Publication: Using a Body-Fixed Sensor to Identify Subclinical Gait Difficulties in Older Adults with IADL Disability: Maximizing the Output of the Timed Up and Go
Open/View Files
Date
2013
Published Version
Journal Title
Journal ISSN
Volume Title
Publisher
Public Library of Science
The Harvard community has made this article openly available. Please share how this access benefits you.
Citation
Weiss, Aner, Anat Mirelman, Aron S. Buchman, David A. Bennett, and Jeffrey M. Hausdorff. 2013. “Using a Body-Fixed Sensor to Identify Subclinical Gait Difficulties in Older Adults with IADL Disability: Maximizing the Output of the Timed Up and Go.” PLoS ONE 8 (7): e68885. doi:10.1371/journal.pone.0068885. http://dx.doi.org/10.1371/journal.pone.0068885.
Research Data
Abstract
Objective: The identification and documentation of subclinical gait impairments in older adults may facilitate the appropriate use of interventions for preventing or delaying mobility disability. We tested whether measures derived from a single body-fixed sensor worn during traditional Timed Up and Go (TUG) testing could identify subclinical gait impairments in community dwelling older adults without mobility disability. Methods: We used data from 432 older adults without dementia (mean age 83.30±7.04 yrs, 76.62% female) participating in the Rush Memory and Aging Project. The traditional TUG was conducted while subjects wore a body-fixed sensor. We derived measures of overall TUG performance and different subtasks including transitions (sit-to-stand, stand-to-sit), walking, and turning. Multivariate analysis was used to compare persons with and without mobility disability and to compare individuals with and without Instrumental Activities of Daily Living disability (IADL-disability), all of whom did not have mobility disability. Results: As expected, individuals with mobility disability performed worse on all TUG subtasks (p<0.03), compared to those who had no mobility disability. Individuals without mobility disability but with IADL disability had difficulties with turns, had lower yaw amplitude (p<0.004) during turns, were slower (p<0.001), and had less consistent gait (p<0.02). Conclusions: A single body-worn sensor can be employed in the community-setting to complement conventional gait testing. It provides a wide range of quantitative gait measures that appear to help to identify subclinical gait impairments in older adults.
Description
Other Available Sources
Keywords
Biology, Biophysics, Biotechnology, Bioengineering, Biomedical Engineering, Medicine, Anatomy and Physiology, Musculoskeletal System, Biomechanics, Clinical Research Design, Cohort Studies, Diagnostic Medicine, Test Evaluation, Geriatrics, Neurology, Movement Disorders
Terms of Use