Publication Deep Inspiration and the Emergence of Ventilation Defects during Bronchoconstriction: A Computational Study
(Public Library of Science, 2014) Golnabi, Amir H.; Harris, R. Scott; Venegas, Jose; Winkler, TiloDeep inspirations (DIs) have a dilatory effect on airway smooth muscle (ASM) that helps to prevent or reduce more severe bronchoconstriction in healthy individuals. However, this bronchodilation appears to fail in some asthmatic patients or under certain conditions, and the reason is unclear. Additionally, quantitative effects of the frequency and magnitude of DIs on bronchodilation are not well understood. In the present study, we used a computational model of bronchoconstriction to study the effects of DI volumes, time intervals between intermittent DIs, relative speed of ASM constriction, and ASM activation on bronchoconstriction and the emergence of ventilation defects (VDefs). Our results showed a synergistic effect between the volume of DIs and the time intervals between them on bronchoconstriction and VDefs. There was a domain of conditions with sufficiently large volumes of DIs and short time intervals between them to prevent VDefs. Among conditions without VDefs, larger volumes of DIs resulted in greater airway dilation. Similarly, the time interval between DIs, during which the activated ASM re-constricts, affected the amplitude of periodic changes in airway radii. Both the relative speed of ASM constriction and ASM activation affected what volume of DIs and what time interval between them could prevent the emergence of VDefs. In conclusion, quantitative characteristics of DIs, such as their volume and time interval between them, affect bronchoconstriction and may contribute to difficulties in asthma. Better understanding of the quantitative aspects of DIs may result in novel or improved therapeutic approaches.
Publication The effect of disease and respiration on airway shape in patients with moderate persistent asthma
(Public Library of Science, 2017) Montesantos, Spyridon; Katz, Ira; Venegas, Jose; Pichelin, Marine; Caillibotte, GeorgesComputational models of gas transport and aerosol deposition frequently utilize idealized models of bronchial tree structure, where airways are considered a network of bifurcating cylinders. However, changes in the shape of the lung during respiration affect the geometry of the airways, especially in disease conditions. In this study, the internal airway geometry was examined, concentrating on comparisons between mean lung volume (MLV) and total lung capacity (TLC). A set of High Resolution CT images were acquired during breath hold on a group of moderate persistent asthmatics at MLV and TLC after challenge with a broncho-constrictor (methacholine) and the airway trees were segmented and measured. The airway hydraulic diameter (Dh) was calculated through the use of average lumen area (Ai) and average internal perimeter (Pi) at both lung volumes and was found to be systematically higher at TLC by 13.5±9% on average, with the lower lobes displaying higher percent change in comparison to the lower lobes. The average internal diameter (Din) was evaluated to be 12.4±6.8% (MLV) and 10.8±6.3% (TLC) lower than the Dh, for all the examined bronchi, a result displaying statistical significance. Finally, the airway distensibility per bronchial segment and per generation was calculated to have an average value of 0.45±0.28, exhibiting high variability both between and within lung regions and generations. Mixed constriction/dilation patterns were recorded between the lung volumes, where a number of airways either failed to dilate or even constricted when observed at TLC. We conclude that the Dh is higher than Din, a fact that may have considerable effects on bronchial resistance or airway loss at proximal regions. Differences in caliber changes between lung regions are indicative of asthma-expression variability in the lung. However, airway distensibility at generation 3 seems to predict distensibility more distally.