Publication:
Whole-Slide Imaging Digital Pathology as a Platform for Teleconsultation: A Pilot Study Using Paired Subspecialist Correlations

Thumbnail Image

Date

2009

Journal Title

Journal ISSN

Volume Title

Publisher

College of American Pathologists
The Harvard community has made this article openly available. Please share how this access benefits you.

Research Projects

Organizational Units

Journal Issue

Citation

Wilbur, David C., Kalil Madi, Robert B. Colvin, Lyn M. Duncan, William C. Faquin, Judith A. Ferry, Matthew P. Frosch, et al. 2009. Whole-slide imaging digital pathology as a platform for teleconsultation: A pilot study using paired subspecialist correlations. Archives of Pathology & Laboratory Medicine 133, no. 12: 1949-1953.

Research Data

Abstract

Context.—Whole-slide imaging technology offers promise for rapid, Internet-based telepathology consultations between institutions. Before implementation, technical issues, pathologist adaptability, and morphologic pitfalls must be well characterized. Objective.—To determine whether interpretation of whole-slide images differed from glass-slide interpretation in difficult surgical pathology cases. Design.—Diagnostically challenging pathology slides from a variety of anatomic sites from an outside laboratory were scanned into whole digital format. Digital and glass slides were independently diagnosed by 2 subspecialty pathologists. Reference, digital, and glass-slide interpretations were compared. Operator comments on technical issues were gathered. Results.—Fifty-three case pairs were analyzed. There was agreement among digital, glass, and reference diagnoses in 45 cases (85%) and between digital and glass diagnoses in 48 (91%) cases. There were 5 digital cases (9%) discordant with both reference and glass diagnoses. Further review of each of these cases indicated an incorrect digital whole-slide interpretation. Neoplastic cases showed better correlation (93%) than did cases of nonneoplastic disease (88%). Comments on discordant cases related to digital whole technology focused on issues such as fine resolution and navigating ability at high magnification. Conclusions.—Overall concordance between digital whole-slide and standard glass-slide interpretations was good at 91%. Adjustments in technology, case selection, and technology familiarization should improve performance, making digital whole-slide review feasible for broader telepathology subspecialty consultation applications.

Description

Other Available Sources

Keywords

Terms of Use

Metadata Only

Endorsement

Review

Supplemented By

Referenced By

Related Stories