Publication: A Functional Difficulty and Functional Pain Instrument for Hip and Knee Osteoarthritis
Open/View Files
Date
2009
Published Version
Journal Title
Journal ISSN
Volume Title
Publisher
BioMed Central
The Harvard community has made this article openly available. Please share how this access benefits you.
Citation
Jette, Alan M., Christine M. McDonough, Pengsheng Ni, Stephen M. Haley, Ronald K. Hambleton, Sippy Olarsch, David J. Hunter, Young-jo Kim, and David T. Felson. 2009. A functional difficulty and functional pain instrument for hip and knee osteoarthritis. Arthritis Research & Therapy 11(4): R107.
Research Data
Abstract
Introduction: The objectives of this study were to develop a functional outcome instrument for hip and knee osteoarthritis research (OA-FUNCTION-CAT) using item response theory (IRT) and computer adaptive test (CAT) methods and to assess its psychometric performance compared to the current standard in the field. Methods: We conducted an extensive literature review, focus groups, and cognitive testing to guide the construction of an item bank consisting of 125 functional activities commonly affected by hip and knee osteoarthritis. We recruited a convenience sample of 328 adults with confirmed hip and/or knee osteoarthritis. Subjects reported their degree of functional difficulty and functional pain in performing each activity in the item bank and completed the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). Confirmatory factor analyses were conducted to assess scale uni-dimensionality, and IRT methods were used to calibrate the items and examine the fit of the data. We assessed the performance of OA-FUNCTION-CATs of different lengths relative to the full item bank and WOMAC using CAT simulation analyses. Results: Confirmatory factor analyses revealed distinct functional difficulty and functional pain domains. Descriptive statistics for scores from 5-, 10-, and 15-item CATs were similar to those for the full item bank. The 10-item OA-FUNCTION-CAT scales demonstrated a high degree of accuracy compared with the item bank (r = 0.96 and 0.89, respectively). Compared to the WOMAC, both scales covered a broader score range and demonstrated a higher degree of precision at the ceiling and reliability across the range of scores. Conclusions: The OA-FUNCTION-CAT provided superior reliability throughout the score range and improved breadth and precision at the ceiling compared with the WOMAC. Further research is needed to assess whether these improvements carry over into superior ability to measure change.
Description
Other Available Sources
Keywords
Terms of Use
This article is made available under the terms and conditions applicable to Other Posted Material (LAA), as set forth at Terms of Service