAT blood flow. Methods and Results—Blood flow of interscapular BAT was assessed in mice (n=64) with CU by measuring the signal intensity of continuously infused contrast microbubbles. Blood flow of BAT estimated by CU was 0.5±0.1 (mean±SEM) dB/s at baseline and increased 15-fold during BAT stimulation by norepinephrine (1 µg·kg−1·min−1). Assessment of BAT blood flow using CU was correlated to that performed with fluorescent microspheres (R2=0.86, P<0.001). To evaluate whether intact BAT activation is required to increase BAT blood flow, CU was performed in uncoupling protein 1–deficient mice with impaired BAT activation. Norepinephrine infusion induced a smaller increase in BAT blood flow in uncoupling protein 1–deficient mice than in wild-type mice. Finally, we investigated whether nitric oxide synthases played a role in acute norepinephrine-induced changes of BAT blood flow. Genetic and pharmacologic inhibition of nitric oxide synthase 3 attenuated the norepinephrine-induced increase in BAT blood flow. Conclusions—These results indicate that CU can detect BAT in mice and estimate BAT blood flow in mice with functional differences in BAT.

  • Publication

    Longitudinal Changes in Multiple Biomarkers Are Associated with Cardiotoxicity in Breast Cancer Patients Treated with Doxorubicin, Taxanes, and Trastuzumab

    (American Association for Clinical Chemistry (AACC), 2015) Putt, M.; Hahn, V. S.; Januzzi, James; Sawaya, H.; Sebag, I. A.; Plana, J. C.; Picard, Michael; Carver, J. R.; Halpern, Elkan F.; Kuter, Irene; Passeri, Jonathan; Cohen, V.; Banchs, J.; Martin, R. P.; Gerszten, Robert; Scherrer-Crosbie, Marielle; Ky, B.

    BACKGROUND: Biomarkers may play an important role in identifying patients at risk for cancer therapy cardiotoxicity. Our objectives were to define the patterns of change in biomarkers with cancer therapy and their associations with cardiotoxicity. METHODS: In a multicenter cohort of 78 breast cancer patients undergoing doxorubicin and trastuzumab therapy, 8 biomarkers were evaluated at baseline and every 3 months over a maximum follow-up of 15 months. These biomarkers, hypothesized to be mechanistically relevant to cardiotoxicity, included high-sensitivity cardiac troponin I (hs-cTnI), high-sensitivity C-reactive protein (hsCRP), N-terminal pro–B-type natriuretic peptide (NT-proBNP), growth differentiation factor 15 (GDF-15), myeloperoxidase (MPO), placental growth factor (PlGF), soluble fms-like tyrosine kinase receptor-1 (sFlt-1), and galectin 3 (gal-3). We determined if biomarker increases were associated with cardiotoxicity at the same visit and the subsequent visit over the entire course of therapy. Cardiotoxicity was defined by the Cardiac Review and Evaluation Criteria; alternative definitions were also considered. RESULTS: Across the entire cohort, all biomarkers except NT-proBNP and gal-3 demonstrated increases by 3 months; these increases persisted for GDF-15, PlGF, and hs-cTnI at 15 months. Increases in MPO, PlGF, and GDF-15 were associated with cardiotoxicity at the same visit [MPO hazard ratio 1.38 (95% CI 1.10–1.71), P = 0.02; PlGF 3.78 (1.30–11.0), P = 0.047; GDF-15 1.71 (1.15–2.55), P = 0.01] and the subsequent visit. MPO was robust to alternative outcome definitions. CONCLUSIONS: Increases in MPO are associated with cardiotoxicity over the entire course of doxorubicin and trastuzumab therapy. Assessment with PlGF and GDF-15 may also be of value. These findings motivate validation studies in additional cohorts.

  • Publication

    Lessons learned from MPI and physiologic testing in randomized trials of stable ischemic heart disease: COURAGE, BARI 2D, FAME, and ISCHEMIA

    (Springer Science + Business Media, 2013) Phillips, Lawrence M.; Hachamovitch, Rory; Berman, Daniel S.; Iskandrian, Ami E.; Min, James K.; Picard, Michael; Kwong, Raymond; Friedrich, Matthias G.; Scherrer-Crosbie, Marielle; Hayes, Sean W.; Sharir, Tali; Gosselin, Gilbert; Mazzanti, Marco; Senior, Roxy; Beanlands, Rob; Smanio, Paola; Goyal, Abhi; Al-Mallah, Mouaz; Reynolds, Harmony; Stone, Gregg W.; Maron, David J.; Shaw, Leslee J.

