  • Publication

    Density-based separation in multiphase systems provides a simple method to identify sickle cell disease

    (Proceedings of the National Academy of Sciences, 2014) Kumar, A. A.; Patton, Matthew Reiser; Hennek, J. W.; Lee, S. Y. R.; D, G.; Yang, X.; Kanter, J.; Shevkoplyas, S. S.; Brugnara, Carlo; Whitesides, George

    Although effective low-cost interventions exist, child mortality attributable to sickle cell disease (SCD) remains high in low-resource areas due, in large part, to the lack of accessible diagnostic methods. The presence of dense (ρ > 1.120 g/cm3) cells is characteristic of SCD. The fluid, self-assembling step-gradients in density created by aqueous multiphase systems (AMPSs) identifies SCD by detecting dense cells. AMPSs separate different forms of red blood cells by density in a microhematocrit centrifuge and provide a visual means to distinguish individuals with SCD from those with normal hemoglobin or with nondisease, sickle-cell trait in under 12 min. Visual evaluation of a simple two-phase system identified the two main subclasses of SCD [homozygous (Hb SS) and heterozygous (Hb SC)] with a sensitivity of 90% (73–98%) and a specificity of 97% (86–100%). A three-phase system identified these two types of SCD with a sensitivity of 91% (78–98%) and a specificity of 88% (74–98%). This system could also distinguish between Hb SS and Hb SC. To the authors’ knowledge, this test demonstrates the first separation of cells by density with AMPSs, and the usefulness of AMPSs in point-of-care diagnostic hematology.

  • Publication

    Diagnosis of iron deficiency anemia using density-based fractionation of red blood cells

    (Royal Society of Chemistry (RSC), 2016) Hennek, Jonathan; Kumar, Ashok Ashwin; Wiltschko, Alexander Bame; Patton, Matthew Reiser; Lee, Si Yi Ryan; Brugnara, Carlo; Adams, Ryan Prescott; Whitesides, George

    Iron deficiency anemia (IDA) is a nutritional disorder that impacts over one billion people worldwide, it causes permanent cognitive impairment in children, fatigue in adults, and suboptimal outcomes in pregnancy. IDA can be diagnosed by detection of red blood cells (RBCs) that are characteristically small (microcytic) and deficient in hemoglobin (hypochromic), typically by examining the results of a complete blood count performed by a hematology analyzer. These instruments are expensive, not portable, and require trained personnel; they are therefore, unavailable in many low-resource settings. This paper describes a low-cost and rapid method to diagnose IDA using aqueous multiphase systems (AMPS)—thermodynamically stable mixtures of biocompatible polymers and salt that spontaneously form discrete layers having sharp steps in density. AMPS are preloaded into a microhematocrit tube and used with a drop of blood from a fingerstick. After only two minutes in a low-cost centrifuge, the tests (n = 152) were read by eye with a sensitivity of 84% (72-93%) and a specificity of 78% (68-86%), corresponding to an area under the curve (AUC) of 0.89. The AMPS test outperforms diagnosis by hemoglobin alone (AUC = 0.73) and is comparable to methods used in clinics like reticulocyte hemoglobin concentration (AUC = 0.91). Standard machine learning tools were used to analyze images of the resulting tests captured by a standard desktop scanner to 1) slightly improve diagnosis of IDA—sensitivity of 90% (83-96%) and a specificity of 77% (64-87%), and 2) predict several important red blood cell parameters, such as mean corpuscular hemoglobin concentration. These results suggest that the use of AMPS combined with machine learning provides an approach to developing point-of-care hematology.