Publication:

Influence of healthy candidate bias in assessing clinical effectiveness for implantable cardioverter-defibrillators: cohort study of older patients with heart failure

Loading...
Thumbnail Image

Date

2014

Published Version

Journal Title

Journal ISSN

Volume Title

Publisher

BMJ Publishing Group Ltd.
The Harvard community has made this article openly available. Please share how this access benefits you.

Research Projects

Organizational Units

Journal Issue

Citation

Setoguchi, Soko, Lynne Warner Stevenson, Garrick C Stewart, Deepak L Bhatt, Andrew E Epstein, Manisha Desai, Lauren A Williams, and Chih-Ying Chen. 2014. “Influence of healthy candidate bias in assessing clinical effectiveness for implantable cardioverter-defibrillators: cohort study of older patients with heart failure.” BMJ : British Medical Journal 348 (1): g2866. doi:10.1136/bmj.g2866. http://dx.doi.org/10.1136/bmj.g2866.

Abstract

Objective: To assess the potential contribution of unmeasured general health status to patient selection in assessments of the clinical effectiveness of implantable cardioverter-defibrillator (ICD) therapy. Design: Retrospective cohort study. Setting: Linked data from an ICD registry, heart failure registry, and Medicare claims data for ICDs implanted in 2005 through 2009. Participants: 29 426 patients admitted to hospital with heart failure aged 66 years or older and eligible for ICD therapy for primary prevention. Main outcome measures Non-traumatic hip fracture, admission to a skilled nursing facility, and 30 day mortality—outcomes unlikely to be improved by ICD therapy. Results: Compared with 17 853 patients without ICD therapy, 11 573 patients with ICD therapy were younger and had lower ejection fraction and more cardiac admissions to hospital but fewer non-cardiac admissions to hospital and comorbid conditions. Patients with ICD therapy had greater freedom from unrelated events after adjusting for age and sex: hip fracture (hazard ratio 0.77, 95% confidence interval 0.64 to 0.92), skilled nursing facility admission (0.53, 0.50 to 0.55), and 30 day mortality (0.12, 0.10 to 0.15). Conclusions: Lower risks of measured outcomes likely reflect unmeasured differences in comorbidity and frailty. The findings highlight potential pitfalls of observational comparative effectiveness research and support physician consideration of general health status in selecting patients for ICD therapy.

Description

Research Data

Keywords

Terms of Use

This article is made available under the terms and conditions applicable to Other Posted Material (LAA), as set forth at Terms of Service

Endorsement

Review

Supplemented By

Related Stories