    There is a preponderance of evidence that, in the setting of an acute coronary syndrome, an invasive approach using coronary revascularization has a morbidity and mortality benefit. However, recent stable ischemic heart disease (SIHD) randomized clinical trials testing whether the addition of coronary revascularization to guideline-directed medical therapy (GDMT) reduces death or major cardiovascular events have been negative. Based on the evidence from these trials, the primary role of GDMT as a front line medical management approach has been clearly defined in the recent SIHD clinical practice guideline; the role of prompt revascularization is less precisely defined. Based on data from observational studies, it has been hypothesized that there is a level of ischemia above which a revascularization strategy might result in benefit regarding cardiovascular events. However, eligibility for recent negative trials in SIHD has mandated at most minimal standards for ischemia. An ongoing randomized trial evaluating the effectiveness of randomization of patients to coronary angiography and revascularization as compared to no coronary angiography and GDMT in patients with moderate-severe ischemia will formally test this hypothesis. The current review will highlight the available evidence including a review of the published and ongoing SIHD trials.

  • Publication

    Early Increases in Multiple Biomarkers Predict Subsequent Cardiotoxicity in Patients With Breast Cancer Treated With Doxorubicin, Taxanes, and Trastuzumab

    (Elsevier BV, 2014) Ky, Bonnie; Putt, Mary; Sawaya, Heloisa; French, Benjamin; Januzzi, James; Sebag, Igal A.; Plana, Juan Carlos; Cohen, Victor; Banchs, Jose; Carver, Joseph R.; Wiegers, Susan E.; Martin, Randolph P.; Picard, Michael; Gerszten, Robert; Halpern, Elkan F.; Passeri, Jonathan; Kuter, Irene; Scherrer-Crosbie, Marielle

    Objectives: The aim of this study was to determine if individual or multiple biomarkers are associated with cardiotoxicity in patients with breast cancer undergoing cancer therapy. Background: Current methods to identify patients at risk for cardiotoxicity from cancer therapy are inadequate. Methods: We measured 8 biomarkers in a multicenter cohort of 78 patients with breast cancer undergoing doxorubicin and trastuzumab therapy: ultrasensitive troponin I (TnI), high-sensitivity C-reactive protein (CRP), N-terminal pro–B-type natriuretic peptide (NT-proBNP), growth differentiation factor (GDF)-15, myeloperoxidase (MPO), placental growth factor (PlGF), soluble fms-like tyrosine kinase receptor (sFlt)-1, and galectin (gal)-3. Cardiotoxicity, defined by the Cardiac Review and Evaluation Committee criteria, was assessed every 3 months for up to 15 months. Hazard ratios (HRs) of cardiotoxicity risk were assessed for each biomarker at baseline, at visit 2 (3 months), and as a function of the difference between visit 2 and baseline. Joint models were assessed for the most promising biomarkers. Results: TnI, CRP, GDF-15, MPO, PlGF, and sFlt-1 levels increased from baseline to visit 2 (p < 0.05). A greater risk of cardiotoxicity was associated with interval changes in TnI (HR: 1.38 per SD; 95% confidence interval: 1.05 to 1.81; p = 0.02) and MPO (HR: 1.34 per SD; 95% confidence interval: 1.00 to 1.80; p = 0.048) and in models combining both markers (p = 0.007 and p = 0.03, respectively). The risk of cardiotoxicity was 46.5% in patients with the largest changes in both markers (ΔTnI >121.8 μg/l; ΔMPO >422.6 pmol/l). Conclusions: Early increases in TnI and MPO levels offer additive information about the risk of cardiotoxicity in patients undergoing doxorubicin and trastuzumab therapy. Independent validation of these findings is necessary before application to clinical practice.

