Multicenter Evaluation of a Novel Surveillance Paradigm for Complications of Mechanical Ventilation

Loading...
Thumbnail Image

Date

2011

Journal Title

Journal ISSN

Volume Title

Publisher

Public Library of Science
The Harvard community has made this article openly available. Please share how this access benefits you.

Research Projects

Organizational Units

Journal Issue

Citation

Klompas, Michael, Yosef Khan, Kenneth Kleinman, R. Scott Evans, James F. Lloyd, Kurt Stevenson, Matthew Samore, Richard Platt, and for the CDC Prevention Epicenters Program. 2011. “Multicenter Evaluation of a Novel Surveillance Paradigm for Complications of Mechanical Ventilation.” Edited by Benjamin Cowling. PLoS ONE 6 (3): e18062. doi:10.1371/journal.pone.0018062.

Abstract

Background: Ventilator-associated pneumonia (VAP) surveillance is time consuming, subjective, inaccurate, and inconsistently predicts outcomes. Shifting surveillance from pneumonia in particular to complications in general might circumvent the VAP definition's subjectivity and inaccuracy, facilitate electronic assessment, make interfacility comparisons more meaningful, and encourage broader prevention strategies. We therefore evaluated a novel surveillance paradigm for ventilator-associated complications (VAC) defined by sustained increases in patients' ventilator settings after a period of stable or decreasing support. Methods: We assessed 600 mechanically ventilated medical and surgical patients from three hospitals. Each hospital contributed 100 randomly selected patients ventilated 2-7 days and 100 patients ventilated > 7 days. All patients were independently assessed for VAP and for VAC. We compared incidence-density, duration of mechanical ventilation, intensive care and hospital lengths of stay, hospital mortality, and time required for surveillance for VAP and for VAC. A subset of patients with VAP and VAC were independently reviewed by a physician to determine possible etiology. Results: Of 597 evaluable patients, 9.3% had VAP (8.8 per 1,000 ventilator days) and 23% had VAC (21.2 per 1,000 ventilator days). Compared to matched controls, both VAP and VAC prolonged days to extubation (5.8, 95% CI 4.2-8.0 and 6.0, 95% CI 5.1-7.1 respectively), days to intensive care discharge (5.7, 95% CI 4.2-7.7 and 5.0, 95% CI 4.1-5.9), and days to hospital discharge (4.7, 95% CI 2.6-7.5 and 3.0, 95% CI 2.1-4.0). VAC was associated with increased mortality (OR 2.0, 95% CI 1.3-3.2) but VAP was not (OR 1.1, 95% CI 0.5-2.4). VAC assessment was faster (mean 1.8 versus 39 minutes per patient). Both VAP and VAC events were predominantly attributable to pneumonia, pulmonary edema, ARDS, and atelectasis. Conclusions: Screening ventilator settings for VAC captures a similar set of complications to traditional VAP surveillance but is faster, more objective, and a superior predictor of outcomes.

Description

Other Available Sources

Research Data

Keywords

Terms of Use

This article is made available under the terms and conditions applicable to Other Posted Material (LAA), as set forth at Terms of Service

Endorsement

Review

Supplemented By

Related Stories