Publication:

Accelerated free breathing ECG triggered contrast enhanced pulmonary vein magnetic resonance angiography using compressed sensing

Loading...
Thumbnail Image

Open/View Files

Date

2014

Journal Title

Journal ISSN

Volume Title

Publisher

BioMed Central
The Harvard community has made this article openly available. Please share how this access benefits you.

Research Projects

Organizational Units

Journal Issue

Citation

Roujol, Sébastien, Murilo Foppa, Tamer A Basha, Mehmet Akçakaya, Kraig V Kissinger, Beth Goddu, Sophie Berg, and Reza Nezafat. 2014. “Accelerated free breathing ECG triggered contrast enhanced pulmonary vein magnetic resonance angiography using compressed sensing.” Journal of Cardiovascular Magnetic Resonance 16 (1): 91. doi:10.1186/s12968-014-0091-z. http://dx.doi.org/10.1186/s12968-014-0091-z.

Abstract

Background: To investigate the feasibility of accelerated electrocardiogram (ECG)-triggered contrast enhanced pulmonary vein magnetic resonance angiography (CE-PV MRA) with isotropic spatial resolution using compressed sensing (CS). Methods: Nineteen patients (59 ± 13 y, 11 M) referred for MR were scanned using the proposed accelerated free breathing ECG-triggered 3D CE-PV MRA sequence (FOV = 340 × 340 × 110 mm3, spatial resolution = 1.5 × 1.5 × 1.5 mm3, acquisition window = 140 ms at mid diastole and CS acceleration factor = 5) and a conventional first-pass breath-hold non ECG-triggered 3D CE-PV MRA sequence. CS data were reconstructed offline using low-dimensional-structure self-learning and thresholding reconstruction (LOST) CS reconstruction. Quantitative analysis of PV sharpness and subjective qualitative analysis of overall image quality were performed using a 4-point scale (1: poor; 4: excellent). Results: Quantitative PV sharpness was increased using the proposed approach (0.73 ± 0.09 vs. 0.51 ± 0.07 for the conventional CE-PV MRA protocol, p < 0.001). There were no significant differences in the subjective image quality scores between the techniques (3.32 ± 0.94 vs. 3.53 ± 0.77 using the proposed technique). Conclusions: CS-accelerated free-breathing ECG-triggered CE-PV MRA allows evaluation of PV anatomy with improved sharpness compared to conventional non-ECG gated first-pass CE-PV MRA. This technique may be a valuable alternative for patients in which the first pass CE-PV MRA fails due to inaccurate first pass timing or inability of the patient to perform a 20–25 seconds breath-hold.

Description

Research Data

Keywords

Magnetic resonance angiography, Pulmonary vein, 3D acquisition, Acceleration techniques, Compressed sensing