  • Publication

    Preload Dependency of Left Ventricular Torsion: The Impact of Normal Saline Infusion

    (Ovid Technologies (Wolters Kluwer Health), 2010) Weiner, Rory; Weyman, Arthur; Khan, A. M.; Reingold, J. S.; Chen-Tournoux, A. A.; Scherrer-Crosbie, Marielle; Picard, Michael; Wang, T. J.; Baggish, Aaron

    Background: Left ventricular (LV) rotation results from contraction of obliquely oriented myocardial fibers. The net difference between systolic apical counterclockwise rotation and basal clockwise rotation is left ventricular torsion (LVT). Although LVT is altered in various cardiac diseases, determinants of LVT are incompletely understood. Methods and Results: LV end-diastolic volume (LVEDV), LV apical and basal rotation, peak systolic LVT, and peak early diastolic untwisting rate (UTR) were measured by speckle tracking echocardiography in healthy subjects (n=8) before and after infusion of a weight-based normal saline bolus (2.1±0.3 L). Saline infusion lead to a significant increase in end-diastolic LV internal diameter (45.9±3.7 versus 47.6±4.2 mm; p=0.002) and LVEDV (90.0±21.6 versus 98.3±19.6 mL; p=0.01). Stroke volume (51.3±10.9 versus 63.0±15.5 mL; p = 0.003) and cardiac output (3.4±0.8 versus 4.4±1.5 L/min; p = 0.007) increased while there was no change in heart rate and blood pressure. There was a significant increase in the magnitude of peak systolic apical rotation (7.5±2.4 versus 10.5±2.8 degrees; p < 0.001) but no change in basal rotation (-4.1±2.3 versus -4.8±3.1 degrees; p = 0.44). Accordingly, peak systolic LVT increased by 33% following saline infusion (11.2±1.3 versus 14.9±1.7 degrees; p < 0.001). This saline-induced increase in LVT was associated with a marked increase in peak early diastolic UTR (72.3±21.4 versus 136.8±30.0 degrees/s; p < 0.001). Conclusions: Peak systolic LVT and peak early diastolic UTR are preload dependent. Changes in LV preload should be considered when interpreting results of future LVT studies.

  • Publication

    Comparative Definitions for Moderate-Severe Ischemia in Stress Nuclear, Echocardiography, and Magnetic Resonance Imaging

    (Elsevier BV, 2014) Shaw, Leslee J.; Berman, Daniel S.; Picard, Michael; Friedrich, Matthias G.; Kwong, Raymond; Stone, Gregg W.; Senior, Roxy; Min, James K.; Hachamovitch, Rory; Scherrer-Crosbie, Marielle; Mieres, Jennifer H.; Marwick, Thomas H.; Phillips, Lawrence M.; Chaudhry, Farooq A.; Pellikka, Patricia A.; Slomka, Piotr; Arai, Andrew E.; Iskandrian, Ami E.; Bateman, Timothy M.; Heller, Gary V.; Miller, Todd D.; Nagel, Eike; Goyal, Abhinav; Borges-Neto, Salvador; Boden, William E.; Reynolds, Harmony R.; Hochman, Judith S.; Maron, David J.; Douglas, Pamela S.

    The lack of standardized reporting of the magnitude of ischemia on noninvasive imaging contributes to variability in translating the severity of ischemia across stress imaging modalities. We identified the risk of coronary artery disease (CAD) death or myocardial infarction (MI) associated with ≥10% ischemic myocardium on stress nuclear imaging as the risk threshold for stress echocardiography and cardiac magnetic resonance. A narrative review revealed that ≥10% ischemic myocardium on stress nuclear imaging was associated with a median rate of CAD death or MI of 4.9%/year (interquartile range: 3.75% to 5.3%). For stress echocardiography, ≥3 newly dysfunctional segments portend a median rate of CAD death or MI of 4.5%/year (interquartile range: 3.8% to 5.9%). Although imprecisely delineated, moderate-severe ischemia on cardiac magnetic resonance may be indicated by ≥4 of 32 stress perfusion defects or ≥3 dobutamine-induced dysfunctional segments. Risk-based thresholds can define equivalent amounts of ischemia across the stress imaging modalities, which will help to translate a common understanding of patient risk on which to guide subsequent management decisions.

