Person:
Rubash, Harry

Loading...
Profile Picture

Email Address

AA Acceptance Date

Birth Date

Research Projects

Organizational Units

Job Title

Last Name

Rubash

First Name

Harry

Name

Rubash, Harry

Search Results

Now showing 1 - 2 of 2
  • Thumbnail Image
    Publication
    Function of Anterior Talofibular and Calcaneofibular Ligaments During In-Vivo Motion of the Ankle Joint Complex
    (BioMed Central, 2009) de Asla, Richard J; Kozánek, Michal; Wan, Lu; Rubash, Harry; Li, Guoan
    Background: Despite the numerous in-vitro studies on the mechanical properties and simulated injury mechanisms of the anterior talofibular ligament (ATFL) and calcaneofibular ligament (CFL), the in-vivo biomechanical behavior of these two ligaments has not yet been described. Methods: Apparent length of the ATFL and CFL was measured in four ankles in healthy male subjects between 32 and 45 years of age (two left and two right) during a dorsiflexion-plantarflexion and supination-pronation arc of motion using a combined dual-orthogonal fluoroscopic and magnetic resonance imaging technique. Results: The ATFL elongated from the neutral position at 16.3 +/- 3.0 mm to 20.8 +/- 2.7 mm at maximal plantarflexion and shortened significantly from the neutral position to 13.9 +/- 2.9 mm at maximal dorsiflexion (p = 0.01). The CFL shortened from the neutral position at 28.0 +/- 2.9 mm to 26.6 +/- 2.2 mm at maximal plantarflexion (p = 0.08) and elongated significantly from the neutral position to 29.9 +/- 3.0 mm at maximal dorsiflexion (p = 0.003). The ATFL elongated significantly from 14.8 +/- 2.5 mm at maximal pronation to 17.4 +/- 3.0 mm at maximal supination (p = 0.08). At the same time, the CFL shortened from 31.0 +/- 3.8 mm at maximal pronation to 26.9 +/- 3.6 mm at maximal supination (p = 0.02). Conclusion: The results showed that the ATFL elongates more during plantarflexion and supination whereas the CFL increases in length with dorsiflexion and pronation. Concurrently, these data also demonstrated the reciprocal function between the two ligaments. While one shortens, the other one elongates. The different elongation of the ATFL and CFL during the same motion arc suggests that under excessive loading conditions the ATFL might be more vulnerable in plantarflexion and supination while the CFL might be more susceptible to injury in dorsiflexion and pronation. Furthermore, in the case of surgical reconstruction the grafts used to reconstruct the two ligaments may need to be tensioned at different positions of the ankle in order to reproduce their natural in vivo function.
  • Thumbnail Image
    Publication
    Ambulatory Measurement of Knee Motion and Physical Activity: Preliminary Evaluation of a Smart Activity Monitor
    (BioMed Central, 2006) Huddleston, James; Alaiti, Amer; Goldvasser, Dov; Scarborough, Donna; Freiberg, Andrew; Rubash, Harry; Malchau, Henrik; Harris, William; Krebs, David
    Background: There is currently a paucity of devices available for continuous, long-term monitoring of human joint motion. Non-invasive, inexpensive devices capable of recording human activity and joint motion have many applications for medical research. Such a device could be used to quantify range of motion outside the gait laboratory. The purpose of this study was to test the accuracy of the modified Intelligent Device for Energy Expenditure and Activity (IDEEA) in measuring knee flexion angles, to detect different physical activities, and to quantify how often healthy subjects use deep knee flexion in the ambulatory setting. Methods: We compared Biomotion Laboratory (BML) "gold standard" data to simultaneous IDEEA measures of knee motion and gait, step up/down, and stair descent in 5 healthy subjects. In addition, we used a series of choreographed physical activities outside the BML to confirm the IDEEA's ability to accurately measure 7 commonly-performed physical activities. Subjects then continued data collection during ordinary activities outside the gait laboratory. Results: Pooled correlations between the BML and IDEEA knee flexion angles were .97 +/- .03 for step up/down, .98 +/- .02 for stair descent, and .98 +/- .01 for gait. In the BML protocol, the IDEEA accurately identified gait, but was less accurate in identifying step up/down and stair descent. During sampling outside the BML, the IDEEA accurately detected walking, running, stair ascent, stair descent, standing, lying, and sitting. On average, subjects flexed their knees >120° for 0.17% of their data collection periods outside the BML. Conclusion: The modified IDEEA system is a useful clinical tool for evaluating knee motion and multiple physical activities in the ambulatory setting. These five healthy subjects rarely flexed their knees >120°.