Person:

Fell, Eric

Loading...
Profile Picture

Email Address

AA Acceptance Date

Birth Date

Research Projects

Organizational Units

Job Title

Last Name

Fell

First Name

Eric

Name

Fell, Eric

Search Results

Now showing 1 - 3 of 3
  • Publication

    Near Neutral pH Redox Flow Battery with Low Permeability and Long‐Lifetime Phosphonated Viologen Active Species

    (Wiley, 2020-04-06) Jin, Shijian; Fell, Eric; Vina-Lopez, Lucia; Jing, Yan; Michalak, Winston; Gordon, Roy; Aziz, Michael

    A highly stable phosphonate‐functionalized viologen is introduced as the redox‐active material in a negative potential electrolyte for aqueous redox flow batteries (ARFBs) operating at nearly neutral pH. The solubility is 1.23 m and the reduction potential is the lowest of any substituted viologen utilized in a flow battery, reaching −0.462 V versus SHE at pH = 9. The negative charges in both the oxidized and the reduced states of 1,1′‐bis(3‐phosphonopropyl)‐[4,4′‐bipyridine]‐1,1′‐diium dibromide (BPP−Vi) effect low permeability in cation exchange membranes and suppress a bimolecular mechanism of viologen decomposition. A flow battery pairing BPP−Vi with a ferrocyanide‐based positive potential electrolyte across an inexpensive, non‐fluorinated cation exchange membrane at pH = 9 exhibits an open‐circuit voltage of 0.9 V and a capacity fade rate of 0.016% per day or 0.00069% per cycle. Overcharging leads to viologen decomposition, causing irreversible capacity fade. This work introduces extremely stable, extremely low‐permeating and low reduction potential redox active materials into near neutral ARFBs.

  • Publication

    The Poor Academic’s DC-Offset for Reversing Polarity in Electrochemical Cells: Application to Redox Flow Cells

    (The Electrochemical Society, 2022-09-01) Amini, Kiana; Fell, Eric; Aziz, Michael

    We provide a simple and inexpensive manual DC-offset method for extending the accepted voltage range of a battery cycler to negative voltages, without interfering with the actual operation of the electrochemical cell under the test or exceeding the voltage specs of the battery cycler instrument. We describe the working principles of the method and validate the proposed setup by operating short-term and long-term redox flow battery cycling using compositionally symmetric cell, with open-circuit voltage of zero, and full cell configurations. The method can be used to extend the capability of battery cycler instrumentation to operate any electrochemical cell that requires the polarity to be reversed during operation. Applications include cycling of other symmetric cells (e.g., Li-ion cells), implementation of polarity reversal steps for rejuvenation of electroactive species or rebalancing electrochemical cells, and alternating polarity for electrochemical synthesis.

  • Publication

    A High Voltage Aqueous Zinc–Organic Hybrid Flow Battery

    (Wiley, 2019-05-17) Park, Minjoon; Beh, Eugene S.; Fell, Eric; Jing, Yan; Kerr, Emily; De Porcellinis, Diana; Goulet, Marc‐Antoni; Ryu, Jaechan; Wong, Andrew A.; Gordon, Roy; Cho, Jaephil; Aziz, Michael

    Water‐soluble redox‐active organic molecules have attracted extensive attention as electrical energy storage alternatives to redox‐active metals that are low in abundance and high in cost. Here an aqueous zinc–organic hybrid redox flow battery (RFB) is reported with a positive electrolyte comprising a functionalized 1,4‐hydroquinone bearing four (dimethylamino)methyl groups dissolved in sulfuric acid. By utilizing a three‐electrolyte, two‐membrane configuration this acidic positive electrolyte is effectively paired with an alkaline negative electrolyte comprising a Zn/[Zn(OH)4]2− redox couple and a hybrid RFB is operated at a high operating voltage of 2.0 V. It is shown that the electrochemical reversibility and kinetics of the organic redox species can be enhanced by an electrocatalyst, leading to a cyclic voltammetry peak separation as low as 35 mV and enabling an enhanced rate capability.