Publication:
4D Graph-Based Segmentation for Reproducible and Sensitive Choroid Quantification From Longitudinal OCT Scans

Thumbnail Image

Open/View Files

Date

2016

Published Version

Journal Title

Journal ISSN

Volume Title

Publisher

The Association for Research in Vision and Ophthalmology
The Harvard community has made this article openly available. Please share how this access benefits you.

Research Projects

Organizational Units

Journal Issue

Citation

Oguz, Ipek, Michael D. Abramoff, Li Zhang, Kyungmoo Lee, Ellen Ziyi Zhang, and Milan Sonka. 2016. “4D Graph-Based Segmentation for Reproducible and Sensitive Choroid Quantification From Longitudinal OCT Scans.” Investigative Ophthalmology & Visual Science 57 (9): OCT621-OCT630. doi:10.1167/iovs.15-18924. http://dx.doi.org/10.1167/iovs.15-18924.

Research Data

Abstract

Purpose Longitudinal imaging is becoming more commonplace for studies of disease progression, response to treatment, and healthy maturation. Accurate and reproducible quantification methods are desirable to fully mine the wealth of data in such datasets. However, most current retinal OCT segmentation methods are cross-sectional and fail to leverage the inherent context present in longitudinal sequences of images. Methods: We propose a novel graph-based method for segmentation of multiple three-dimensional (3D) scans over time (termed 3D + time or 4D). The usefulness of this approach in retinal imaging is illustrated in the segmentation of the choroidal surfaces from longitudinal optical coherence tomography (OCT) scans. A total of 3219 synthetic (3070) and patient (149) OCT images were segmented for validation of our approach. Results: The results show that the proposed 4D segmentation method is significantly more reproducible (P < 0.001) than the 3D approach and is significantly more sensitive to temporal changes (P < 0.0001) achieved by the substantial increase of measurement robustness. Conclusions: This is the first automated 4D method for jointly quantifying choroidal thickness in longitudinal OCT studies. Our method is robust to image noise and produces more reproducible choroidal thickness measurements than a sequence of independent 3D segmentations, without sacrificing sensitivity to temporal changes.

Description

Keywords

image segmentation, choroid, OCT, multilayered graph search

Terms of Use

This article is made available under the terms and conditions applicable to Other Posted Material (LAA), as set forth at Terms of Service