Publication: Accuracy of CT Colonography for Detection of Polypoid and Nonpolypoid Neoplasia by Gastroenterologists and Radiologists: A Nationwide Multicenter Study in Japan
Open/View Files
Date
2017
Published Version
Journal Title
Journal ISSN
Volume Title
Publisher
Nature Publishing Group
The Harvard community has made this article openly available. Please share how this access benefits you.
Citation
Nagata, K., S. Endo, T. Honda, T. Yasuda, M. Hirayama, S. Takahashi, T. Kato, et al. 2017. “Accuracy of CT Colonography for Detection of Polypoid and Nonpolypoid Neoplasia by Gastroenterologists and Radiologists: A Nationwide Multicenter Study in Japan.” The American Journal of Gastroenterology 112 (1): 163-171. doi:10.1038/ajg.2016.478. http://dx.doi.org/10.1038/ajg.2016.478.
Research Data
Abstract
OBJECTIVES: The objective of this study was to assess prospectively the diagnostic accuracy of computer-assisted computed tomographic colonography (CTC) in the detection of polypoid (pedunculated or sessile) and nonpolypoid neoplasms and compare the accuracy between gastroenterologists and radiologists. METHODS: This nationwide multicenter prospective controlled trial recruited 1,257 participants with average or high risk of colorectal cancer at 14 Japanese institutions. Participants had CTC and colonoscopy on the same day. CTC images were interpreted independently by trained gastroenterologists and radiologists. The main outcome was the accuracy of CTC in the detection of neoplasms ≥6 mm in diameter, with colonoscopy results as the reference standard. Detection sensitivities of polypoid vs. nonpolypoid lesions were also evaluated. RESULTS: Of the 1,257 participants, 1,177 were included in the final analysis: 42 (3.6%) were at average risk of colorectal cancer, 456 (38.7%) were at elevated risk, and 679 (57.7%) had recent positive immunochemical fecal occult blood tests. The overall per-participant sensitivity, specificity, and positive and negative predictive values for neoplasms ≥6 mm in diameter were 0.90, 0.93, 0.83, and 0.96, respectively, among gastroenterologists and 0.86, 0.90, 0.76, and 0.95 among radiologists (P<0.05 for gastroenterologists vs. radiologists). The sensitivity and specificity for neoplasms ≥10 mm in diameter were 0.93 and 0.99 among gastroenterologists and 0.91 and 0.98 among radiologists (not significant for gastroenterologists vs. radiologists). The CTC interpretation time by radiologists was shorter than that by gastroenterologists (9.97 vs. 15.8 min, P<0.05). Sensitivities for pedunculated and sessile lesions exceeded those for flat elevated lesions ≥10 mm in diameter in both groups (gastroenterologists 0.95, 0.92, and 0.68; radiologists: 0.94, 0.87, and 0.61; P<0.05 for polypoid vs. nonpolypoid), although not significant (P>0.05) for gastroenterologists vs. radiologists. CONCLUSIONS: CTC interpretation by gastroenterologists and radiologists was accurate for detection of polypoid neoplasms, but less so for nonpolypoid neoplasms. Gastroenterologists had a higher accuracy in the detection of neoplasms ≥6 mm than did radiologists, although their interpretation time was longer than that of radiologists.
Description
Other Available Sources
Keywords
Terms of Use
This article is made available under the terms and conditions applicable to Other Posted Material (LAA), as set forth at Terms of Service