  • Publication

    The value of core lab stress echocardiography interpretations: observations from the ISCHEMIA Trial

    (BioMed Central, 2015) Kataoka, Akihisa; Scherrer-Crosbie, Marielle; Senior, Roxy; Gosselin, Gilbert; Phaneuf, Denis; Guzman, Gabriela; Perna, Gian; Lara, Alfonso; Kedev, Sasko; Mortara, Andrea; El-Hajjar, Mohammad; Shaw, Leslee J.; Reynolds, Harmony R.; Picard, Michael

    Background: Stress echocardiography (SE) is dependent on subjective interpretations. As a prelude to the International Study of Comparative Health Effectiveness with Medical and Invasive Approaches (ISCHEMIA) Trial, potential sites were required to submit two SE, one with moderate or severe left ventricular (LV) myocardial ischemia and one with mild ischemia. We evaluated the concordance of site and core lab interpretations. Methods: Eighty-one SE were submitted from 41 international sites. Ischemia was classified by the number of new or worsening segmental LV wall motion abnormalities (WMA): none, mild (1 or 2) or moderate or severe (3 or more) by the sites and the core lab. Results: Core lab classified 6 SE as no ischemia, 35 mild and 40 moderate or greater. There was agreement between the site and core in 66 of 81 total cases (81 %, weighted kappa coefficient [K] =0.635). Agreement was similar for SE type - 24 of 30 exercise (80 %, K = 0.571) vs. 41 of 49 pharmacologic (84 %, K = 0.685). The agreement between poor or fair image quality (27 of 36 cases, 75 %, K = 0.492) was not as good as for the good or excellent image quality cases (39 of 45 cases, 87 %, K = 0.755). Differences in concordance were noted for degree of ischemia with the majority of discordant interpretations (87 %) occurring in patients with no or mild LV myocardial ischemia. Conclusions: While site SE interpretations are largely concordant with core lab interpretations, this appears dependent on image quality and the extent of WMA. Thus core lab interpretations remain important in clinical trials where consistency of interpretation across a range of cases is critical. Trial registration ClinicalTrials.gov NCT01471522

  • Publication

    Brown Adipose Tissue Blood Flow and Mass in Obesity: A Contrast Ultrasound Study in Mice

    (Elsevier BV, 2013) Clerte, Maëva; Baron, David; Brouckaert, Peter; Ernande, Laura; Raher, Michael J.; Flynn, Aidan W.; Picard, Michael; Bloch, Kenneth; Buys, Emmanuel; Scherrer-Crosbie, Marielle

    Background: When activated by the sympathetic nervous system, brown adipose tissue (BAT) increases energy expenditure to produce heat. Augmenting BAT mass or increasing BAT activation could potentially be used to decrease obesity. Noninvasive methods to detect and monitor BAT mass are needed. Contrast ultrasound can estimate BAT blood flow and is able to measure the perfused volume of an organ and thus its mass. The objective of this study was to evaluate whether contrast ultrasound could characterize BAT mass in two mouse models of obesity: wild-type mice fed a high-fat diet and mutant db/db mice. Methods: Contrast ultrasound of BAT (Definity 2 μL/min; 14-MHz linear probe) was performed before and after stimulation of BAT with norepinephrine (NE). BAT replenishment curves were obtained, and blood flow was estimated by the product of the curve’s plateau and slope. Additionally, consecutive two-dimensional images of perfused BAT were acquired at 1-mm intervals after stimulation with NE and used to assess BAT volume and mass. Results: BAT blood flow increased after NE infusion in all mice studied. Blood flow response to NE was similar in wild-type mice fed either a low-fat diet or a high-fat diet. BAT blood flow was lower in db/db mice than in wild-type mice (P = .02). Contrast ultrasound–derived BAT mass was correlated with BAT mass obtained at necropsy (R2 = 0.83, P < .001). BAT mass was higher in mice fed a high-fat diet than in those fed a low-fat diet. Conclusions: Contrast ultrasound can be used to estimate BAT mass in mice when BAT vascularization is not significantly impaired. This noninvasive technique may potentially allow the serial evaluation of therapies designed to augment BAT mass.