Publication: Reduced exposure using asymmetric cone beam processing for wide area detector cardiac CT
Open/View Files
Date
2011
Published Version
Journal Title
Journal ISSN
Volume Title
Publisher
Springer Nature
The Harvard community has made this article openly available. Please share how this access benefits you.
Citation
Bedayat, Arash, Frank J. Rybicki, Kanako Kumamaru, Sara L. Powers, Jason Signorelli, Michael L. Steigner, Chloe Steveson, et al. 2011. “Reduced Exposure Using Asymmetric Cone Beam Processing for Wide Area Detector Cardiac CT.” The International Journal of Cardiovascular Imaging 28 (2) (February 19): 381–388. doi:10.1007/s10554-011-9814-5.
Research Data
Abstract
The purpose of this study was to estimate dose reduction after implementation of asymmetrical cone beam processing using exposure differences measured in a water phantom and a small cohort of clinical coronary CTA patients. Two separate 320 × 0.5 mm detector row scans of a water phantom used identical cardiac acquisition parameters before and after software modifications from symmetric to asymmetric cone beam acquisition and processing. Exposure was measured at the phantom surface with Optically Stimulated Luminescence (OSL) dosimeters at 12 equally spaced angular locations. Mean HU and standard deviation (SD) for both approaches were compared using ROI measurements obtained at the center plus four peripheral locations in the water phantom. To assess image quality, mean HU and standard deviation (SD) for both approaches were compared using ROI measurements obtained at five points within the water phantom. Retrospective evaluation of 64 patients (37 symmetric; 27 asymmetric acquisition) included clinical data, scanning parameters, quantitative plus qualitative image assessment, and estimated radiation dose. In the water phantom, the asymmetric cone beam processing reduces exposure by approximately 20% with no change in image quality. The clinical coronary CTA patient groups had comparable demographics. The estimated dose reduction after implementation of the asymmetric approach was roughly 24% with no significant difference between the symmetric and asymmetric approach with respect to objective measures of image quality or subjective assessment using a four point scale. When compared to a symmetric approach, the decreased exposure, subsequent lower patient radiation dose, and similar image quality from asymmetric cone beam processing supports its routine clinical use.
Description
Other Available Sources
Keywords
Coronary imaging, Computed tomography, Angiography, Image reconstruction, Radiation dose